background image

Trianco Newport

Page 7

**NOTE: A LOW FIRING RATE BAFFLE MUST BE INSTALLED PRIOR TO SHIPMENT.

  Dimensions

REF

NP 75

NP 85

NP 100

NP 110

NP 125

NP 135

NP 150

inches

mm

inches

mm

inches

mm

inches

mm

inches

mm

inches

mm

inches

mm

  Jacket Height

A

33

838

35½

902

35½

902

35½

902

41

1041

41

1041

41

1041

  Jacket Width

B

19¼

489

19¼

489

19¼

489

19¼

489

20½

521

20½

521

20½

521

  Jacket Length

C

20

508

20

508

20

508

20

508

21½

546

21½

546

21½

546

  Return Tapping Height

D

19½

495

19½

495

19½

495

19½

495

22

559

22

559

22

559

  Supply Tapping

E

31½

800

33½

851

33½

851

33½

851

638

965

38

965

38

965

  Coil Supply Height

F

25

635

27½

699

27½

699

27½

699

31½

800

31½

800

31½

800

  Smoke Outlet Diameter

G

6

152

6

152

6"

152

6

152

6

152

6

152

6

152

  Burner Center Line

H

216

216

8½"

216

216

10½

267

10½

267

10½

267

  Tankless Coil NPT

½

½

½

½

½

½

½

  Return NPT

  Supply NPT

  Specifications

  Firing Rate GPH

0.75

0.85

1.00

1.10

1.25

1.35

1.50

  Input MBTU/hr (kW)

85

25

103

30

120

35

133

39

150

44

160

47

177

52

  Output MBTU/hr (kW)

74

21

90

26

105

30

116

34

130

38

139

40

154

48

  Efficiency % AFUE

83.20

83.60

83.10

83.10

83.70

83.00

83

  Net Stack Temperature °F (°C)

375

191

312

156

353

178

371

188

351

177

386

197

417

214

  Shipping Weight - lbs. (kg)

285

129

310

141

310

141

310

141

368

167

368

167

368

167

  Water Content - gallons (L)

9.75

36.9

11.6

44

11.6

44

11.6

44

15.4

58

15.4

58

15.4

58.2

  Coil Size (GPM)

4

4

5

5

5

5

5

 Becket Burner Specifications

AFG BURNER PURCHASED TO BECKETT SPEC. #TRI-801 FOR NP UNITS

  Boiler Model

**NP 75

NP 85

NP 100

NP 110

NP 125

NP 135

NP 150

  Burner

AFG

AFG

AFG

AFG

AFG

AFG

AFG

  Nozzle

.75 x 70° A

.85 x 70° A

1.00 x 80° A

1.10 x 70° A

1.25 x 80° A

1.35 x 80° A

1.50 x 80° A

  Manufacturer

Delevan

Delevan

Delevan

Delevan

Delevan

Delevan

Delevan

  Static Plate

3 3/8

3 3/8

3 3/8

3 3/8

3 3/8

3 3/8

3 3/8

  Head Type

F3

F3

F3

F3

F6

F6

F6

  Pump Pressure

100

100

100

100

100

100

100

Содержание newport NP 100

Страница 1: ...gas in flue gases which could cause serious injury property damage or death Improper installation and or operation will void the warranty WARNING If the information in this manual is not followed exa...

Страница 2: ...n Air 3 1G Chimney and Draft Requirements 3 1H Jacket normally fitted 3 1I Oil Burner normally fitted 3 1J Boiler Controls normally fitted 3 1K Oil 3 1L Oil Storage and Pipe Layout 3 1M Electrical Wir...

Страница 3: ...insure an adequate supply of fresh air for combustion and ventilation an inlet and outlet opening should be provided at floor and ceiling level Each opening must have a minimum of one square inch 16 5...

Страница 4: ...water inlet 3 Connect pressure relief valve 11 if required by codes maximum 150 PSI as close to the unit as possible No other valves or restrictions may be installed between the DHW coil and the reli...

Страница 5: ...ping NPT Tankless Coil Tridicator Hydronic Return 1 Hydronic Supply 1 Aquastat Well Relief Valve Fitting Figure 2 Components Location PRESSURE RELIEF VALVE DRAIN PIPE IN ACCORDANCE WITH EXISTING REGUL...

Страница 6: ...ons may be removed by an acid treatment but your servicing company can advise on the most satisfactory method of cleaning or whether a replacement coil is necessary 1T Coil Removal 1 Switch off electr...

Страница 7: ...NPT 1 1 1 1 1 1 1 Specifications Firing Rate GPH 0 75 0 85 1 00 1 10 1 25 1 35 1 50 Input MBTU hr kW 85 25 103 30 120 35 133 39 150 44 160 47 177 52 Output MBTU hr kW 74 21 90 26 105 30 116 34 130 38...

Страница 8: ...ide 2 to front panel 3 with screws 2 Slide assembled jacket over boiler and secure side panels to base tray 3 Fix rear panel 4 to sides 4 Adjust corner brackets 5 on heat exchanger so they touch insid...

Страница 9: ...information PIPE LENGTHS H One Pipe Gravity System 3 8 O D 1 2 O D ft m ft m ft m 0 0 0 0 0 0 1 0 5 33 10 1 65 19 8 3 0 9 65 19 8 130 39 6 5 1 5 130 39 6 260 79 2 6 2 195 59 4 325 99 PIPE LENGTHS H Tw...

Страница 10: ...t means overload protection as required 24V Room Thermostat 1K L1 Hot Power Supply 120V L2 Circulator Switch Low Limit Circulator Hi Limit 1K2 Oil Burner Relay Heating Circulator AQUASTAT RELAY L8124A...

Страница 11: ...3 058 panel 2500 020 Burner Panel Assembly 125 155 before 1990 53 058 Burner Panel Assembly 125 155 after 1990 use with p n 53 0560 Part Number Description Size 53 090 Flue Cover Assembly 125 155 53 1...

Отзывы: