(P/N)762.128 Rev B EN 05/10 • © copyright 2009-2010
Kaba Mas LLC
page 8
SWING BOLT
1. Mount the dial plate (p/n 3752) centered on the through hole (Figure 6). Attach the dial plate with the
two mounting screws US 8-32 (US) or the M4-0.7 (metric).
2. Slide the bearing plate (p/n 2674) over cable and press onto the fasteners on the
Entry Device (Figure 7).
3. Feed the key pad cable through the spindle cable hole from the front of the safe door.
4. Insert the two springs (p/n 2893) and blocking pins (p/n 2894) into the holes located on the
back of the keypad (Figure 8).
5. Rotate the key pad approx. 30° counter-clockwise and place keypad bushings into
the large openings on the dial plate. Then turn the key pad clockwise until the
blocking pin clicks, and secures the Entry Device to the safe door.
WARNING:
Once installed, the Entry Device cannot be removed from the safe door without causing
physical damage to the Entry Device.
6. When installing the lock, ensure that the Entry Device cable is running through the
channel at the back of the lock. Refer to lock installation instructions which are
available at www.kaba-mas.com.
3750, 3750-K, 3750KE, & 3190 ENTRY DEVICE
3750, 3750-K
3190
Swing Bolt
Mounting Screws
Pins & Springs
Insert Springs & Pins
Figure 6
Figure 7
Figure 8