background image

Mini-Combo 

id

Page 9

 #

Qty Part #

Description

1

1

20085700

Weldment, Panel, Base

2

1

20085600

Weldment, Panel, Top

3

1

20086300

Weldment, Panel, Door

4

1

20086400

Panel, Side, Right

5

1

20127900

Weldment, Panel, Side, Left

6

1

20085900

Panel, Rear

7

1

20086500

Panel, Access

8

1

20084000

Bracket, Mounting, Left

9

4

20085400

Bracket, Support, Tank

10

2

P2019200 Cross, Black Iron, 1¼" NPT

11

4

P2014800 Fitting, Brass Compression,

7

/

8

" OD x ¾"

12

1

A2085600 Valve, Check, ¾" NPT

13 7.2ft P2015000 Tubing, Copper, Type “L”, 

7

/

8

" OD

14

1

A2085700 Valve, Drain, Tank, ¾" NPT

15

1

E0205000 Temperature Control, Electronic

16

1

A2085400 Valve, Relief, Temp & Pressure

17

1

A2085301 30 Gal. Water Tank,

Double Wall HX

1

A2085300 30 Gal. Water Tank,

Single Wall HX

18

2

20087300

Door Latch Assembly

19

1

A0066500 Pump, Circulator

20

1

A2086600 Valve, Check, 1¼" NPT

21

1

A2087600 Handle, Door

22

2

A2086700 Flange, Pump, ¾" NPT

23

1

A2085900 Well, Immersion, ¾" NPT

24

1

A2000400 Gauge, Pressure/Temperature

25

1

A2000600 Gauge, Temperature

26

1

20084001

Bracket, Mounting, Right

27

1

E2103100 Sensor

Содержание MCH

Страница 1: ...lified installer service agency gas supplier or call the factory Installation and Operation Instructions Document 2101B Note This document is to be used in conjunction with Document 1080 Installation...

Страница 2: ...2 LAARS HEATING SYSTEMS TABLE OF CONTENTS SECTION 1 General Information 1A Hazards and Your Safety Hot Water Can Scald 3 SECTION 2 Installation 3 2A Location 5 2B Heater Placement 5 2C Piping 5 2D Wir...

Страница 3: ...d elderly infirm or physically handicapped persons are more likely to be injured by hot water Never leave them unattended in a bathtub or shower Never allow small children to use a hot water tap or dr...

Страница 4: ...6 125 17 432 Boiler In Out NPT all sizes 1 Gas NPT all sizes Domestic Hot Water all sizes Inlet Outlet NPT Minimum clearances from combustible surfaces Left Side 2 51mm Right Side 2 51mm Rear 2 51mm F...

Страница 5: ...MC125 125 806 32 206 Area indicated is for one of two openings One at floor level and one at the ceiling so the total free area would be double the figures indicated Refer to Document 1080 for more i...

Страница 6: ...ATERIAL SUITABLE FOR 105 DEGREES C OR ITS EQUIVALENT HOT TANK AQUASTAT BR WALL THERMOSTAT FIELD SUPPLIED P 24V COM SEN NC NO COM TRANSFORMER BK 24V 115V R Y Y G W ZONE PUMP RELAY GROUNDING CONDUCTOR N...

Страница 7: ...s Supply Transformer Tank Stat common Domestic Demand N C Heating Demand N O Tank Pump energized High Limit Switch Inducer Energized Fan Proving Switch Heating Pump energized Flame Roll Out Safety Swi...

Страница 8: ...Page 8 LAARS HEATING SYSTEMS Figure 8 Parts Identification...

Страница 9: ...OD x 12 1 A2085600 Valve Check NPT 13 7 2ft P2015000 Tubing Copper Type L 7 8 OD 14 1 A2085700 Valve Drain Tank NPT 15 1 E0205000 Temperature Control Electronic 16 1 A2085400 Valve Relief Temp Pressur...

Страница 10: ...Page 10 LAARS HEATING SYSTEMS...

Страница 11: ...Mini Combo id Page 11...

Страница 12: ...CA 93021 805 529 2000 FAX 805 529 5934 20 Industrial Way Rochester NH 03867 603 335 6300 FAX 603 335 3355 480 S Service Road West Oakville Ontario Canada L6K 2H4 905 844 8233 FAX 905 844 2635 www laar...