DEVELOPING TEMPERATURE/TIME CHARTS

The Developing temperature/time charts below can be followed as a reference for adjusting the process time. The actual temperature process is the 

average between the temperature of solution before and during the process. Professional lid is especially useful for color negative C-41 process:

After about 2 minutes the developer has been poured in, you can check the temperature and calculate the avarage process temperature and adjust the 

developing time. For C-41 process we highly suggest a pre-soak with water (pre-heating tank and film) to reduce temperature drifting.

Contents - TEMPERATURE/TIME CHART 

|

Time/Temperature Chart for Color negative C-41 process

ILFORD Time/Temperature Chart for Black and White process

Time - Minutes

Tem
per

atur

e - °C

44
43
42

41

40

39
38
37
36
35
34
33
32

31

30
29
28

2

3

4

5

6

7

8

9

10

Time - Minutes

Tem

per

at

ur

e - °C

Example:   Developer temperature before to pour in the tank: 39°C.  Developer temperature after 2 minutes inside the tank: 35°C. 
 

The average is 37°C, so you can increase the developing time by 30 seconds according to the following c

hart.

Содержание PROFESSIONAL LID

Страница 1: ...USER MANUAL PROFESSIONAL LID by lab box it tutorials...

Страница 2: ...5mm and 120 films thanks to the two interchangeable modules and adjustable reels The films are loaded in full daylight and are wound onto the reel using the outer knob without the need to be in a dark...

Страница 3: ...3 INDEX User Manual Professional lid parts Parts Assembly Lid inserting Touchpad Recommendations Temperature Time Charts SafetyInformation Compliance 4 5 6 7 8 9 10 11 Index...

Страница 4: ...r and digital Thermometer It is a professional alternative to the standard Lab Box lid The Lid has a stainless steel probe that can measure the liquid temperature inside the tank during the process to...

Страница 5: ...and tighten the two screws To change the battery re open the slot by unscrewing the two screws AAA Battery PROBE The probe lock holds the temperature probe in the right position throughout the proces...

Страница 6: ...6 Contents LID INSERTING VIDEO 1 Insert the probe into the probe slot and close the lid by pushing it towards the tank like the standard lid HOW TO INSERT THE PROFESSIONAL LID...

Страница 7: ...timer or the pre sets Play Stop Touch to start or stop the timer 3 Time Pre sets Hold down 3 seconds to save the set time Touch to set quickly the saved time PVC 3m468 5315c black right cut line 7540C...

Страница 8: ...hed after about 1 minute Once the temperature stabilises the indication remains accurate within a range of 0 3 0 4 Once the chemicals are inside you cannot change the temperature You can only check th...

Страница 9: ...erature and adjust the developing time For C 41 process we highly suggest a pre soak with water pre heating tank and film to reduce temperature drifting Contents TEMPERATURE TIME CHART Time Temperatur...

Страница 10: ...e near any heat source or any type of equipment that generates heat including stereo amplifiers Do not use the device near flammable or explosive gases Do not use the device if you notice any unusual...

Страница 11: ...te radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interfe rence to radio communications However there is no guarantee that interference will...

Страница 12: ...www lab box it labboxfilmtank arsimago...

Отзывы: