Display
Operating Procedure
Description
“Technical” Programming
Menu 93.2°C
Enter Password
0000
1
After entering the password and accessing the "Technician" programming menu, rotate the Encoder Knob until
the following is displayed.
Menu 93.2°C
Steam Boiler
Settings
2
Press the Encoder Knob to access the menu.
Menu 93.2°C
Steam Boiler
ENABLED
3
Press the Encoder Knob to access the menu, rotate the Encoder Knob to choose between
ENABLED and DISABLED,
press the Encoder Knob to confirm the option.
Menu 93.2°C
Steam Temperature
Current:124.4
Target:123.5
4
Press the Encoder Knob to access the menu, rotate the Encoder Knob to modify the value, press the Encoder
Knob to confirm the desired value.
Menu 93.2°C
Cup Warmer
Settings
• This parameter enables the technician
to set various parameters of the steam
boiler.
• The temperature of saturated water is
proportional to the pressure inside the
Steam Boiler. Therefore it is possible to
regulate the pressure of the steam boiler
by means of electronic temperature
control. Please use the following tables
as reference when setting the steam
boiler temperature.
• The maximum permitted value for the
temperature setting is 129°C.
• The parameter filling WITH PUMP allows
the technician to select the activation
of the water pump during the automatic
filling cycle of the service boiler.
• Only under unusual circumstances
would the option of “WITHOUT PUMP”
be chosen.
Steam Boiler
Menu 93.2°C
Coffee Boiler
Settings
Menu 93.2°C
Steam Boiler
Settings