EN
49
Display
Operating Procedure
Description
Steam Boiler
Temp 245.5
°
F
“Machine ON” Programming
• This parameter is set at the factory at a
preset nominal temperature.
• The temperature of saturated water
is proportional to the pressure inside
the Steam Boiler. Therefore it is
possible to regulate the pressure of the
steam boiler by means of electronic
temperature control. Please use the
following tables as reference when
setting the steam boiler temperature.
Steam Boiler Temperature
1
2
3
4
5
6
Enter into “Machine On” programming mode.
Press the button
to enter into programming mode
Then press the button
to access the adjustable parameters.
Scroll through the displayed parameters
using the button until the following display appears:
Press the button
or the button
to change tthe value of the flashing parameter.
When finished, press the button
to continue to the next parameter.
NOTE: It is also possible to change the temperature of the steam boiler using the “Quick Keys”. Please see the section
titled “Quick Keys”
200.5
o
F 06:30
La Marzocco T:00
Doses Setting
Select within30s
Clock Adjust
Steam Boiler
Temp 245.5
o
F
THE STEAM BOILER CONTAINS WATER AT ELEVATED
TEMPERATURES. WATER TEMPERATURE OVER 125 °F CAN CAUSE
SEVERE BURNS INSTANTLY OR DEATH FROM SCALDING.
Temperature
Pressure
247°F/119°C
1.0 bar
260°F/127°C
1.5 bar
272°F/133°C
2.0 bar
The saturation temperature of water will vary
will ambient atmospheric pressure.
Tables in this manual are created for
atmospheric pressure at sea level. Slight
adjustment in temperature will be required for
elevations other than sea level.
CAUTION
DANGER
Содержание GS/3
Страница 30: ......