5 – FIRST USE OR REUSE

Follow carefully the instructions before using the machine.

• open the external packing and take the machine out. Inspect the 

machine to ascertain that it is intact and in good condition. Check 

for the presence of all the accessories supplied with the machine 

(see paragraph 4)

• position the machine on a flat surface

• remove the cover and take out the water tank (

2

) (located inside 

the machine) and rinse it

• fill the container with clean water, return it to its housing and 

insert the silicon tubes. Close the cover on the machine.

The machines Giotto Evolution version (GEV) and Cellini Evolution 

(COV) offer the versatility of use with water tank (2) or with con-

nection to the water supply, using the appropriate pipe supplied 

(17). (SEE PAR. 5.1)

To use the machine with water tank (2) the switch (Z) has to be in 

position I (operation to be performed with the machine off).

WARNING! Before making the electric connection, 

make sure that the main power voltage corresponds 

to the specifications indicated on the data plate placed 

under the base of the machine.

Press the main power switch (

1

). Wait about 2 seconds to allow 

the circuit to perform a control check. The pilot light (

14

) will be 

switched on. To use the machine connected to the water network, 

position the switch (Z) on II (operation to be performed with the 

machine off).

Removing the cap (W) from the tray and connecting the silicon 

tube (

25

) to the pan (Y) you can download directly into the water 

drainage pipe. (see FIG.2)

The automatic level indicator will start filling the boiler with water

until it automatically reaches the prescribed level; the boiler water

level is automatically checked and the prescribed level will be

automatically refilled. 

Then wait until the machine reaches the 1.1 – 1.3 bar operating

pressure, by checking the boiler pressure on the pressure gauge 

(

5

).

The machine with a basin built-in is provided with a safety device

controlling the amount of water contained in the basin itself;

The green light (14) flashes to indicate the lack of water in the tank 

(2) and the device automatically cuts off all machine functions.

As it is filled up, the warning light switches off and the machine is 

ready again to deliver coffee.

Fill the filter holder (

12

) with the brewing group (

11

)

Thanks to the working of the lever group (

15

), brew some water to 

avoid the correct refilling of the coffee exchanger.

 

WARNING ! The coffee brewing and the power supply 

of the heating element don’t work when the water 

tank lamp (14) flashes.

During start-up: when the boiler pressure gauge (

5

) shows a 

pressure of approximately 0.5 bar, open slowly the steam tap 

handle (

7

), to discharge the air contained in the boiler, and wait 

until steam starts flowing out of the steam supply nozzle (

10

), then 

close it.

Wait for the reaching of the pressure and the correct thermic balan-

ce, after 10 minutes.

5.1 - WATER SYSTEM

Caution! The machine must be supplied with water having a 

hardness above 8°F degrees.

It is advisable to install a water softener for the machine water 

system. Ensure that you will be connecting the machine to drinka-

ble water mains.

The connection to the water supply of the machine must be in 

accordance with the country of destination.

The pressure of water entering the machine must not exceed 

0,65Mpa

- Connect the hose (17) to the connector (X) located under the 

machine and then connect it to the water mains.

- As far as the mains pressure is concerned, if this exceeds 0,5Mpa

(5bar), it is advisable to install a balanced pressure reducer for 

high pressure (a device whereby any mains increase does not 

affect the output pressure).

5.2  PRESSURE SWITCH REGULATION (Only Evolution and 

Premium Models)

The pressure switch shown in the picture has to keep the pressure

in the boiler constant, by activating or deactivating the electrical

heating element.

This pressure switch is adjusted during the final testing of the 

machine on a 1.1÷1.3 bar value; however, if the specific case 

requires a different operating pressure, the pressure switch ope-

rating range can be changed by operating on the regulation 

screw (U): by reducing the pressure, you will obtain a temperature 

reduction, by increasing the pressure, the water temperature also 

increases.

The regulation sense is shown in the picture and also on the pres-

sure switch itself. The pressure changes approximately 0.1 atm 

for each complete turn of the 

screw.

5.3 - PUMP PRESSURE 

SETTING (Only Evolution 

model)

Insert in the brewing unit the 

filter-holder filled with properly 

ground, dosed and pressed 

coffee. Activate the lever 

group endowment (15) and 

read the pressure on the pump 

manometer (4).

Note: The correct pressu-

re is 8/9 bar.

If the pressure displayed by the manometer should not prove cor-

rect, operate the pump pressure regulation screw (R - Fig.3), by 

turning it clockwise to increase pump pressure or anticlockwise to 

reduce pressure.

Once regulation is complete, check the pump setting by delivering

one or more coffee servings.

Fig. 1

Fig. 2

Содержание CELLINI CLASSIC

Страница 1: ...5 3 PUMP PRESSURE SETTING 6 COFFEE PREPARATION 23 7 CONTROL GROUPS 23 7 1 BREWING PRESSURE PROFILING CONTROL 23 8 HOT WATER DELIVERY 23 9 PREPARATION OF OTHER DRINKS 24 MILK CAPPUCCINO AND OTHER DRINK...

Страница 2: ...ecified in the data plate pla ed under the base of the machine is used in the country Put the machine in a safe place on a solid base away from heat sources and out of the reach of children Before con...

Страница 3: ...g type the cable does not hang from the table to avoid the risk of getting caught up in it 3 4 IMPORTANT SAFEGUARDS When using electrical appliances basic safety precautions should always be followed...

Страница 4: ...20 2 CHARACTERISTICS AND TECHNICAL DATA GIOTTO EVOLUTION GEV CELLINI EVOLUTION COV GIOTTO PREMIUM GIM CELLINI PREMIUM CEM CELLINI CLASSIC CCC...

Страница 5: ...r 22 One cup filter holder 23 Two cup filter holder 24 Closed filter 25 Silicone hose to drain water 26 Manometer BPPC Brewing Pressure Profiling Control MODEL GIOTTO EVOLUTION GEV GIOTTO PREMIUM GIM...

Страница 6: ...WARNING The coffee brewing and the power supply of the heating element don t work when the water tank lamp 14 flashes During start up when the boiler pressure gauge 5 shows a pressure of approximatel...

Страница 7: ...with their own filters and coffee grounds fitted into the unit throughout your days work so that the filter holder will always preserve an optimal temperature Caution When the machine is new the filt...

Страница 8: ...24 inside the filter holder 22 23 pour a spoonful of coffee machine detergent powder and fit the filter holder into the brewing unit to be cleaned Start the brewing unit using the unit con trol 15 an...

Страница 9: ...Improper grind 3 Too little coffee in filter 1 The machine had not reached the proper temperature 2 Filter holder not preheated 3 Cups not preheated 4 Pressure switch malfunction 1 Pressure switch ma...

Отзывы: