It is forbidden to connect any other appliance (wood stoves, cooker hoods, boilers, etc...).
•
The fume conduit must be placed at a distance of minimum 500 mm from flammable or heat-susceptible
components.
9.10
EXAMPLES OF CORRECT INSTALLATION
Fig. 8 - Example 1
LEGEND
1
Insulating material
2
Reduction from Ø100 to Ø80 mm
3
Inspection plug
4
Minimum safety distance = 0,5 mt
•
Chimney flue installation Ø100/120 mm with an enlarged drilling for pipe transit.
Fig. 9 - Example 2
LEGEND
1
Insulating material
2
Inspection plug
3
Chimney inspection entrance
4
Minimum safety distance = 0,5 mt
5
Inclination ≥ 3°
6
Level section ≤ 1 mt
•
Old chimney flue with an inserted pipe of minimum Ø100/120 mm and with an external door which enables
the chimney cleaning.