5. Setting up 

 

Firstly, choose to use the adaptor (included in this set) or bat-
teries for operation.  Both these methods allow for operation of 
using wireless 433MHz transmission or cable connection be-
tween the base station and the sensors and setting up for both 
methods is as follows: 
 
 

Base Station: 

 

 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Setting up using batteries: 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Important: To avoid operating problems, please take note of bat-

tery polarity if inserting any batteries 

 
1) Pull away the rain cover of the thermo-hygro sensor to reveal the 

three sockets (for the wind sensor, rain sensor and the base sta-
tion) 

2) Connect the attached cables of wind and rain sensors to the 

corresponding sockets of the thermo-hygro sensor by clicking 
them into place 

3) Open the battery cover of the thermo-hygro sensor located below 

the three sockets and insert 2 x AA, IEC LR6, 1.5V batteries and 
close the cover 

4) Open the base station’s battery cover located at the back of the 

unit and insert 3 x AA, IEC LR6, 1.5V batteries into the battery 
compartment and close the battery cover 

Socket for 
Thermo-Hygro 
Sensor

 

 
PC COM 
Port 

 

 

 

Battery  
Compartment 

 

Battery Cover 

 

Thermo-Hygro Sensor 

 

Sensor sockets 

 

Sensor sockets 

 

Содержание WS2307

Страница 1: ...Features of the base station Features of the thermo hygro sensor Features of the wind sensor Features of the rain sensor 3 Safety Notes 4 Packaged contents 5 Setting up 6 Operation using cable connec...

Страница 2: ...ther station is designed to work easily with your PC There are tedious requirements to turn your PC ON or OFF simply connect and disconnect the PC cable at any time System Requirements for PC use The...

Страница 3: ...liable For reasons of safety and operation alterations to this device are strictly prohibited To operate the weather station use only supplied adaptor and batter ies of the recommended type Do not le...

Страница 4: ...of the thermo hygro sensor to reveal the three sockets for the wind sensor rain sensor and the base sta tion 2 Connect the attached cables of wind and rain sensors to the corresponding sockets of the...

Страница 5: ...and will result in higher power consumption Therefore batteries will have a shorter life span for cable connection compared to using 433MHz To operate using cable connection simply use the enclosed 1...

Страница 6: ...door temperature and humidity 2 Outdoor temperature and humidity 3 Outdoor wind chill 4 Dew point 5 Rainfall 24 hour 6 Rainfall 1hour 7 Rainfall Total 8 Relative and absolute pressure 9 Wind speed win...

Страница 7: ...ndered from all directions ideal mast size should be from 16mm 33mm Once the wind sensor is fixed onto the mast connect the cable to the corresponding thermo hygro sensor socket so that operating powe...

Страница 8: ...C use please see PC user manual in the enclosed Heavy Weather CD ROM However if you wish to make a full reset of the base station and return to the original factory settings simultaneously press and h...

Страница 9: ...ion will register this as a change in weather Air Pressure LCD Section 1 The air pressure reading is displayed here Press the PRESSURE key to toggle between relative and absolute air pressure displays...

Страница 10: ...ection will be displayed on the LCD compass on the wind section Press the WIND key to toggle between wind direc tion as numerical e g 225 and abbreviated characters e g SW as well as numerical wind sp...

Страница 11: ...nual setting mode allows the user to change several basic settings which is done by accessing one mode after the other simply by pressing the SET key After the final mode or if no key is pressed for 3...

Страница 12: ...or min with time and date Rainfall 24 hours max or min with time and date Rainfall 1 hour max or min with time and date Rainfall total max only with time and date When in any of the above modes press...

Страница 13: ...oggle to the indoor temperature low alarm set mode 5 Press and hold the SET key to enter the indoor temperature low setting values temperature digits will start flashing and set the desired indoor tem...

Страница 14: ...will start flashing and set the desired wind chill low by using the PLUS or MINUS keys 6 Press ALARM key to confirm and press the MIN MAX key to re turn the normal display mode or press the ALARM onc...

Страница 15: ...rm 2 Continue to press the ALARM key until you reach the wind direc tion alarm set mode 3 Press and hold the SET key to enter the wind direction setting values 4 Using the PLUS or MINUS keys select th...

Страница 16: ...Tempera ture 30 0 C 69 9 C Indoor Temperature 9 9 C No alarm will sound if the minimum indoor temperature alarm is set below 9 9 C 59 9 C Humidity all 20 RH 95 RH Rainfall 24h 0 0 mm 1000 mm Rainfall...

Страница 17: ...y in the thermo hygro sensor 1 Open the battery cover 2 Remove the old batteries and insert with new ones of the rec ommended type and replace the cover Once the sensor is powered up press and hold th...

Страница 18: ...ese devices allow the change to an interference free frequency Such measures will effectively overcome interferences 20 Transmission Range The transmission distance from the thermo hygro sensor to the...

Страница 19: ...seconds Indoor data Pressure temperature 4 times per minute Indoor Temperature Range 9 9 C to 59 9 C shows OFL if outside range Resolution 0 1 C Measuring Range Rel Humidity 20 to 95 if the relative...

Страница 20: ...n of Conformity We hereby declare that this wireless transmission device does comply with the essential requirements of R TTE Directive 1999 5 EC EJIN23000012 For use in Germany Austria UK France Belg...

Отзывы: