All  La  Marche  Manufacturing  Co.  equipment  has  been  thoroughly  tested  and  found  to  be  in  proper  operating 
condition upon shipment from the factory and is warranted to be free from any defect in workmanship and material 
that may develop within three (3) years from date of purchase. 
 
Any part or parts of the equipment (except fuses, d.c. connectors and other wear-related items) that prove defective 
within a three (3) year period shall be replaced without charge providing such defect, in our opinion, is due to faulty 
material or workmanship and not caused by tampering, abuse, misapplication or improper installation. 
 
Should  a  piece  of  equipment  require  repair  during  the  warranty  period,  the  equipment  can  be  returned  to  the  La 
Marche factory to have the inspection, parts replacements and testing performed by factory personnel.  Should it be 
necessary to return  a piece of equipment or parts to the factory, the  customer or sales representative  must obtain 
authorization  from  the  factory.    If  upon  inspection  at  the  factory,  the  defect  was  due  to  faulty  material  or 
workmanship, all repairs will be made at no cost to the customer during the first three years.  Transportation charges 
or duties shall be borne by purchaser. 
 
In accepting delivery of the  equipment, the  purchaser assumes full responsibility for proper installation, installation 
adjustments  and  service  arrangements.    Should  minor  adjustments  be  required,  the  local  La  Marche  sales 
representative should be contacted to provide this service only. 
 
All  sales  are  final.    Only  standard  LaMarche  units  will  be  considered  for  return.    A  25%  restocking  fee  is  charged 
when return is factory authorized.  Special units are not returnable. 
 
In  no  event  shall  La  Marche  Manufacturing  Co.  have  any  liability  for  consequential  damages,  or  loss,  damage  or 
expense directly or indirectly arising from the use of the products, or any inability to use them either separately or in 
combination with other equipment or materials, or from any other cause.  In addition, any alterations of equipment 
made by anyone other than La Marche Manufacturing Co. renders this warranty null and void. 
 
La Marche Manufacturing Co. reserves the right to make revisions in current production of equipment, and assumes 
no obligation to incorporate these revisions in earlier models. 

 

The failure of La Marche Manufacturing Co. to object to provisions contained in customers' purchase orders or other 
communications shall not be deemed a waiver of the terms or conditions hereof, nor acceptance of such provisions. 
 
The above warranty is exclusive, supersedes and is in lieu of all other warranties, expressed or implied, including any 
implied  warranty of  merchantability or  fitness.   No person, agent or  dealer is authorized  to  give any warranties on 
behalf  of  the  Manufacturer,  nor  to  assume  for  the  Manufacturer  any  other  liability  in  connection  with  any  of  its 
products unless made in writing and signed by an official of the manufacturer. 

 

Содержание A75D

Страница 1: ...Digital METERS THREE PHASE ECN DATE CPN124997 20535 8 14 20098 8 13 20084 8 13 19784 12 12 106 BRADROCK DRIVE DES PLAINES IL 60018 1967 847 299 1188 FAX 847 299 3061 ISSUE DATE ECN 19609 7 12 INSTRUCT...

Страница 2: ...UTMOST IMPORTANCE THAT EACH TIME BEFORE USING THIS UNIT YOU READ THIS MANUAL AND FOLLOW THE INSTRUCTIONS EXACTLY To reduce risk of battery explosion follow these instructions and those published by t...

Страница 3: ...Gases from the battery will corrode and damage equipment A sealed maintenance free or valve regulated lead acid VRLA may be placed below this equipment Never allow the battery electrolyte to drip on t...

Страница 4: ...provide a copy of the claim to La Marche Mfg may void warranty service for any physical damages reported for repair HANDLING WARNING Equipment can be very heavy and top heavy Use adequate manpower or...

Страница 5: ...f the battery cables charger output and relay rack terminals Connect the proper battery cable to the ground bar or battery charger output terminal Energize the power supply by turning on the units AC...

Страница 6: ...75D A75DE series battery chargers provide separate voltage adjustments for floating or equalizing lead or nickel cadmium cells The float or equalize mode of operation is selected by pressing the equal...

Страница 7: ...E PHASE VOLTAGE MODEL NUMBER D B C A75D A75DE 208 240 480 50 24V 30 26 13 75 24V 44 38 19 100 24V 59 51 26 125 24V 74 64 32 150 24V 89 77 38 200 24V 118 102 51 50 48V 15 13 6 75 48V 22 19 10 100 48V 3...

Страница 8: ...E terminals of all chargers can be connected together to ensure all chargers automatically switch into and out of equalize mode together PROTECTION Current Walk In The output current gradually increas...

Страница 9: ...terminals together If the charger is equipped with a Remote Equalize Terminal connect the RE terminals together CURRENT WALK IN Output current will gradually increase after the battery charger is tur...

Страница 10: ...INFORMATION MINIMUM WIRE SIZES See Wire Size Chart lists the ac input and dc output minimum wire size requirements At distances exceeding 10 feet the dc wire size should be chosen to keep the voltage...

Страница 11: ...500000 3 52620 400 400000 1750 1750000 2 66360 500 500000 2000 2000000 DENOTES ALL SIZES LARGER THAN 0000 ARE EXPRESSED IN MCM TABLE OF CONVENTIONS CMA Cross section of wire in circular MIL area A Ult...

Страница 12: ...le lists the AC input and the DC output minimum wire size requirements At distances exceeding 10 feet the DC wire size should be chosen to keep the voltage difference between the units DC output termi...

Страница 13: ...done in the following order single power supply 1 Connect AC input line to the terminal block provided Be sure the AC circuit breaker is off 2 Observe the polarity of the battery cables and the rectif...

Страница 14: ...changing the rectifier current limit between 50 110 of rated output Turning the adjustment which is located on the unit front panel clockwise lowers the current limit turning counterclockwise raises...

Страница 15: ...lashing LED Solid LED High DC voltage 2 45 Vpc Lead Acid High DC voltage shutdown HVSD 2 5 Vpc Lead Acid Low DC current 5 A Timer mode Mode 0 Equalize Time 8 Hours OPT 46R RELAY PACKAGE 2 SETS OF FORM...

Страница 16: ...indicate The timer will automatically return the charger to the float mode when the equalize cycle is complete MODE 1 DISPLAY indicates P01 This mode of operation automatically starts an equalize cycl...

Страница 17: ...can be caused by defective batteries and customer loads make sure batteries and loads are free from defects NOTE If the problem is found to be located in the printed circuit boards the board should be...

Страница 18: ...output Meter should not indicate If the meter reads full scale deflection this indicates an ac dc short During shipping an AC wire may rub against the DC lugs terminals etc and cause a short These pro...

Страница 19: ...nal components 4 Check front panel meters and alarms for accuracy 4th Year REPEAT ABOVE WITH THE ADDITION OF 1 Check relay contacts for pitting or corrosion 2 Check capacitors for leakage 7th Year REP...

Страница 20: ...r installation installation adjustments and service arrangements Should minor adjustments be required the local La Marche sales representative should be contacted to provide this service only All sale...

Отзывы: