background image

Installation 

Table of Contents 

Pre-Installation Information ...................................................................................................................................................

...

.... 3

Storage Instructions ...................................................................................................................................................................... 

4

Packaging ...................................................................................................................................................................................... 

4

Transportation .............................................................................................................................................................................. 

5

Mounting Heater ........................................................................................................................................................................... 6 
Plumbing Installation .................................................................................................................................................................... 7 
Start Up ......................................................................................................................................................................................... 

9

DANGER 

Tip over hazard. System can crush you resulting in serious injury or death. Read and follow precautions in this installation 
manual that accompanied the heater for instructions on how to safely transport and mount. 

WARNING 

Read this manual BEFORE using this equipment. Failure to read and follow all safety and user information could result in 
death, serious personal injury, burns, property damage, or damage to the equipment. Keep this manual for future reference. 
Failure to comply with proper installation and maintenance instructions could 

contribute to the heater’s failure.

 

A qualified plumber or electrician should install and service this system. Install system according to these instructions and in 
compliance with national and local codes. 

For safe operation of the heater, observe all warning labels as indicated. 

Water heater system under pressure. DO NOT open enclosure while in operation. These heaters should never be used to 
provide 

“anti

-

scald”

 or 

“anti

-

chill”

 service. 

Hazardous voltage inside enclosure may result in serious burns or death. Disconnect power supply before performing any 
work in the enclosure. 

Failure to ground this system may result in death or serious injury. 

Make sure that all water supply lines have been flushed and then completely turned off before beginning installation. Debris 
in supply lines can cause valves to malfunction. 

CAUTION 

Hot pipes! DO NOT touch. May cause burns. 

NOTICE 

These heaters DO NOT provide protection from supply or outlet pipe freezing even when equipped with ENHT option(s).  

Consult local building and plumbing codes prior to installation. Should these codes differ from the information in the 
manual, follow the local codes. Inquire with governing authorities for additional local requirements.  

Regular checking and cleaning of t

he heater’s internal components and check stops is necessary for maximum life 

and proper 

product function. Periodic inspection and yearly maintenance by a licensed contractor is required. Corrosive water
conditions, and/or unauthorized adjustments or repairs could render the heater ineffective for its intended service. 
Frequency of cleaning and inspection depends upon local water conditions. For heaters with adjustable output 
temperatures, check and adjust as needed at initial installation and on a quarterly basis.  

IMPORTANT 

Read this entire installation manual to ensure proper installation. When finished with the installation, file this manual with 
the owner or maintenance department. Compliance and conformity to local codes and ordinances is the responsibility of the 
installer. Product warranties may be found under "Resources" on our website at 
www.laars.com. 

Separate parts from packaging and make sure all parts are accounted for before discarding any packaging material. If any 
parts are missing, do not begin installation until you obtain the missing parts. 

2

Содержание N Series

Страница 1: ...s Tankless Heater Models LCTEC216 2x LCTEN108 LCTEC252 2x LCTEN126 LCTEC288 2x LCTEN144 Voltage options for models 600V Three Phase 480V Three Phase 415V Three Phase 400V Three Phase 380V Three Phase...

Страница 2: ...shed and then completely turned off before beginning installation Debris in supply lines can cause valves to malfunction CAUTION Hot pipes DO NOT touch May cause burns NOTICE These heaters DO NOT prov...

Страница 3: ...Specific Requirements The N Series Skid C Series can be used in many different applications that require custom tuning for specific applications to maximize performance of the heater For use in a re c...

Страница 4: ...freeze protected from the factory and on site installation of freeze protection is the sites responsibility NOTICE For heaters with ENHT freeze protection option s If the heater is stored where the t...

Страница 5: ...pment intended to be used to transport the system Remove the shipping crate top and sides Locate the forklift tubes on the skid system and lift for transport NOTICE During transit transport close to t...

Страница 6: ...for service and maintenance of the cabinet enclosure and a minimum of 48 1219mm above the top of the cabinet enclosure is needed Verify skid system is in final installation location Secure the base to...

Страница 7: ...ate or Ball Type Valves Elbows nipples and fittings as needed Components included in the N Series Skid C Series Systems are different from the standard N Series Heater See dimensional drawings for ref...

Страница 8: ...Installation 8 68 1734 69 1759 80 2035 81 2065 80 2035 81 2065 N Series Skid C Series Dimensions 3 Plumbing Installation Cont...

Страница 9: ...ly following the union No valve or restriction is between the relief valve and the system or the relief valve and drain Shutoff valve is installed after pressure and temperature relief valve on outlet...

Страница 10: ...aars com Technical Support Website Email 603 335 6300 or Toll Free 800 900 9276 www laars com For field service please contact your professional installer or local Laars sales representative United St...

Отзывы: