21
EOLO - COMFORT 80
EN
•
The plug must be easily accessible when the appliance is installed.
•
Please further assure you that your network is endowed with an efficient earth connection: if it does not exist
or if it is not efficient, please endow you with one in compliance with the law.
•
Connect the supply cable first on the back of the stove and then at a wall electric socket.
•
Do not use extension cables.
•
If the feeder cable is damaged, it must be replaced by an authorized technician.
•
When the stove is not going to be used for a long period of time, it advisable to remove the plug from the
socket on the wall.
11.9
CONNECTION TO THE EXTERNAL THERMOSTAT
The stove works through a thermostat probe placed in its inner. If you desire, the stove can be connected to an
external room thermostat. This operation must be executed by an authorized technician.
•
External thermostat: "SET TEMP ROOM" a temperature which is round 7°C.
•
External chronothermostat: "SET TEMP ROOM" a temperature which is round 7°C and desable the chrono
functions from the menu 03-01 "CHRONO ENABLE" ("OFF").
12
USE
12.1
INTRODUCTION
To have the best performance with the lowest consumption please follow the here descripted instructions.
•
The lightning of the pellets occurs very easily if the installation is correct and if the chimney flue is efficient.
•
Switch on the stove at Power 1 for at least 2 hours in order to enable the materials which make up the boiler
and the fireplace to adjust the inner springing stress.
•
Oily plant waste and lacquers can cause smells and smoke during the first working hours: it is advisable to
ventilate the room because they could be noxious to people and animals.
•
By using the stove the varnish inside the combustion chamber could be subjected to alterations. This
occurrence can be attributed to different reasons: an excessive stove overheating, the presence of chemical
agents in bad quality pellets, bad chimney draught, etc. Therefore varnish endurance in the combustion
chamber cannot be guarantee.
Set values from 1 to 5 are defined by the manufacturer and they can be changed only by
an authorized technician.
12.2
CONTROL PANEL
PANEL ELEMENT
DESCRIZIONE
P1 e P2: when you are in set temperature mode the thermostat values increase
or decrease from min. 6°C to max. 40°C. Keeping pressed P2 you check the fume
temperature at outlet. Both have programming functions.
P3: enables the access to temperature set and to User and Technician parameters
menu.
P4: ignition and shut down, unblocking from probable alarms and exit from programming.
P5 e P6: increase and decrease the calorific power from 1 to 5.
Crono: activated time schedule.