Lab.gruppen iP Series IP 450 Скачать руководство пользователя страница 14

V= molqb`qflk=cb^qrobp=

Each Lab.gruppen amplifier has many advanced protection features, protecting both the amplifier and the 
speakers connected to it should a fault condition arise. Under normal use these features are inaudible. All 
protection circuits are independent. 

VKNKN= `äáé=iáãáíÉê=

The clip limiter is included to prevent from dangerous clipped signals reaching the speaker and damaging 
it. If an amplifier is severely overdriven, its output waveform is clipped (its peaks are squared off) –
reducing the crest factor. In extreme cases the waveform can approach that of a square wave. An amplifier 
is normally capable of producing far more power under these conditions than its normal undistorted rated 
output power. 
The limiter works by monitoring the output and comparing the distortion produced between the input and 
output of the amplifier. If the distortion exceeds 1% THD for any reason (voltage or current clipping), the 
limiter reduces the input signal proportionally. Note that, if the signal is distorted or clipped before it 
reaches the amplifier, the clip limiter cannot detect it, and will not be activated. 
During normal operation the clip limiting is inaudible. The limiter can be turned on or off by using the 
relevant clip limit switch. Note that in Bridge mode the limiters of both channels should be in the same 
position, either on or off. 
Some manufacturers of loudspeaker controllers do not recommend the use of clip limiters in amplifiers, as 
they tend to upset the tracking of the controller’s limiters. 
Apart from this single exception, Lab.gruppen

 

recommend to leave the clip limiters switched "on" (button 

depressed). As a side-effect, once the amplifier comes out of a protect condition, the output level has a 
slow rise time – the effect is like turning up the gain slowly. 

VKNKO= qÜÉêã~ä=éêçíÉÅíáçå=

If the amplifier is driven very hard into a low impedance load, the temperature will rise. If the causing 
conditions continue, the Protection indicator(s) will illuminate indicating that the amplifier is about to go 
into thermal shutdown. 
After five seconds the amplifier will go into thermal protection by muting the input signal. After some 
time the amplifier will have cooled down enough for the amplifier to come out of shutdown and operate as 
normal. If the load conditions remain unchanged the thermal protection will be reinitiated. Thermal 
protection starts when the heatsink reaches a temperature above 90

0

 C. 

VKNKP= sec=éêçíÉÅíáçå=

If a signal above 12kHz is detected at the amplifier outputs for more than five seconds at full output 
power, the VHF protection mutes the input signal. (This is indicated on the front panel labeled Protect). 
After five seconds the outputs will un-mute and return to normal operation, unless the output signal has 
remained unchanged, in which case the VHF protection will re-initiate. 

VKNKQ= pÜçêí=ÅáêÅìáí=éêçíÉÅíáçå=

All Lab.gruppen amplifiers are completely short circuit protected. The protection circuit permits very 
high peak currents, but still holds the output devices within the safe operation area. If a short circuit is 
maintained, the channel affected will eventually go into thermal protect cycle until the short circuit has 
been removed.  

VKNKR= aK`K=éêçíÉÅíáçå=

There are two types of DC protection: 

• 

Fuses on the supply branches of each channel. 

• 

A DC crowbar protection that shorts the output if more than 10 volts DC are being detected on the 
outputs. 

Either of these protections comes into effect once DC voltage is being detected, independently for both 
channels. 

i~ÄKÖêìééÉå== =

=

=

=

=

========================

NP

 

rëÉê=j~åì~ä===ám=QRM======sÉêëáçå=MKP========OMMPJMOJOR=

Содержание iP Series IP 450

Страница 1: ...m QRM rpbo j kr i...

Страница 2: ...5 3 3 Tandem mode 7 5 3 4 Bridge mono mode 7 5 3 5 Bridge mono mode features 7 6 INSTALLATION 8 6 1 Mounting 8 6 2 Cooling 8 6 3 Operating voltage 8 6 4 Grounding 8 6 5 Power consumption 9 6 5 1 Calc...

Страница 3: ...nding in liquid 5 Clean only with dry cloth 6 Do not block the cooling fins Install the unit in accordance with the instructions 7 Do not operate the amplifier near heat producing devices such as radi...

Страница 4: ...any exposed speaker wiring while the amplifier is operating See page 11 hock about outputs for proper connection of speakers PKRKP o A sample of this product has been tested and complies with the limi...

Страница 5: ...the amplifier They are calibrated in dB to assist the setup of active loudspeaker systems or cut down unwanted noise from the input signal See page 12 3 Clip limit indicator This indicator signals whe...

Страница 6: ...to make sure that the unit is set up properly for your specific application RKN d The gain switch located on the rear panel the central DIP switch changes the input sensitivity of the amplifier This...

Страница 7: ...ecessed one can put a sticker across the bay and prevent from unauthorized changes Another option is to remove the DIP switch This should be done by authorized service personnel only This corresponds...

Страница 8: ...the remaining input connectors to carry signal to other amps Both level attenuators must be at the same position We recommend that you put them in the 0dB full position Connect the speaker as shown Al...

Страница 9: ...o the AC source referred to on the label The warranty will not cover damage caused by connecting to the wrong type of AC mains If the power plug is not appropriate for your country it can be cut off a...

Страница 10: ...completely obliterating the program Last the regular operating power as defined by the safety standard IEC 65 ANSI UL 6500 and used by a majority of safety agencies The regular operating power is meas...

Страница 11: ...nd wired in the following way PIN 1 GROUND SHIELD PIN 2 HOT PIN 3 COLD Figure 4 XLR input connector Figure 5 XLR balanced Within the Neutrik Combojack there is a 6 3mm phone jack which is wired in par...

Страница 12: ...d prevents from shock hazard They are wired in the following manner The right jack Channel A has both channel A and B outputs so it s useful for bridging and bi amp operation see bridged mono operatio...

Страница 13: ...input level attenuators on the front panel adjust the signal level for their respective amplifier channel in all modes They are calibrated in dB to help setting up active loudspeaker systems or cutti...

Страница 14: ...once the amplifier comes out of a protect condition the output level has a slow rise time the effect is like turning up the gain slowly VKNKO q If the amplifier is driven very hard into a low impedan...

Страница 15: ...e high frequency oscillations from the relevant input Fault The amplifier goes into thermal protection when driven at low level Check that nothing causes a short circuit at the amplifier s output e g...

Страница 16: ...NN pmb fcf qflkp i K NR r j m QRM s MKP OMMPJMOJOR...

Страница 17: ...sibility for any loss due to cancellation of any events or rent of replacement equipment or costs due to third party s or customer s loss of profit or any other indirect cost or losses however incurre...

Отзывы: