Lab.gruppen fP Series FP 6400 Скачать руководство пользователя страница 5

If this equipment does cause harmful interference to radio or television reception, which can be 
determined by turning the equipment on and off, the user is encouraged to try to correct the interference 
by one or more of the following measures: 

• 

Reorient or relocate the antenna. 

• 

Increase the separation between the equipment and receiver. 

• 

Connect the equipment into an outlet on a circuit different from that to which the receiver is 
connected. 

• 

Check if the affected unit complies with the EMC limits for immunity, (CE-labelled). If not, 
address the problem with the manufacturer or supplier. All electrical products sold in the 
EC must be approved for immunity against electromagnetic fields, high voltage flashes, and 
radio interference. 

• 

Consult the dealer or an experienced radio/TV technician for help. 

Q= fkqolar`qflk=

Thank you for purchasing a Lab.gruppen power amplifier. This manual contains important information 
on operating your amplifier correctly and safely. Please take some time and read this manual to 
familiarize you with the advanced features of this amplifier. 

QKN= råé~ÅâáåÖ=

Carefully open the shipping carton and check for any noticeable damage. Every Lab.gruppen amplifier 
is tested and inspected before leaving the factory and should arrive in perfect condition. If found to be 
damaged, notify the shipping company immediately. Only the consignee may institute a claim with the 
carrier for damage incurred during shipping. Be sure to save the carton and packing materials for the 
carrier's inspection. 
It is also advisable to save the carton and packing material, even if the amplifier is undamaged. Should 
you ever need to ship the amplifier, always use the original packing. 

QKO= cêçåí=m~åÉä=

VHF

CLIP

-5dB

ON

CH.A

-80

-40

-20

-16

-12

-10

-7

-5

-3

-1

0

dB

-3

-1

0

dB

CH.B

-10dB
-15dB

-20dB
-25dB

TEMP

CONVERTIBLE POWER AMPLIFIER

AFS

AC

7

2

2

1

6

3 4

5

6

8 9

Figure 1: Front panel 
 

1. Carry/protection handle 

Both handles can be used to carry the amplifier; they also act as protection for the front panel. In 
permanent installations, or where rack front covers are too shallow they may be removed by unscrewing 
the retaining bolts behind the front panel. 
 

2. Input level attenuators 

These controls are used to alter the signal level entering the amplifier. They are calibrated in dB to assist 
the setup of active loudspeaker systems, or to cut down unwanted noise from the input signal. (See page 

15

 

3. Over temperature protect indicator 

This indicator illuminates if the amplifier is going to operate above its maximum operating temperature 
(90°

°

C). The indicator first comes on as a warning to either turn down the input level or check the 

cooling arrangements. Beyond the maximum temperature the amplifier will mute the input signal. Once 
the cooling fans have brought the output heat sinks back to normal operating temperature the input 
signal is un-muted. 

i~ÄKÖêìééÉå== =

=

=

=

=

========================

Q

 

rëÉê=j~åì~ä===Ñm=SQMM======sÉêëáçå=NKN========OMMPJNMJMO=

Содержание fP Series FP 6400

Страница 1: ...m SQMM rpbo j kr i...

Страница 2: ...mode 8 5 3 5 Bridge mono mode features 8 5 4 Impedance matching MLS switch 8 5 4 1 A practical way to find your MLSTM settings 9 5 4 2 MLS technology the background 10 5 4 3 The problem 10 5 4 4 The...

Страница 3: ...ed dangerous voltage within the amplifier s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to humans The exclamation point within a triangle is intended to alert...

Страница 4: ...The unit has been exposed to rain or moisture The unit does not operate normally The unit was dropped or the enclosure is damaged 17 Do not remove top or bottom covers Removal of the cover will expos...

Страница 5: ...y Only the consignee may institute a claim with the carrier for damage incurred during shipping Be sure to save the carton and packing materials for the carrier s inspection It is also advisable to sa...

Страница 6: ...e used 7 Power switch Turns mains power on or off See page 11 and 14 8 AC indicator Indicates if AC voltage is present Note Electrically this indicator is located in front of the power switch 9 AFS in...

Страница 7: ...utput and or crossover units In an actively divided system there is very often a so called loudspeaker processor or controller involved it being unique for the loudspeaker system In most cases the man...

Страница 8: ...polarity reversed on the input but polarity compensated by feeding the minus pin on the Channel B output with the output voltage Channel A output is connected in normal polarity mode By having channel...

Страница 9: ...res the other 4 ohms part The power into 4 ohms from an fP 6400 MLS at 0dB is 2300 watts So the total bridged power into an 8 ohms load will be 2 x 2300 4600 watts RKQ f Ejip F The MLSTM switches are...

Страница 10: ...amp mode 3200 2 2300 4 2300 4 1300 8 1300 8 650 16 2300 4 830 4 Table 2 1 Check if the loudspeaker can take the amp s maximum output power generally twice the RMS power handling should be okay 2 If t...

Страница 11: ...justed for a much higher current so it cannot interfere with the requirements by the loudspeaker impedance curve S fkpq ii qflk SKN j The amplifier is two rack units high 2U and will fit into a standa...

Страница 12: ...ty regulation stipulates that a mains connector of the type 23 must be used SKS d There is no ground lift switch or terminal on this amplifier The signal ground is always floating via a resistor to ch...

Страница 13: ...KTKN e calculated as in the following example 4 ohms load on an amplifier tts and to the chart above is then 1975 watts This chart shows the active he heat power produced is the difference between the...

Страница 14: ...ss in long cables To daisy chain amplifiers use the XLR male connector provided on each channel labeled Link They are connected in parallel with the Neutrik Combojack on each input TKNKO r To connect...

Страница 15: ...r of the amplifiers in two ways by increasing the load impedance and by introducing resistive power losses WARNING To prevent from electrical shock do not operate the amplifier with any portion of the...

Страница 16: ...tures are inaudible All protection circuits work independent from each other VKNKN The clip limiter is included to prevent from dangerous clipped signals reaching the speaker and damaging it If an amp...

Страница 17: ...for its presence is to avoid blowing the mains breaker if a bench test is made at continuous full power The AFSTM circuitry is a current limiter limiting the mains power current draw to 20A 230V or 40...

Страница 18: ...u are using your amplifier for heavy duty use i e for concert touring or with industrial music it is recommended to have your amplifier serviced every 3 years purely as a preventative measure NMKN q T...

Страница 19: ...NN pmb fcf qflkp i K NU r j m SQMM s NKN OMMPJNMJMO...

Страница 20: ...ibility for any loss due to cancellation of any events or rent of replacement equipment or costs due to third party s or customer s loss of profit or any other indirect cost or losses however incurred...

Отзывы: