Thank you for purchasing a Lab.gruppen power amplifier. This manual contains important information 
on operating your amplifier correctly and safely. Please take some time and read this manual to 
familiarize you with the advanced features of this amplifier. 

QKN= råé~ÅâáåÖ=

Carefully open the shipping carton and check for any noticeable damage. Every Lab.gruppen amplifier 
is tested and inspected before leaving the factory and should arrive in perfect condition. If found to be 
damaged, notify the shipping company immediately. Only the consignee may institute a claim with the 
carrier for damage incurred during shipping. Be sure to save the carton and packing materials for the 
carrier's inspection. 
It is also advisable to save the carton and packing material, even if the amplifier is undamaged. Should 
you ever need to ship the amplifier, always use the original packing. 

QKO= cêçåí=m~åÉä=

Figure 1 front panel 
 

1

. Input level attenuators 

These controls are used to alter the signal level entering the amplifier. They are calibrated in dB to assist 
the setup of active loudspeaker systems or cut down unwanted noise from the input signal. (See page 

13

). 

 

2. Protect indicator 

This indicator illuminates if the amplifier tries to operate above its maximum operating temperature 
(90°

°

C). The indicator first comes on as a warning to either turn down the input level or check the 

cooling arrangements. Beyond the maximum temperature the amplifier will mute the input signal. Once 
the cooling fans have brought the output heat sinks back to normal operating temperature the input 
signal is un-muted. 
This indicator also illuminates when signals above 12 kHz are continuously present at full power at the 
output terminals or if short circuit protection is activated. If this occurs the input signal is muted, and the 
process cycles until the VHF signal is no longer present or the short is removed. (See page 

14

). 

 
3. Clip/limit indicator 

This indicator signals when the amplifier output is clipping or limiting. It has two different indication 
states: 
If the clip limiter is engaged, it has a short time constant and it illuminates briefly. (See page 

13

). 

If the clip limiter is not engaged, it has an increased time constant and it illuminates for a longer period.  

 
4. Signal present indicator.  

Illuminates at –40dB below full output signal. 
 

5. On indicator 

The two bottom green ”ON” LEDs indicate that the output circuits are receiving the correct rail voltage. 

 
6. Power switch 

Turns mains power on or off.  
(See page 

8

 and 

12

)

 

i~ÄKÖêìééÉå== =

=

=

=

=

========================

Q

 

rëÉê=j~åì~ä===ám=ONMM====sÉêëáçå=MKP======OMMPJMOJOR=

Содержание iP 2100

Страница 1: ...m ONMM rpbo j kr i...

Страница 2: ...7 5 3 4 Bridge mono mode 7 5 3 5 Bridge mono mode features 8 6 INSTALLATION 8 6 1 Mounting 8 6 2 Cooling 8 6 3 Operating voltage 8 6 4 Denmark 9 6 5 Grounding 9 6 6 Power consumption 9 6 6 1 Calculati...

Страница 3: ...ings 3 Follow all instructions 4 Do not use this unit near water Do not spill water or other liquids into or on the unit Do not operate the amplifier while wet or standing in liquid 5 Clean only with...

Страница 4: ...l output power if the input signal level is high enough PKRKO p Power amplifiers are capable of producing hazardous output voltages To avoid electrical s do not touch any exposed speaker wiring while...

Страница 5: ...ator This indicator illuminates if the amplifier tries to operate above its maximum operating temperature 90 C The indicator first comes on as a warning to either turn down the input level or check th...

Страница 6: ...or off switch OUT position See page 13 4 Input signal XLR Neutrik Combojack features also TRS phone jacks Pin 2 is hot see page 10 5 Link Output 3 pole screw terminal of Phoenix brand Connected in par...

Страница 7: ...to 41dB in 3dB steps See the different settings for the DIP switches in the table below The three switches to the very left are for channel B and the three to the very right are for channel A RKNKO p...

Страница 8: ...illoscope probes if you are bench testing Reverse operation of Channel B RKPKP q In tandem mode both channels inputs are linked and receive the same signal The tandem mode is active if the Link switch...

Страница 9: ...Your amplifier uses a forced air cooling system to maintain a low and even operating temperature All fan cooled Lab gruppen amplifiers have front to rear airflow There are several reasons for this one...

Страница 10: ...filter This filter needs the chassis ground for reference otherwise a current loop is formed via the signal ground Use the balanced input to avoid hum and interference SKS m There are three ways to d...

Страница 11: ...5dB 1 3 of full power and a producing 700 watts per channel The 1 3 power per channel is accordingly 700 3 233 5 watts and total output 2 x 233 5 467 watts The power consumption according power consu...

Страница 12: ...provided on each channel It is connected in parallel with the Neutrik Combo jack on each input TKNKO r To connect an unbalanced input source connect pins 1 and 3 in the cable s XLR plug ring and sleev...

Страница 13: ...r that the speaker cable robs the power of the amplifiers in two ways by increasing the load impedance and by introducing resistive power losses WARNING To prevent from electric shock do not operate t...

Страница 14: ...e features are inaudible All protection circuits are independent VKNKN i The clip limiter is included to prevent from dangerous clipped signals reaching the speaker and damaging it If an amplifier is...

Страница 15: ...nds the outputs will un mute and return to normal operation unless the output signal has remained unchanged in which case the VHF protection will re initiate VKNKQ p All Lab gruppen amplifiers are com...

Страница 16: ...rotection is not activated If it is remove possible high frequency oscillations from the relevant input Fault The amplifier goes into thermal protection when driven at low level Check that nothing cau...

Страница 17: ...NN pmb fcf qflkp i K NS r j m ONMM s MKP OMMPJMOJOR...

Страница 18: ...sibility for any loss due to cancellation of any events or rent of replacement equipment or costs due to third party or customer s loss of profit or any other indirect cost or losses however incurred...

Отзывы: