Lab.gruppen fP Series FP 3400 Скачать руководство пользователя страница 16

UKP= fåéìí=~ííÉåì~íçêë=

The two input level attenuators on the front panel adjust the signal level for their respective amplifier 
channel in all modes. They are calibrated in dB to assist the setup of active loudspeaker systems, or to cut 
down unwanted noise from the input signal.

 

In bridge mode both controls must be in the same position, so that the speaker load will be shared equally 
between the channels.

 

UKQ= fåÇáÅ~íçêë=

 

The yellow LED’s indicate if any protection 
circuits are activated. The protections are 
described further below on this page (

15

). 

 
The

 Clip indicator

 tells if the amplifier output 

is clipping or limiting. It has two different 
indication statuses: 

• 

If the clip limiter is enabled, it has a short 
time constant, and it illuminates briefly. 

• 

If the clip limiter is disabled, it has an 
increased time constant, and it illuminates 
for a longer period. 

 
 

Front panel indicators 

 
The ”-25dB” LED’s illuminate if the output signal is greater than -25dB (with 0dB as reference to full 
output power). These LED’s also act as signal presence indicators.  
 
The rest of the green LED’s form a bar for output levels from -20dB to -5dB.  
 
The green bottom ”ON” LED’s indicate that the output circuits are receiving the correct rail voltage. 

V= molqb`qflk=cb^qrobp=

Each Lab.gruppen amplifier has many advanced protection features. Should a fault condition arise they are 
protecting both, the amplifier and the speakers connected to it. Under normal use these features are 
inaudible. All protection circuits work independent from each other. 

VKNKN= `äáé=äáãáíÉê=

The clip limiter is included to prevent from dangerous clipped signals reaching the speaker and damaging 
it. If an amplifier is severely overdriven, its output waveform is clipped (its peaks are squared off) –
reducing the crest factor. In extreme cases the waveform can approach that of a square wave. An amplifier 
is normally capable of producing far more power under these conditions than its normal undistorted rated 
output power. 
The limiter works by monitoring the output and comparing the distortion produced between the input and 
output of the amplifier. If the distortion exceeds 1% THD for any reason (voltage or current clipping), the 
limiter reduces the input signal proportionally. Note that, if the signal is distorted or clipped before it 
reaches the amplifier, the clip limiter cannot detect it, and will not be activated. 
During normal operation the clip limiting is inaudible. The limiter can be turned on or off by using the 
relevant clip limit switch. Note that in Bridge mode the limiters of both channels should be in the same 
position, either on or off. 
Some manufacturers of loudspeaker controllers do not recommend the use of clip limiters in amplifiers, as 
they tend to upset the tracking of the controller’s limiters. 
Apart from this single exception, Lab.gruppen

 

recommend to leave the clip limiters switched "on" (button 

depressed). As a side-effect, once the amplifier comes out of a protect condition, the output level has a 
slow rise time – the effect is like turning up the gain slowly. 

i~ÄKÖêìééÉå== =

=

=

=

=

========================

NR

 

rëÉê=j~åì~ä===Ñm=PQMM======sÉêëáçå=NKN========OMMPJNMJMO=

Содержание fP Series FP 3400

Страница 1: ...m PQMM rpbo j kr i...

Страница 2: ...5 3 5 Bridge mono mode features 8 5 4 Impedance matching MLS switch 8 5 4 1 A practical way to find your MLSTM settings 9 5 4 2 MLS technology the background 10 5 4 3 The problem 10 5 4 4 The solution...

Страница 3: ...ctric shock to humans The exclamation point within a triangle is intended to alert the user to presence of important operating and service instructions in the literature accompanying the product PKO t...

Страница 4: ...ardous voltages There are no serviceable parts inside and removal may void the warranty 18 An experienced user shall always supervise this professional audio equipment especially if inexperienced adul...

Страница 5: ...rred during shipping Be sure to save the carton and packing materials for the carrier s inspection It is also advisable to save the carton and packing material even if the amplifier is undamaged Shoul...

Страница 6: ...foam filters should always be used 7 Power switch Turns mains power on or off See page 11 and 14 QKP o m Figure 2 Rear panel 1 Output Speaker connector The Speakon connector from Neutrik may be unfami...

Страница 7: ...very often a so called loudspeaker processor or controller involved it being unique for the loudspeaker system In most cases the manufacturers of these processors and or loudspeakers recommend a spec...

Страница 8: ...polarity reversed on the input but polarity compensated by feeding the minus pin on the Channel B output with the output voltage Channel A output is connected in normal polarity mode By having channel...

Страница 9: ...shares the other 4 ohms part The power into 4 ohms from an fP 3400 MLS at 0dB is 1500W So the total bridged power into the 8 ohms load will be 2 x 1500 3000W ne RKQ f Ejip F The MLSTM switches are lo...

Страница 10: ...output power by changing MLS to a matching lower value 2dB or 4dB or 5dB 4 Try the setup with a musical signal If the amp runs into thermal protection or into current limiting audible as distortion or...

Страница 11: ...justed for a much higher current so it cannot interfere with the requirements by the loudspeaker impedance curve S fkpq ii qflk SKN j The amplifier is two rack units high 2U and will fit into a standa...

Страница 12: ...g via a resistor to chassis and the grounding system is automatic If a potential above 0 6V is presents in between signal ground and chassis ground a short circuit is introduced between the two thereb...

Страница 13: ...MAINS INPUT POWER MAX OUTPUT POWER Table 3 SKSKN The heat power can be calculated as in the following example We consider a headroom of at least 5dB 1 3 of full power and a 4 ohms load on an amplifier...

Страница 14: ...ss in long cables To daisy chain amplifiers use the XLR male connector provided on each channel labeled Link They are connected in parallel with the Neutrik Combojack on each input TKNKO r To connect...

Страница 15: ...r of the amplifiers in two ways by increasing the load impedance and by introducing resistive power losses WARNING To prevent from electrical shock do not operate the amplifier with any portion of the...

Страница 16: ...tures are inaudible All protection circuits work independent from each other VKNKN The clip limiter is included to prevent from dangerous clipped signals reaching the speaker and damaging it If an amp...

Страница 17: ...Q p All Lab gruppen amplifiers are completely short circuit protected The protection circuitry permits very high peak currents but still holds the output devices within the safe operation levels If a...

Страница 18: ...ve possible high frequency oscillations from the relevant input Fault The amplifier goes into thermal protection when running at low levels Check that nothing causes a short circuit at the amplifier s...

Страница 19: ...NN pmb fcf qflkp i K NU r j m PQMM s NKN OMMPJNMJMO...

Страница 20: ...ibility for any loss due to cancellation of any events or rent of replacement equipment or costs due to third party s or customer s loss of profit or any other indirect cost or losses however incurred...