background image

Page 21

36

 

Baffle, Heat Exchanger {8-T

ube}

 

10534601

 

10534602

 

10534603

 

10534604

 

10534605

 

10534606

 

10534607

 

 

 

 

 

(7)

 

(14)

 

(14)

 

(14)

 

(14)

 

(28)

 

(28)

 

 

 

Baffle, Heat Exchanger {10-T

ube}

 

 

 

 

 

 

 

 

10667708

 

10667709

 

 

 

 

 

 

 

 

 

 

(28)

 

(14)

 

Baffle, Heat Exchanger {10-T

ube}

 

 

 

 

 

 

 

 

 

10667702

 

 

 

 

 

 

 

 

 

 

 

 

(1

4)

37

 

Inlet/Outlet Header

, Machined

 

10364500

 

10364500

 

10364500

 

10364500

 

10364500

 

10364500

 

10364500

 

10364500

 

10364500

 

{S0094300 Glassed Cast Iron}

 

Inlet/Outlet Header

, Machined

 

10364501

 

10364501

 

10364501

 

10364501

 

10364501

 

10364501

 

10364501

 

10364501

 

10364501

 

{S0064000 Bronze}

38

 

Flange, 2-1/2" NPT

 Machined

 

10391303

 

10391303

 

10391303

 

10391303

 

10391303

 

10391303

 

10391303

 

10391303

 

10391303

 

{S0063600 Cast Iron}

 

Flange, 2-1/2" NPT

 Machined

 

10391304

 

10391304

 

10391304

 

10391304

 

10391304

 

10391304

 

10391304

 

10391304

 

10391304

 

{S0064400 Bronze}

39

 

Tee, Machined Flange

 

 

20130002

 

20130002

 

20130002

 

20130002

 

20130002

 

20130002

 

20130002

 

20130002

 

20130002

 

{Glassed Cast Iron}

 

Tee, Machined Flange {Bronze}

 

20150303

 

20150303

 

20150303

 

20150303

 

20150303

 

20150303

 

20150303

 

20150303

 

20150303

40

 

Baffle, W

ater Inlet

 

 

10338300

 

10338300

 

10338300

 

10338300

 

10338300

 

10338300

 

10338300

 

10338300

 

10338300

41

 

Barrier

, W

ater

 

 

20230101

 

20230101

 

20230101

 

20230101

 

20230101

 

20230101

 

20230101

 

20230101

 

20230101

 

 

 

(2)

 

(2)

 

(2)

 

(2)

 

(2)

 

(2)

 

(2)

 

(2)

 

(2)

42

 

Flange Gasket

 

 

S0063700

 

S0063700 

 

S0063700 

 

S0063700

 

S0063700

 

S0063700 

 

S0063700

 

S0063700

 

S0063700

 

 

 

(2)

 

(2)

 

(2)

 

(2)

 

(2)

 

(2)

 

(2)

 

(2)

 

(2)

43

 

Header Gasket w/Barrier

 

 

S0095100

 

S0095100

 

S0095100

 

S0095100

 

S0095100

 

S0095100

 

S0095100

 

S0095100

 

S0095100

 

 

 

(2)

 

(2)

 

(2)

 

(2)

 

(2)

 

(2)

 

(2)

 

(2)

 

(2)

44

 

W

ell, Immersion

 

 

E2074000

 

E2074000

 

E2074000

 

E2074000

 

E2074000

 

E2074000

 

E2074000

 

E2074000

 

E274000

45

 

W

ell, High Limit 

 

 

E0025900

 

E0025900

 

E0025900

 

E0025900

 

E0025900

 

E0025900

 

E0025900

 

E0025900

 

E0025900

46

 

Valve, Pressure Relief

 

   

A0063300

 

A0063300

 

A0063300

 

A0063600

 

A0063600

 

A0063600

 

A0063600

 

A0063600

 

A0063600

 

3/4 NPT

, 75 PSI

47

 

Temperature Gauge

 

 

A2089500

 

A2089500

 

A2089500

 

A2089500

 

A2089500

 

A2089500

 

A2089500

 

A2089500

 

A2089500

 

 

 

(2)

 

(2)

 

(2)

 

(2)

 

(2)

 

(2)

 

(2)

 

(2)

 

(2)

48

 

Flow Switch Kit {Indoor / Outdoor}

 

RE0013000

 

RE0013000

 

RE0013000

 

RE0013000

 

RE0013000

 

RE0013000

 

RE0013000

 

RE0013000

 

RE0013000

49

 

Pump, Motor

, Impeller

 

 

A2001800

 

A2001800

 

A2001800

 

A2001800

 

A2001800

 

A2001800

 

A2001800

 

A2001800

 

A2001900

50

 

Pump 

Adapter {Glassed Cast Iron}

 

10364200

 

10364200

 

10364200

 

10364200

 

10364200

 

10364200

 

10364200

 

10364200

 

10364200

 

Pump 

Adapter {Cast Bronze}

 

10364201

 

10364201

 

10364201

 

10364201

 

10364201

 

10364201

 

10364201

 

10364201

 

10364201

NOTE: Numbers in (

 ) represent quantity required for each size. Quantity is one otherwise.

Key

 

Description

 

 

Size

 

Size

 

Size

 

Size

 

Size

 

Size

 

Size

 

Size

 

Size

No

 

 

 

500

 

600

 

715

 

850

 

1010

 

1200

 

1430

 

1670

 

1825

MightyTherm Pool Heater

Содержание Mighty Therm AP

Страница 1: ...pas tenter d allumer d appareils Ne touchez aucun interrupteur Ne pas vous servir des t l phones dansle b timent o vous vous trouvez Appelez imm diatement votre fournisseur de gaz depuis un voisin Su...

Страница 2: ...or Pool Heaters 7 2 4 Gas Supply and Piping 7 2 5 Electrical Wiring 8 2 6 General Piping Instructions 9 2 7 Heater By Pass Piping 9 2 8 Temperature Sensor Placement and Installation 10 2 9 Automatic C...

Страница 3: ...N HEAT EXCHANGER C GLASS LINED COPPER N GLASS LINED CU NI A GLASS LINED COPR REVRSD M GLASS LINED CU NI REVRSD Option Code XX Standard JX CSD 1 HL High low gas pressure switches LC LWCO 100 lockout LW...

Страница 4: ...of ANSI standard Z223 1 and any local codes that may be applicable Inadequate combustion air supply may result in incomplete combustion sooting of the heat exchanger and unsafe operation of the heate...

Страница 5: ...and must not be connected to any portion of a mechanical draft system under positive pressure The flue outlet must be connected to a clear unobstructed vent of adequate capacity ending above the high...

Страница 6: ...ing system are located and the other spaces of the building Turn on any clothes dryer and any appliance not connected to the common venting system Turn on any exhaust fans including range hoods and ba...

Страница 7: ...or wall recess Avoid locations where wind deflection off structures might cause downdraft When such wind conditions are possible place the heater at least 3 feet 0 9m from the structures 3 Never insta...

Страница 8: ...cifically ordered otherwise 2 The 1825 models are supplied with 3 4 HP pump motors All other models are supplied with 1 2 HP pump motors Consult the National Electrical Code or the Canadian Electrical...

Страница 9: ...ilter system are made of plastic materials they may be damaged by the momentary back siphoning of hot water from the heater when the filter pump stops running The pressure relief valve installed in th...

Страница 10: ...Controls a Intermittent Ignition Pilots are automatically lit when the operating control calls for heat Systems 4 9 and 11 The unit performs its own safety check and opens the main valves only after...

Страница 11: ...e auto reset limit switch is provided as standard equipment on all heaters The temperature sensing bulb of the switch is field installed and should be located in the pool loop piping See Section 2 8 f...

Страница 12: ...auses air to be drawn into the heater and the secondary piping an automatic float type air vent should be permanently installed on top of the pump scroll 3 To check the heater firing proceed as follow...

Страница 13: ...pen throttle turn down outlet valve B slightly Observe the inlet thermometer for 5 minutes to see where the inlet temperature stabilizes If it remains under 110 F 43 C throttle outlet valve B a little...

Страница 14: ...caution is suggested for young children adjusted incrementally to obtain the desired pool operating temperature 7 An adjustable pump time delay relay is mounted in the control panel see Figure 11 Thi...

Страница 15: ...30 days 90 days and once every six months thereafter Fouling on the external surfaces of the heat exchanger is caused by incomplete combustion and is a sign of combustion air and or venting problems...

Страница 16: ...operating condition and preventing corrosion liming or other problems Proper pool water chemistry includes other values that must be maintained for swimmer safety Refer to your local agency having jur...

Страница 17: ...r u s s e r p m o r f y r a s s e c e n s a t s u j d a F Electric gas valve operator is F Disconnect wiring harness at gas valve terminals Check continuity of actuator burned out or shorted coil If o...

Страница 18: ...303 10548301 14 Tile Heat Shield Spacer Rear 10548401 10548402 10548403 10548404 15 Saddle Assembly End Tile 10533600 10533600 10533600 10533600 10533600 10533600 10533600 10533600 10533600 2 2 2 2 2...

Страница 19: ...Page 19 Figure 17 Parts Identification Mighty Therm Commercial Pool Heating Boiler Page 19 Figure 17 Parts Identi cation ONE PIECE PUMP VOLUTE MightyTherm Pool Heater...

Страница 20: ...n Combustible Base Rail 10539000 10539000 10539000 10539000 10539000 10539000 10539000 10539000 10539000 2 2 2 2 2 2 2 2 2 Water System 34 8 Tube Assembly Copper Tubes 10534701 10534702 10534703 10534...

Страница 21: ...101 2 2 2 2 2 2 2 2 2 42 Flange Gasket S0063700 S0063700 S0063700 S0063700 S0063700 S0063700 S0063700 S0063700 S0063700 2 2 2 2 2 2 2 2 2 43 Header Gasket w Barrier S0095100 S0095100 S0095100 S0095100...

Страница 22: ...00 58 Pilot Bracket Burner Weldment 10529502 10529502 10529502 10529502 10529502 10529502 10529502 10529502 10529502 59 Pilot Burner W0035800 W0035800 W0035800 W0035800 W0035800 W0035800 W0035800 W003...

Страница 23: ...Control Electronic E2305400 E2305400 E2305400 E2305400 E2305400 E2305400 E2305400 E2305400 E2305400 Single Try 72 Transformer 115V 24V R0021300 R0021300 R0021300 R0021300 R0021300 R0021300 R0021300 R0...

Страница 24: ...ssemblies When ordering tiles Assembly number is for all tiles Part numbers shown for the front of unit are the same for the rear tiles Check dimensions of old tile as shown here to confirm part numbe...

Страница 25: ...Page 25 Figure 19 Outdoor Parts 1 2 3 4 5 6 7 8 9 10 11 12 14 15 16 17 18 19 13 20 MightyTherm Pool Heater...

Страница 26: ...10665907 10665908 10665909 Copper Tube Cast Iron Tubs Outdoor 10 Tube Assembly 20001101 20001102 20001103 20001104 20001105 20001106 20001107 20001108 20001109 Copper Tube Bronze Tubs Outdoor 10 Tube...

Страница 27: ...Front End Panel 10657501 10657501 10657501 10657501 10657501 10657501 10657501 10657501 10657501 13 Right Front End Panel 10657502 10657502 10657502 10657502 10657502 10657502 10657502 10657502 10657...

Страница 28: ...905 636 0666 www Laars com Litho in U S A Laars Heating Systems 21 10 Document 3006V Laars Heating Systems Company reserves the right to change specifications components features or to discontinue pro...

Отзывы: