Lab.gruppen iP 2100 Скачать руководство пользователя страница 9

RKPKR= _êáÇÖÉ=ãçåç=ãçÇÉ=ÑÉ~íìêÉë=

Bridged mono mode combines the power of both channels into one speaker. This results in twice the 
voltage swing, four times the peak power and just less than three times the full power of a single 
channel. 
 
One way to understand the load and power from the amplifier’s perspective in bridged mode is that it is 
zero voltage at the center of the voice-coil winding. This is because the coil is driven with positive 
voltage at one pole and an equivalent negative voltage at the other pole. So, if an 8 ohms load is 
connected in bridged mode, one channel shares one 4 ohms part of the load, and the other channel 
shares the other 4 ohms part. The power into 4 ohms from an iP 2100 is 700W. So, the total bridged 
power into the 8 ohms load will be 2 x 700 = 1400W 

 

S= fkpq^ii^qflk=

SKN= jçìåíáåÖ=

The amplifier is two rack units high (2U) and will mount in a standard EIA 19” rack. Amplifiers may be 
stacked directly on top of each other. There is no need for spacing between units. If it is the intention to 
fill a rack with amplifiers, we recommend racking is started from the bottom of the rack. It is also 
recommended that rear supports are used for amplifiers mounted in the middle of the rack, especially if 
used as part of a portable system. 

SKO= `ççäáåÖ=

Your amplifier uses a forced air cooling system to maintain a low and even operating temperature. All 
fan cooled Lab.gruppen amplifiers have front to rear airflow. There are several reasons for this, one 
being that there is usually cooler air outside the rack than inside, and therefore the amplifiers can run at 
higher continuous power levels without thermal problems. Never try to reverse the airflow, as the 
Intercooler® needs a pressure chamber between the fans and heat sink, and this only works in one 
direction of the airflow.

 

Should a heat sink get too hot, its sensing circuit will mute the hot channel. If the power supply 
overheats, another sensing circuit will mute all output channels, until it cools down to a safe operating 
temperature. 
Make sure that there is an adequate air supply in front of the amplifier, and that the rear of the amplifier 
has sufficient space to allow the exhaust to escape. If the amplifier is rack-mounted, do not use covers 
or doors on the front or rear of the rack.  
For installations with a central cooling system, usually found in fixed installations with a dedicated rack 
room, it may be necessary to calculate the maximum heat emission. Refer to Power consumption on 
page 

9

 

SKP= léÉê~íáåÖ=îçäí~ÖÉ=

WARNING! 

A label just below the mains cable on the rear of the amplifier indicates the AC mains 
voltage, for which the amplifier is wired. Connect the power cable only to the AC source 

!

i~ÄKÖêìééÉå== =

=

=

=

=

========================

U

 

rëÉê=j~åì~ä===ám=ONMM====sÉêëáçå=MKP======OMMPJMOJOR=

Содержание iP 2100

Страница 1: ...m ONMM rpbo j kr i...

Страница 2: ...7 5 3 4 Bridge mono mode 7 5 3 5 Bridge mono mode features 8 6 INSTALLATION 8 6 1 Mounting 8 6 2 Cooling 8 6 3 Operating voltage 8 6 4 Denmark 9 6 5 Grounding 9 6 6 Power consumption 9 6 6 1 Calculati...

Страница 3: ...ings 3 Follow all instructions 4 Do not use this unit near water Do not spill water or other liquids into or on the unit Do not operate the amplifier while wet or standing in liquid 5 Clean only with...

Страница 4: ...l output power if the input signal level is high enough PKRKO p Power amplifiers are capable of producing hazardous output voltages To avoid electrical s do not touch any exposed speaker wiring while...

Страница 5: ...ator This indicator illuminates if the amplifier tries to operate above its maximum operating temperature 90 C The indicator first comes on as a warning to either turn down the input level or check th...

Страница 6: ...or off switch OUT position See page 13 4 Input signal XLR Neutrik Combojack features also TRS phone jacks Pin 2 is hot see page 10 5 Link Output 3 pole screw terminal of Phoenix brand Connected in par...

Страница 7: ...to 41dB in 3dB steps See the different settings for the DIP switches in the table below The three switches to the very left are for channel B and the three to the very right are for channel A RKNKO p...

Страница 8: ...illoscope probes if you are bench testing Reverse operation of Channel B RKPKP q In tandem mode both channels inputs are linked and receive the same signal The tandem mode is active if the Link switch...

Страница 9: ...Your amplifier uses a forced air cooling system to maintain a low and even operating temperature All fan cooled Lab gruppen amplifiers have front to rear airflow There are several reasons for this one...

Страница 10: ...filter This filter needs the chassis ground for reference otherwise a current loop is formed via the signal ground Use the balanced input to avoid hum and interference SKS m There are three ways to d...

Страница 11: ...5dB 1 3 of full power and a producing 700 watts per channel The 1 3 power per channel is accordingly 700 3 233 5 watts and total output 2 x 233 5 467 watts The power consumption according power consu...

Страница 12: ...provided on each channel It is connected in parallel with the Neutrik Combo jack on each input TKNKO r To connect an unbalanced input source connect pins 1 and 3 in the cable s XLR plug ring and sleev...

Страница 13: ...r that the speaker cable robs the power of the amplifiers in two ways by increasing the load impedance and by introducing resistive power losses WARNING To prevent from electric shock do not operate t...

Страница 14: ...e features are inaudible All protection circuits are independent VKNKN i The clip limiter is included to prevent from dangerous clipped signals reaching the speaker and damaging it If an amplifier is...

Страница 15: ...nds the outputs will un mute and return to normal operation unless the output signal has remained unchanged in which case the VHF protection will re initiate VKNKQ p All Lab gruppen amplifiers are com...

Страница 16: ...rotection is not activated If it is remove possible high frequency oscillations from the relevant input Fault The amplifier goes into thermal protection when driven at low level Check that nothing cau...

Страница 17: ...NN pmb fcf qflkp i K NS r j m ONMM s MKP OMMPJMOJOR...

Страница 18: ...sibility for any loss due to cancellation of any events or rent of replacement equipment or costs due to third party or customer s loss of profit or any other indirect cost or losses however incurred...

Отзывы: