(P/N)762.128 Rev B EN 05/10 • © copyright 2009-2010
Kaba Mas LLC
page 10
Standard method
The 8130 Entry Device comes with a backplate with keyhole slots for ease of mounting (Figure 10).
1. Locate, drill and tap holes to mount the Entry Device to the outside of the safe door using the installation template provided.
2. Install the two #8-32 shoulder screws (US) or the two M4-0.7 shoulder screws (Metric) on the front of the safe door to mount the
Entry Device to the door (Figure 11).
3. Feed the Entry Device cable through the spindle cable hole from the front of the safe door (Figure 12).
4. Position the keyhole slotted holes on the backplate of the Entry Device over the mounting screws and then slide the Entry Device
down onto the mounting screws.
5. Remove the adhesive strip from the back of the keypad and carefully align before adhering to the housing. Refer to lock installation
instructions which are available at www.kaba-mas.com.
8130 alternate method (tamper evident for vds approval)
The 8130 Entry Device comes with the mylar portion of the keypad unattached (Figure 13).
1. Locate, drill and tap holes to mount the Entry Device to the outside of the safe door using the
installation template provided.
2. Feed the Entry Device cable through the spindle/cable hole from the front of the safe door.
3. Install the two M4-0.7 Phillips screws through the front of the housing to mount the Entry Device to
the door (Figure 13).
WARNING:
8130 Before completing the next step, you should ensure that the jumper switches for
time delay/open window are set as desired.
4. Remove the adhesive strip from the back of the keypad and carefully align before adhering to
the housing.
In order to use either the Dead bolt or Spring bolt locks, with Entries 3000, 3710, 3715, and 8130 a
method of retracting the bolt will be required. Knob Assembly (p/n 2666) is recommended.
Figure 10
Figure 11
Figure 12
Figure 13
8130 ENTRY DEVICE