background image

WTC01 Instruction Manual 

 Press "

" to confirm, then the minute flashes, press" + "or" - "to adjust. 

 Press "

" to confirm, then the alarm hour flashes, and press" + "or" - "to adjust. 

 Press "

" to confirm, then the alarm minute flashes, and press" + "or" - "to adjust. 

 Press "

" to confirm, then °C /°F temperature unit flashes, press" + "or" - "to adjust. 

 Press "

" to confirm and exit the setting mode, or you can also save the setting and exit the setting 

mode without pressing the button for 30 seconds at any time. 

 If you need to add or subtract quickly during the setting process, you can press and hold "+" or "-" for 

more than 2 seconds for quick adjustment. 

Alarm function: 

 Press "

" to turn on or off the alarm function. 

 The alarm clock lasts for 1 minute. You can touch " " to enter the snooze function for 5 minutes, or 

press any other key to exit the alarm directly. 

Maximum and minimum values: 

  Press  "+" to  check  the maximum 

  minimum 

  return  to  normal  mode for  temperature,  humidity 

and CO2 concentration. 

 If you press and hold "+" for 2 seconds while viewing the max and min values, you can clear the max 

and min values and start recording again. 

 

The maximum and minimum records will be automatically cleared and re-recorded at 0:00 each day. 

Manual baseline calibration function: 

  In  normal mode,  press and  hold  "+" for 2  seconds to  enter manual baseline  calibration  preparation 

mode. At this time, you can press " " to confirm entry, or press" + "or do not press the button for 30 
seconds to exit manual baseline calibration preparation mode. 

 The operation time of manual baseline calibration mode is 20 minutes. During the operation, you can 

press "+" to exit in advance. 

Carbon dioxide concentration alarm: 

 Press "-" to turn on or off the alarm function. 

 Press and hold "-" for 2 seconds to enter the CO2 concentration alarm setting. The CO2 concentration 

value flashes, and press "+" or "-" to adjust. 

 Press "

" to confirm and exit the setting mode, or you can also save the setting and exit the setting 

mode without pressing the button for 30 seconds at any time. 

 
***About manual baseline calibration and automatic baseline calibration of CO2 concentration: 

 Due to transportation, vibration, aging and other reasons, the carbon dioxide sensor may cause the 

zero drift and the detection accuracy is reduced. In order to restore the accuracy of the sensor, manual 
baseline calibration can be adopted to correct the drift. During the baseline calibration process, dispose 
of the product in an environment with an outdoor atmospheric CO2 concentration level (about 400ppm) 
to ensure that the CO2 concentration in the environment is stable. 

 Due to transportation, vibration, aging and other reasons, the carbon dioxide sensor may cause zero 

drift and reduce the detection accuracy, so the sensor will correct the drift through the built-in automatic 
baseline  calibration  algorithm.  About  2days  after  sensor  start,  will  be  stored  within  2days  minimum 
carbon dioxide concentration values, to amend the basic value of the atmospheric environment outdoor 
carbon dioxide concentration(about 400ppm), since the time of about 7days, will be stored within 7days 
of  the  lowest  carbon  dioxide  concentration  values,  to  amend  the  basic  value  of  the  atmospheric 
environment  outdoor  carbon  dioxide  concentration  (about  400ppm).The  cycle  was  then  repeated  for 
7days.Please  ensure  that  the  CO2  concentration  is  reduced  to  the  outdoor  atmospheric  level(about 
400ppm) within about 2days after the sensor start and for each 7 days of continuous operation. 

 Automatic baseline calibration function is suitable for office, home and other non-all-weather personnel 

Отзывы: