WARNING! 
A label just below the mains cable on the rear of the amplifier indicates the AC mains voltage for 
which the amplifier is wired. Connect the power cable only to the AC source referred to on the 
label. The warranty will not cover damage caused by connecting to the wrong type of AC mains. 

 
Lab.gruppen switch mode amplifiers use primary switching. The mains power is being rectified directly 
in front of the transformer, meaning that the power supply is insensitive to the mains frequency and will 
operate from DC to 400 Hz. 
If the power plug is not appropriate for your country, it can be cut off and wired to a suitable connector in 
the following way: 
 

BLACK or BROWN 

 

LIVE 

 
WHITE or BLUE 

 

NEUTRAL 

 
GREEN or GREEN/YELLOW 

EARTH 

 
Once the AC connector is connected to a suitable AC supply, the amplifier can be started with the power 
switch. When you power up the amplifier it takes a couple of seconds to check its circuits (this is known 
as the "soft start" or "slow start" sequence), the fans then blow at high speed before going into "idle", and 
the two bottom green LED’s come on to show the output circuits are receiving the correct rail voltage. 

SKQ= aÉåã~êâ=

National deviation concerning installation of the fP 6400: 
Danish safety regulation only permits 8A main fuses. As the fP 6400 uses an internal primary mains 
fuse of 15A, the fP 6400 must be equipped with an industrial mains connector rated for 16A, or as an 
alternative be permanently installed to a 16A circuit. 

SKR= pïáíòÉêä~åÇ=

National deviation concerning installation of the fP 6400: 
Swiss safety regulation stipulates that a mains connector of the type 23 must be used. 

SKS= dêçìåÇáåÖ=

There is no ground lift switch or terminal on this amplifier. The signal ground is always floating via a 
resistor to chassis, and the grounding system is automatic. If a potential above 0.6V is presents in between 
signal ground and chassis ground, a short circuit is introduced between the two, thereby enabling electrical 
protection. If a unit in the system is faulty, its mains fuse will blow due to this automatic ground system. 
If however you wish to tie the signal ground to chassis, connect the XLR-connector’s shell lug to pin 1. In 
the interest of safety never disconnect the earth pin on the AC power cord. 
For all units that are CE or FCC approved (radio interference), there is an AC mains filter. This filter 
needs the chassis ground for reference, otherwise a current loop is formed via the signal ground. 
Use the balanced input to avoid hum and interference. 

SKT= mçïÉê=Åçåëìãéíáçå=

There are three ways to determine the power/current consumption of the amplifier:  

First

, the peak current draw at full output power. Under this condition the power will blow the mains 

breaker within 30 seconds, or the amplifier will operate for less than 2 minutes before thermally 
limiting. Therefore it is meaningless to state the input power at full power. The heat power at full power 
will anyway be limited by the protection circuits. There is no audio program material producing steadily 
full output power; it would be only sine wave for test purposes.  
In case of the amplifier being operated at sustained full power (such as sine wave) into low impedances, 
the fP 6400 offers a mains current limiter called 

AFS

TM

 (Automatic Fuse Saver)

,

 

which will limit the 

i~ÄKÖêìééÉå== =

=

=

=

=

========================

NN

 

rëÉê=j~åì~ä===Ñm=SQMM======sÉêëáçå=NKN========OMMPJNMJMO=

Содержание fP Series FP 6400

Страница 1: ...m SQMM rpbo j kr i...

Страница 2: ...mode 8 5 3 5 Bridge mono mode features 8 5 4 Impedance matching MLS switch 8 5 4 1 A practical way to find your MLSTM settings 9 5 4 2 MLS technology the background 10 5 4 3 The problem 10 5 4 4 The...

Страница 3: ...ed dangerous voltage within the amplifier s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to humans The exclamation point within a triangle is intended to alert...

Страница 4: ...The unit has been exposed to rain or moisture The unit does not operate normally The unit was dropped or the enclosure is damaged 17 Do not remove top or bottom covers Removal of the cover will expos...

Страница 5: ...y Only the consignee may institute a claim with the carrier for damage incurred during shipping Be sure to save the carton and packing materials for the carrier s inspection It is also advisable to sa...

Страница 6: ...e used 7 Power switch Turns mains power on or off See page 11 and 14 8 AC indicator Indicates if AC voltage is present Note Electrically this indicator is located in front of the power switch 9 AFS in...

Страница 7: ...utput and or crossover units In an actively divided system there is very often a so called loudspeaker processor or controller involved it being unique for the loudspeaker system In most cases the man...

Страница 8: ...polarity reversed on the input but polarity compensated by feeding the minus pin on the Channel B output with the output voltage Channel A output is connected in normal polarity mode By having channel...

Страница 9: ...res the other 4 ohms part The power into 4 ohms from an fP 6400 MLS at 0dB is 2300 watts So the total bridged power into an 8 ohms load will be 2 x 2300 4600 watts RKQ f Ejip F The MLSTM switches are...

Страница 10: ...amp mode 3200 2 2300 4 2300 4 1300 8 1300 8 650 16 2300 4 830 4 Table 2 1 Check if the loudspeaker can take the amp s maximum output power generally twice the RMS power handling should be okay 2 If t...

Страница 11: ...justed for a much higher current so it cannot interfere with the requirements by the loudspeaker impedance curve S fkpq ii qflk SKN j The amplifier is two rack units high 2U and will fit into a standa...

Страница 12: ...ty regulation stipulates that a mains connector of the type 23 must be used SKS d There is no ground lift switch or terminal on this amplifier The signal ground is always floating via a resistor to ch...

Страница 13: ...KTKN e calculated as in the following example 4 ohms load on an amplifier tts and to the chart above is then 1975 watts This chart shows the active he heat power produced is the difference between the...

Страница 14: ...ss in long cables To daisy chain amplifiers use the XLR male connector provided on each channel labeled Link They are connected in parallel with the Neutrik Combojack on each input TKNKO r To connect...

Страница 15: ...r of the amplifiers in two ways by increasing the load impedance and by introducing resistive power losses WARNING To prevent from electrical shock do not operate the amplifier with any portion of the...

Страница 16: ...tures are inaudible All protection circuits work independent from each other VKNKN The clip limiter is included to prevent from dangerous clipped signals reaching the speaker and damaging it If an amp...

Страница 17: ...for its presence is to avoid blowing the mains breaker if a bench test is made at continuous full power The AFSTM circuitry is a current limiter limiting the mains power current draw to 20A 230V or 40...

Страница 18: ...u are using your amplifier for heavy duty use i e for concert touring or with industrial music it is recommended to have your amplifier serviced every 3 years purely as a preventative measure NMKN q T...

Страница 19: ...NN pmb fcf qflkp i K NU r j m SQMM s NKN OMMPJNMJMO...

Страница 20: ...ibility for any loss due to cancellation of any events or rent of replacement equipment or costs due to third party s or customer s loss of profit or any other indirect cost or losses however incurred...

Отзывы: