background image

LAARS Heating Systems

Page 22

Figure 17. Hydronic Piping — Multi boilers for large homes with long / multiple radiant zones.

Installer to provide DHW

(anti-scald) thermostatic mixing valve.

Содержание Mascot II

Страница 1: ...monoxide gas in flue gases which could cause serious injury property damage or death Improper installation and or operation will void the warranty AVERTISSEMENT Assurez vous de bien suivres les instr...

Страница 2: ...ating System Pump Capacity 17 SECTION 6 Water Connections 6 1 Central Heat System Piping 17 6 2 Cold Water Make Up 17 6 3 Freeze Protection 18 6 4 Suggested Piping Schematics 19 6 5 Recognized Chemica...

Страница 3: ...Operating the Burner and Set Up 32 10 2 1 Burner Operation 32 10 2 2 Boiler Setup and Adjustment 33 10 3 Shutting Down Mascot II 33 10 4 To Restart Mascot II 33 SECTION 11 Maintenance 11 1 System Main...

Страница 4: ...he PRV should be installed prior to filling the system Refer to Figures 1 and 2 for PRV locations IMPORTANT The inlet gas pressure to the appliance must not exceed 13 W C 3 2kPa All installations must...

Страница 5: ...sponsible for shortages and damage to the shipment whether visible or concealed 1 5 Unpacking The Mascot II is shipped in a single crate with the following standard components packed with the applianc...

Страница 6: ...LAARS Heating Systems Page 6 Figure 2 Location of Components...

Страница 7: ...Water Heaters Page 7 Figure 3 Dimensional Drawing Cond Hydronic DHW 2nd Gas Hydronic DHW 2nd Outlet Return Inlet Return Supply Supply Outlet Supply 3 4 3 4 1 2 3 4 1 2 3 4 1 2 3 4 PVC copper NPT copp...

Страница 8: ...ertified to ULC S636 Intake air pipe must be PVC or CPVC that complies with ANSI ASTM D1785 F441 ABS that complies with ANSI ASTM D1527 or galvanized material Installer must comply fully with manufact...

Страница 9: ...ll bracket are purposely offset NOTE Mascot II models include 16 on center mounting holes on upper rear of boiler jacket These holes are not identified on the mounting template If mounting conditions...

Страница 10: ...of the combustion air intake pipe Maximum linear pipe length allowed is shown in Table 2 Subtract 5 allowable linear ft 1 5m for every elbow used The connection for the intake air pipe is at the top...

Страница 11: ...el or otherwise must be certified to this ULC standard Appropriate selection of vent material is very important for proper performance and safe operation of the Mascot II The flue temperature of the M...

Страница 12: ...e a nuisance or hazard 3 Locate the vent terminal so that vent gases cannot be drawn into air conditioning system inlets 4 Locate the vent terminal so that vent gases cannot enter the building through...

Страница 13: ...4 3 feet 91 cm J Clearance to nonmechanical air supply Direct vent only 12 30cm 80 285 36 91cm inlet to building or the combustion air inlet 399 850 Other than Direct vent 4 ft 1 2m below 36 inches 91...

Страница 14: ...shall be the responsibility of the property owner to secure the services of qualified licensed professionals for installation of hard wired carbon monoxide detec tors a In the event that the side wal...

Страница 15: ...um speed Do not operate a summer exhaust fan Close fireplace dampers 4 Place in operation the appliance being inspected Follow the lighting instructions Adjust thermostat so the appliance will operate...

Страница 16: ...ing plate Mascot II will function properly without the use of high altitude modification at elevations up to 10 000 feet 3050 m 2 The maximum inlet gas pressure must not exceed 13 W C 3 2kPa The minim...

Страница 17: ...toff valves where required by code Suggested piping diagrams are shown in Figures 12 through 19 These diagrams are meant only as a guide Components required by local codes must be properly installed M...

Страница 18: ...a boiler is subjected to freezing conditions and the boiler is not able to fire and or the water is not able to circulate there is a risk of freezing in the boiler or in the pipes in the system When w...

Страница 19: ...itable for use in the Mascot II Please refer to the manufacturers instructions for proper selection and application 1 Sentinel Performance Solutions Group 2 Hercules Chemical Company 3 Dow Chemical Co...

Страница 20: ...3 42 38 15 33 31 28 Table 8 DHW and Pump Performance Data Caution Scalding Risk Laars recommends the use of a thermostatic mixing valve at domestic hot water outlet boiler location to reduce potential...

Страница 21: ...Mascot II Boilers and Water Heaters Page 21 Figure 16 Hydronic Piping Multi boilers for large homes with long multiple baseboard zones Installer to provide DHW anti scald thermostatic mixing valve...

Страница 22: ...LAARS Heating Systems Page 22 Figure 17 Hydronic Piping Multi boilers for large homes with long multiple radiant zones Installer to provide DHW anti scald thermostatic mixing valve...

Страница 23: ...Mascot II Boilers and Water Heaters Page 23 Figure 18 Hydronic Piping Heating zones piped with zone pumps Installer to provide DHW anti scald thermostatic mixing valve...

Страница 24: ...LAARS Heating Systems Page 24 Figure 19 Hydronic Piping Heating zones piped with zone valves Installer to provide DHW anti scald thermostatic mixing valve...

Страница 25: ...he 24V field interlock as shown in the wiring diagram s 7 1 Main Power Plug power cord into a non switched 115V electrical outlet with 15A circuit protection FLA is 2A There is an internal 10A breaker...

Страница 26: ...teps until all Modbus port 1 terminal A connections are wired d Repeat the above steps for Modbus port 1 terminal B and C connections to complete the wiring e Connect the drain wire from the twisted p...

Страница 27: ...Mascot II Boilers and Water Heaters Page 27 Figure 22 Wiring Diagram...

Страница 28: ...in Tables 9 11 Once in a particular menu structure navigation consists of pressing the next button to scroll from item to item and then pressing the up and down arrows to change values Once the value...

Страница 29: ...to control temperature of an indirect tank 8 8 Lead Lag Cascading Lead Lag Cascading allows multiple boilers to be connected together and controlled from one common sensor input Up to 8 boilers can b...

Страница 30: ...Reset Outdoor reset varies the control point setpoint based on the actual outdoor temperature The reset function works as shown in Figure 24 When the outdoor air temperature reaches the high outdoor t...

Страница 31: ...then the boilers will simultaneously drop their firing rate If when reaching the point where both boilers drop toward their minimum firing rate 20 then the first slave will drop out Slave1 will remai...

Страница 32: ...energize for pre purge then the ignition sequence starts After all safety devices are verified the gas valve opens If ignition doesn t occur turn off the Mascot II check that there is SECTION 10 Oper...

Страница 33: ...can be forced to low fire to allow for easier setup Refer to Section 8 1 Table 11 for instructions on how to access the forced rate menu CO2 readings should be between the values shown in Table 13 If...

Страница 34: ...LAARS Heating Systems Page 34 GAS TYPE HIGH FIRE CO2 LOW FIRE CO2 Natural 9 0 9 0 Propane 10 0 10 0 Table 13 CO2 Range Figure 25 Adjustment Screws and Settings for CO2...

Страница 35: ...e Pump 11 2 1 Burner Check the burner for debris Remove the blower arm assembly to access the burner Remove the 4 bolts connecting the blower to the arm see Figure 32 Remove the 5 bolts which hold the...

Страница 36: ...e soot deposits with a wet brush or fine water spray before servicing the heat exchanger 1 Shut off the 120 Volt power supply to the boiler 2 Turn off all manual gas valves connecting the boiler to th...

Страница 37: ...um input CO2 Any high fire adjustment may affect low fire settings Screws for adjustment are shown in Figure 26 7 Reinstall front cover SECTION 12 Trouble Shooting 12 1 Sequence of Operation Mascot II...

Страница 38: ...92 Outlet sensor fault 93 DHW sensor fault Faulty sensor or wiring Check wiring replace sensor condition can be 95 Stack sensor fault caused by short 96 OAT temperature sensor fault Faulty outdoor ai...

Страница 39: ...values min 12 C 22 F to a difference greater than 22 F 12 C 255 CH setpoint minus ODR Increase Outdoor water min water temperature was temperature min and max too small min 12 C 22 F values to a diff...

Страница 40: ...ral Information To order or purchase parts for the LAARS Mascot II contact your nearest LAARS dealer or distributor If they cannot supply you with what you need contact Customer Service see back cover...

Страница 41: ...1 4 npt E2337500 8O Exchanger heat plate 8P Tie cable 14 3 4 long x 0 31 wide heat stabilized F2029100 8Q Flow switch water E2337400 8R Pipe tailpiece 1 npt M x 3 4 tube cu 12H4023 8S O ring 120 1 ID...

Страница 42: ...LAARS Heating Systems Page 42 Figure 28 Panel Assembly Door Top...

Страница 43: ...Mascot II Boilers and Water Heaters Page 43 Figure 29 Panel Assembly Door Middle...

Страница 44: ...LAARS Heating Systems Page 44 Figure 30 Panel Assembly Door Bottom...

Страница 45: ...Mascot II Boilers and Water Heaters Page 45 Figure 31 Base Jacket Assembly...

Страница 46: ...LAARS Heating Systems Page 46 Figure 32 Heat Exchanger Cabinet Fan...

Страница 47: ...Mascot II Boilers and Water Heaters Page 47 Figure 33 Heat Exchanger Burner Components...

Страница 48: ...LAARS Heating Systems Page 48 Figure 34 Pump Assembly Components...

Страница 49: ...Mascot II Boilers and Water Heaters Page 49 Figure 35 Plumbing Components...

Страница 50: ...LAARS Heating Systems Page 50...

Страница 51: ...Mascot II Boilers and Water Heaters Page 51...