Second,

 the maximum expected average current under worst case program material, which is 1/3 of full 

power according to the FTC standard. At this level the music will be in the state of constant clip and is 
therefore the highest power level one can obtain without completely obliterating the program. 

Last

, the "regular operating power" as defined by the safety standard IEC 65/ANSI/UL 6500 and used 

by a majority of safety agencies. The regular operating power is measured by using pink noise, and with 
an average output power equal to 1/8 of full power. The one eighth of the total power is as loud as you 
can play music while making some attempt to avoid obvious clipping. It also corresponds to a headroom 
of 9dB, which is very low for regular audio program.  

Power

1/3 Power

1/8 Power

Idle

[W]

note 1

note 2

fP 3400

8 ohms

2x

1100

1060

530

115

4 ohms

2x

1500

1440

685

115

2 ohms

2x

1700

1720

845

115

note 1

Average power with music as program source. The amplifier driven to clip level.

note 2

Normal music power with 9dB headroom, IEC standard power rating.

MAINS INPUT POWER

MAX OUTPUT POWER

Table 3 

SKSKN= `~äÅìä~íáçå=

The

 heat power

 can be calculated as in the following example: 

We consider a headroom of at least 5dB (1/3 of full power) and a 4 ohms load on an amplifier 
producing 1500 watts per channel. The 1/3 power per channel is accordingly 1500 / 3 = 500 watts, and 
total output 2 x 500 = 1000 watts. 
The power consumption according to the chart above is then 1975 watts. This chart shows the active 
power consumption of the amplifier with different loads and power levels.  

 

The

 heat power produced

 is the difference between the power consumption and output power: 

1440 - 1000 = 440 watts per amplifier. 
The chart below shows the heat power produced in watts, in kcal per hour, and also in BTU per hour. 
 

1/3 Power(1)1/8 Power (2) 1/3 Power(1) 1/8 Power (2)1/3 Power(1)1/8 Power (2)

[W]

[W]

kcal / h

kcal / h

BTU / h

BTU / h

fP 3400

8 ohms

327

255

280

220

1120

870

4 ohms

440

310

380

270

1500

1060

2 ohms

587

420

500

360

2000

1430

note 1

Average power with music as program source. The amplifier driven to clip level.

note 2

Normal music power with 9dB headroom, IEC standard power rating.

HEAT POWER

 

The 

efficiency

 can also be calculated, it being the output-power divided by the input-power:  

1000 watts / 1440 watts= 69%. 
 
 
 
 

i~ÄKÖêìééÉå== =

=

=

=

=

========================

NO

 

rëÉê=j~åì~ä===Ñm=PQMM======sÉêëáçå=NKN========OMMPJNMJMO=

Содержание fP Series FP 3400

Страница 1: ...m PQMM rpbo j kr i...

Страница 2: ...5 3 5 Bridge mono mode features 8 5 4 Impedance matching MLS switch 8 5 4 1 A practical way to find your MLSTM settings 9 5 4 2 MLS technology the background 10 5 4 3 The problem 10 5 4 4 The solution...

Страница 3: ...ctric shock to humans The exclamation point within a triangle is intended to alert the user to presence of important operating and service instructions in the literature accompanying the product PKO t...

Страница 4: ...ardous voltages There are no serviceable parts inside and removal may void the warranty 18 An experienced user shall always supervise this professional audio equipment especially if inexperienced adul...

Страница 5: ...rred during shipping Be sure to save the carton and packing materials for the carrier s inspection It is also advisable to save the carton and packing material even if the amplifier is undamaged Shoul...

Страница 6: ...foam filters should always be used 7 Power switch Turns mains power on or off See page 11 and 14 QKP o m Figure 2 Rear panel 1 Output Speaker connector The Speakon connector from Neutrik may be unfami...

Страница 7: ...very often a so called loudspeaker processor or controller involved it being unique for the loudspeaker system In most cases the manufacturers of these processors and or loudspeakers recommend a spec...

Страница 8: ...polarity reversed on the input but polarity compensated by feeding the minus pin on the Channel B output with the output voltage Channel A output is connected in normal polarity mode By having channel...

Страница 9: ...shares the other 4 ohms part The power into 4 ohms from an fP 3400 MLS at 0dB is 1500W So the total bridged power into the 8 ohms load will be 2 x 1500 3000W ne RKQ f Ejip F The MLSTM switches are lo...

Страница 10: ...output power by changing MLS to a matching lower value 2dB or 4dB or 5dB 4 Try the setup with a musical signal If the amp runs into thermal protection or into current limiting audible as distortion or...

Страница 11: ...justed for a much higher current so it cannot interfere with the requirements by the loudspeaker impedance curve S fkpq ii qflk SKN j The amplifier is two rack units high 2U and will fit into a standa...

Страница 12: ...g via a resistor to chassis and the grounding system is automatic If a potential above 0 6V is presents in between signal ground and chassis ground a short circuit is introduced between the two thereb...

Страница 13: ...MAINS INPUT POWER MAX OUTPUT POWER Table 3 SKSKN The heat power can be calculated as in the following example We consider a headroom of at least 5dB 1 3 of full power and a 4 ohms load on an amplifier...

Страница 14: ...ss in long cables To daisy chain amplifiers use the XLR male connector provided on each channel labeled Link They are connected in parallel with the Neutrik Combojack on each input TKNKO r To connect...

Страница 15: ...r of the amplifiers in two ways by increasing the load impedance and by introducing resistive power losses WARNING To prevent from electrical shock do not operate the amplifier with any portion of the...

Страница 16: ...tures are inaudible All protection circuits work independent from each other VKNKN The clip limiter is included to prevent from dangerous clipped signals reaching the speaker and damaging it If an amp...

Страница 17: ...Q p All Lab gruppen amplifiers are completely short circuit protected The protection circuitry permits very high peak currents but still holds the output devices within the safe operation levels If a...

Страница 18: ...ve possible high frequency oscillations from the relevant input Fault The amplifier goes into thermal protection when running at low levels Check that nothing causes a short circuit at the amplifier s...

Страница 19: ...NN pmb fcf qflkp i K NU r j m PQMM s NKN OMMPJNMJMO...

Страница 20: ...ibility for any loss due to cancellation of any events or rent of replacement equipment or costs due to third party s or customer s loss of profit or any other indirect cost or losses however incurred...

Отзывы: