2
Installation
2.1
Top view of the electronics board
Number
Description
1
Connector for supply and valves:
7: (switched)
6: Valve1–, Valve2– (ground)
5: (switched)
4: (switched)
3: (switched)
2: +VDC, output
1: -VDC, output, ground for Valve0a- and Valve0b-
+, -: VDC (Supply)
2
USB interface to connect the device to a PC
3
Connector for LCD
4
LED for internal supply
2.2
Connection of the supply
For supplying the device only direct current (DC) in the range of 12-24VDC may be used. This
voltage is also used to supply the valves!
2.3
Connection of the valves
Commonly available DC-valves or -pumps may be connected to the according outputs. Only valves
or pumps with a nominal voltage of 12 - 24VDC (according to the supply voltage) are to be used!
2.4
Connection of a PC
The device may be connected to a PC via USB for configuration purposes. Therefore the
configuration program has to be installed on the according PC.
A cable of type "USB-Mini-B <-> USB-A" has to be used for this connection!
1
2
3
4
7
6
5
4
3
2
1
+
-