background image

 

24

WARRANTY INFORMATION 

La Crosse Technology, Ltd provides a 1-year limited warranty on this product against 
manufacturing defects in materials and workmanship. 
 
This limited warranty begins on the original date of purchase, is valid only on products 
purchased and used in North America and only to the original purchaser of this product.  To 
receive warranty service, the purchaser must contact La Crosse Technology, Ltd for 
problem determination and service procedures.  Warranty service can only be performed 
by a La Crosse Technology, Ltd authorized service center.  The original dated bill of sale 
must be presented upon request as proof of purchase to La Crosse Technology, Ltd or La 
Crosse Technology, Ltd’s authorized service center. 
 
La Crosse Technology, Ltd will repair or replace this product, at our option and at no 
charge as stipulated herein, with new or reconditioned parts or products if found to be 
defective during the limited warranty period specified above.  All replaced parts and 
products become the property of La Crosse Technology, Ltd and must be returned to La 
Crosse Technology, Ltd.  Replacement parts and products assume the remaining original 
warranty, or ninety (90) days, whichever is longer.  La Crosse Technology, Ltd will pay all 
expenses for labor and materials for all repairs covered by this warranty.  If necessary 
repairs are not covered by this warranty, or if a product is examined which is not in need or 
repair, you will be charged for the repairs or examination.  The owner must pay any 
shipping charges incurred in getting your La Crosse Technology, Ltd product to a La 
Crosse Technology, Ltd authorized service center.  La Crosse Technology, Ltd will pay 
ground return shipping charges to the owner of the product to a USA address only. 
 
Your La Crosse Technology, Ltd warranty covers all defects in material and workmanship 
with the following specified exceptions: (1) damage caused by accident, unreasonable use 
or neglect (including the lack of reasonable and necessary maintenance); (2) damage 
occurring during shipment (claims must be presented to the carrier); (3) damage to, or 
deterioration of, any accessory or decorative surface; (4) damage resulting from failure to 
follow instructions contained in your owner’s manual; (5) damage resulting from the 
performance of repairs or alterations by someone other than an authorized La Crosse 
Technology, Ltd authorized service center; (6) units used for other than home use (7) 
applications and uses that this product was not intended or (8) the products inability to 
receive a signal due to any source of interference..  This warranty covers only actual 
defects within the product itself, and does not cover the cost of installation or removal from 
a fixed installation, normal set-up or adjustments, claims based on misrepresentation by the 
seller or performance variations resulting from installation-related circumstances. 
 
LA CROSSE TECHNOLOGY, LTD WILL NOT ASSUME LIABILITY FOR INCIDENTAL, 
CONSEQUENTIAL, PUNITIVE, OR OTHER SIMILAR DAMAGES ASSOCIATED WITH 
THE OPERATION OR MALFUNCTION OF THIS PRODUCT.  THIS PRODUCT IS NOT 
TO BE USED FOR MEDICAL PURPOSES OR FOR PUBLIC INFORMATION.  THIS 
PRODUCT IS NOT A TOY.  KEEP OUT OF CHILDREN’S REACH. 
 
This warranty gives you specific legal rights.  You may also have other rights specific to 
your State.  Some States do no allow the exclusion of consequential or incidental damages 
therefore the above exclusion of limitation may not apply to you. 
 
For warranty work, technical support, or information contact: 
 

La Crosse Technology 

2809 Losey Blvd. S. 

La Crosse, WI 54601 

Phone: 608.782.1610 

Fax: 608.796.1020 

 
 

Содержание WS-9115

Страница 1: ...WS 9115 Wireless 433 MHz Wireless Weather Station Instruction Manual...

Страница 2: ...the Time Date Manually 10 11 Temperature Measuring Units F C 11 Air Pressure Measuring Units inHg hPa 11 Relative Pressure Setting 11 12 Forecast Sensitivity Setting 12 Features and Operation Time Al...

Страница 3: ...ived up to 2 000 miles away through the internal antenna in the indoor weather station However due to the nature of the Earth s Ionosphere reception is very limited during daylight hours The indoor we...

Страница 4: ...place your remote thermo hygro sensor outdoors and set your time The remote thermo hygro sensor should be placed in a dry shaded area The remote thermo hygro sensor has a range of 80 feet Any walls th...

Страница 5: ...nsor 2 Remove the battery cover located on the backside of the sensor above the mounting post and bracket Press the arrow and slide the battery cover off 3 Observing the correct polarity install 2 Alk...

Страница 6: ...st locations the WWVB reception indicator looks like a tower icon will flash The indoor weather station requires five full minutes of good reception to successfully capture the signal and set to the c...

Страница 7: ...ing mode and your actual data shown will be different based on your local settings and conditions Radio controlled time WWVB Reception Indicator Moon Phase Display Date Display Indoor Temperature Humi...

Страница 8: ...ime Zone 3 DST ON OFF 4 Radio controlled Time ON OFF 5 12 24 hour time mode 6 Hour 7 Minute 8 Year 9 Month 10 Date 11 F C 12 inHg hPa 13 Relative pressure setting 14 Forecast sensitivity B LCD Contras...

Страница 9: ...the top of the display and a number will flash next to it 3 Press and release the SET button three more times to advance to the Radio controlled time ON OFF setting 4 RCC will appear to the right of...

Страница 10: ...to advance to the Manual Minutes setting 4 The minutes will begin to flash at the top of the display 5 Press and release the OUT button to select the desired minutes 6 Press and release the SET button...

Страница 11: ...unit 6 Press and release the SET button to confirm the temperature measuring unit and continue to the Air Pressure Measuring Units setting M Air Pressure Measuring Units Selection inHg hPa 1 Press and...

Страница 12: ...ther side of the forecast icon and a flashing number will appear under the forecast icon 5 Press and release the OUT button to select the desired forecast sensitivity setting Note Barometric air press...

Страница 13: ...to confirm the setting or wait for 20 seconds and the display will automatically return to the normal mode 2 To activate the alarm a Press and release the ALM DATE button to toggle between the alarm...

Страница 14: ...indoor temperature and humidity The minimum and maximum values are updated automatically when a new minimum or maximum is recorded or until manually reset a From the normal display mode press and rel...

Страница 15: ...r at least three seconds You will see then that the values will reset to the current temperature and humidity and corresponding time D Multiple Remote Temperature Sensors The WS 9115 is able to receiv...

Страница 16: ...remote sensor will have its own minimum and maximum values stored E Comfort Indicator for Indoor Temperature and Humidity 1 The comfort level indicator appears inbetween the indoor tempearture and hu...

Страница 17: ...en slow and gradual f The sensitivity of the change in foreacst icon is set by the user in section F of the Detailed Set Up Guide G Weather Tendency Arrows 1 Along with the forecast icon there is a pr...

Страница 18: ...4 The 0 on the vertical axis indicates the current air pressure value 5 The 0h on the horizontal axis indicates the current hour thus the current air pressure also 6 Each bar on the bar graph represen...

Страница 19: ...weather station loses the signal from the remote sensor it will display the last temperature reading for 15 minutes After 15 minutes of not receiving any signals the remote temperature will display A...

Страница 20: ...ounting post into the receptor of the mounting bracket B Mounting the WS 9115 Indoor Weather Station The indoor weather station can be mounted in two ways free standing or hanging on a wall To have th...

Страница 21: ...isplays and units with a soft damp cloth Do not use solvents or scouring agents they may mark the displays and casings C Do not submerge in water D Immediately remove all low powered batteries to avoi...

Страница 22: ...te sensors are in use check location with corresponding boxed numbers 3 Move away from sources of heat cold 4 Adjust relative air pressure to a value from a reliable source TV radio etc 5 The indoor w...

Страница 23: ...to 1040 hPa Relative inHg adjustable 28 35 inHg to 30 72 inHg Sensitivity setting hPa 2 hPa to 4 hPa Air pressure history For the past 24 hours 0 3 6 9 12 18 and 24 hours Data checking intervals Indoo...

Страница 24: ...shipping charges to the owner of the product to a USA address only Your La Crosse Technology Ltd warranty covers all defects in material and workmanship with the following specified exceptions 1 damag...

Страница 25: ...desired operation FCC ID OMO 01RX Receiver OMO 01TX sensor Freq 433 92 MHz La Crosse Technology Made in China WS 9115 All rights reserved This handbook must not be reproduced in any form even in excer...

Отзывы: