Features of the Thermo-Hygro Sensor 
The thermo-hygro sensor measures the outdoor temperature and 
relative humidity.  It also collects the readings from the rain and wind 
sensors before transmitting the data to the base station by wireless 
433MHz or by the 10 meter cable included in this set. 

 

Features of Wind sensor 
The wind sensor measures wind speed and wind direction and sends  
the data to thermo-hygro sensor which in turn transmits the data to 
the base station.  Operating power is taken from the thermo-hygro 
sensor using a 10 meter cable connection. 

 

Features of Rain sensor 
The rain sensor measures the rainfall and sends the data to thermo-
hygro sensor which in turn transmits the data to the base station.  
Operating power is taken from the thermo-hygro sensor by a 10 meter 
cable connection. 

 

3. Safety Notes 

 

• 

Damage caused by failure to comply with this instruction manual will 
invalidate any guarantee! The manufacturer and supplier will not be 
held liable for actions due to failure to comply with this instruction 
manual or from data inaccuracies that may occur with this product! 

 

• 

In case of harm or damage to a person or property caused by im-
proper handling or failure to comply with this instruction manual, the 
manufacturer and supplier cannot be held liable.   

 

• 

For reasons of safety and operation, alterations to this device are 
strictly prohibited. 

 

• 

To operate the weather station, use only supplied adaptor and batter-
ies of the recommended type. 

 

• 

Do not leave used-up batteries in the device as these may corrode 
and release chemicals that may damage the unit. 

 

• 

Inserting batteries in an incorrect polarity will cause damage to this 
product. 

 

• 

This product is not a toy kept out of the reach of children. 

 

• 

Do not depose new or used batteries to fire as they may explosion or 
release dangerous chemicals. 

 

• 

This product is not to be used for medical purposes or for public 
information. 

 

4. Packaged Contents 
 
Before setting up, carefully unpack the contents onto a table or flat 
surface and check that the following are complete: 

 

Item: 

Consisting of: 

Fittings: 

Illustration: 

 

 

 

 

Base 
Station 

• 

Main unit 

 
 
 
 
 

• 

AD/DC 230V power 
Adaptor - optional use 
(included) 

 
 
 
 
 
 

 

 

 

 

Thermo-
Hygro 
Sensor 

• 

Main unit 

• 

Rain protection 
cover 

 
 
 

• 

10 meter cable - 
optional connection to 
the base station (in-
cluded) 

• 

Wall mounting screws 

• 

Plastic anchors for 
screws 

 

 
 

 

 

 

 

Wind 
Sensor 

• 

Main unit with 
wind vane 

• 

10 meter cable 
(already at-
tached to the 
main unit) 

• 

Mast holder  

 

• 

2 x U-bolts for mast 
holder 

• 

4 x Washers 

• 

4 x Nuts 

• 

1 x screw (to fix main 
unit to the mast holder 

 
 
 
 
 
 

 

 

 

 

Rain 
Sensor 

• 

Main unit (base 
and funnel) 

• 

10 meter cable 
(already at-
tached to the 
main unit) 

 

 

 
 
 
 
 

 

 

 

 

Heavy 
weather 
PC 
soft-
ware 

CD-Rom format 
(English, Ger-
man and French 
languages only) 

• 

2 meter PC cable for 
PC connection - op-
tional use (included) 

 
 
 

 
 

 
 
 

 

 

 

 

Содержание WS2307

Страница 1: ...Features of the base station Features of the thermo hygro sensor Features of the wind sensor Features of the rain sensor 3 Safety Notes 4 Packaged contents 5 Setting up 6 Operation using cable connec...

Страница 2: ...ther station is designed to work easily with your PC There are tedious requirements to turn your PC ON or OFF simply connect and disconnect the PC cable at any time System Requirements for PC use The...

Страница 3: ...liable For reasons of safety and operation alterations to this device are strictly prohibited To operate the weather station use only supplied adaptor and batter ies of the recommended type Do not le...

Страница 4: ...of the thermo hygro sensor to reveal the three sockets for the wind sensor rain sensor and the base sta tion 2 Connect the attached cables of wind and rain sensors to the corresponding sockets of the...

Страница 5: ...and will result in higher power consumption Therefore batteries will have a shorter life span for cable connection compared to using 433MHz To operate using cable connection simply use the enclosed 1...

Страница 6: ...door temperature and humidity 2 Outdoor temperature and humidity 3 Outdoor wind chill 4 Dew point 5 Rainfall 24 hour 6 Rainfall 1hour 7 Rainfall Total 8 Relative and absolute pressure 9 Wind speed win...

Страница 7: ...ndered from all directions ideal mast size should be from 16mm 33mm Once the wind sensor is fixed onto the mast connect the cable to the corresponding thermo hygro sensor socket so that operating powe...

Страница 8: ...C use please see PC user manual in the enclosed Heavy Weather CD ROM However if you wish to make a full reset of the base station and return to the original factory settings simultaneously press and h...

Страница 9: ...ion will register this as a change in weather Air Pressure LCD Section 1 The air pressure reading is displayed here Press the PRESSURE key to toggle between relative and absolute air pressure displays...

Страница 10: ...ection will be displayed on the LCD compass on the wind section Press the WIND key to toggle between wind direc tion as numerical e g 225 and abbreviated characters e g SW as well as numerical wind sp...

Страница 11: ...nual setting mode allows the user to change several basic settings which is done by accessing one mode after the other simply by pressing the SET key After the final mode or if no key is pressed for 3...

Страница 12: ...or min with time and date Rainfall 24 hours max or min with time and date Rainfall 1 hour max or min with time and date Rainfall total max only with time and date When in any of the above modes press...

Страница 13: ...oggle to the indoor temperature low alarm set mode 5 Press and hold the SET key to enter the indoor temperature low setting values temperature digits will start flashing and set the desired indoor tem...

Страница 14: ...will start flashing and set the desired wind chill low by using the PLUS or MINUS keys 6 Press ALARM key to confirm and press the MIN MAX key to re turn the normal display mode or press the ALARM onc...

Страница 15: ...rm 2 Continue to press the ALARM key until you reach the wind direc tion alarm set mode 3 Press and hold the SET key to enter the wind direction setting values 4 Using the PLUS or MINUS keys select th...

Страница 16: ...Tempera ture 30 0 C 69 9 C Indoor Temperature 9 9 C No alarm will sound if the minimum indoor temperature alarm is set below 9 9 C 59 9 C Humidity all 20 RH 95 RH Rainfall 24h 0 0 mm 1000 mm Rainfall...

Страница 17: ...y in the thermo hygro sensor 1 Open the battery cover 2 Remove the old batteries and insert with new ones of the rec ommended type and replace the cover Once the sensor is powered up press and hold th...

Страница 18: ...ese devices allow the change to an interference free frequency Such measures will effectively overcome interferences 20 Transmission Range The transmission distance from the thermo hygro sensor to the...

Страница 19: ...seconds Indoor data Pressure temperature 4 times per minute Indoor Temperature Range 9 9 C to 59 9 C shows OFL if outside range Resolution 0 1 C Measuring Range Rel Humidity 20 to 95 if the relative...

Страница 20: ...n of Conformity We hereby declare that this wireless transmission device does comply with the essential requirements of R TTE Directive 1999 5 EC EJIN23000012 For use in Germany Austria UK France Belg...