La Crosse Technology WS-9065TWC Скачать руководство пользователя страница 9

VIII. TIME 

SETTING

 

There are two methods by which the time and date can be set:   
A) Automatically via WWVB reception, or 
B) Manually. 

 

A.  WWVB (Remote Control Time) 

This method requires you to do nothing, except wait for the signal to be 
received, and to select a time zone. Reception usually takes approximately 10 
minutes during optimal conditions. The best condition for reception is at night, 
between midnight and 6:00 am—when there is less atmospheric interference.  
To keep your time as accurate as possible, the indoor weather station conducts 
a WWVB search every night between these hours, and overrides any manually 
set time. The WWVB tower icon (appearing in the TIME LCD) will flash 
when a signal-search is in progress and a signal is being received, and will 
remain steady when the signal has been received. If the WWVB time has not 
been received after 10 minutes of battery installation, you may manually set 
the time or leave the time function alone (reception will occur regardless). 
 

B.  MANUAL TIME SETTING 

Note:

 When in the 12-hour format “P.M” will appear to the left of the hour in 

the time LCD between the hours of noon and midnight. 
1. 

Press and hold the 

SET

 button for 5 seconds. 

2. 

“LCD” will show in the time LCD and the number setting will flash. 

3. 

Press and release the 

SET

 button five times. 

4. 

The time will flash in the time LCD. 

 

 
 
 
 

5. 

Press and release the 

IN

 button to advance the hours. 

6. 

Press and release the 

OUT

 button to advance the minutes. 

7. 

Press and release the 

SET

 button to confirm and advance to the year 

setting. 

 

IX.  SETTING THE YEAR, DAY AND MONTH 

Note:

  Reception of the WWVB signal will also set the date and day. The 

reception of the signal will override any programmed date and day. 

 

1. 

Press and hold the 

SET

 button for 5 seconds. 

2. 

“LCD” will show in the time LCD and the number setting will flash. 

3. 

Press and release the 

SET

 button six times. 

4. 

The year will flash in the date LCD. 

5. 

Press and release the 

IN

 button to advance the year. 

 

9

Содержание WS-9065TWC

Страница 1: ...WS 9065U Wireless 433 MHz Radio controlled Weather Station Instruction Manual...

Страница 2: ...2 24 hour Time Setting 8 Setting the Time 9 Setting the Year Day and Month 9 10 Setting the Snooze 10 Setting the Temperature Format 10 Setting the Forecast Sensitivity 10 11 Features Weather Forecast...

Страница 3: ...in Ft Collins Colorado and transmits the exact time and date signal continuously throughout the United States at 60 kHz The signal can be received up to 2 000 miles away through the internal antenna...

Страница 4: ...n a dry shaded area The remote temperature sensor has a range of 330 feet Any walls that the signal will have to pass through will reduce distance An outdoor wall or window can have up to 30 feet of r...

Страница 5: ...correct polarity and install 3 AA batteries 3 Replace the battery cover Note Immediately after the batteries have been installed the LCD Liquid Crystal Display will flash and a tone will sound Within...

Страница 6: ...ttings are as follows LCD Contrast 5 Time Zone 5 Eastern Daylight Saving Time 1 on Radio controlled time reception ON 12 24 hour time 12 Time 12 00 Year 2003 Day and Month 1 1 Snooze this function not...

Страница 7: ...please see the table on the next page It is possible to select any time zone from 12 GMT to 12 GMT for example to see the time in another country TIME ZONES GMT 0 Atlantic 4 EST Eastern 5 CST Central...

Страница 8: ...button three times 4 RCC will appear in the date LCD and ON or OFF will flash in the time LCD 5 Press and release the IN button to select radio controlled time on or off 6 Press and release the SET bu...

Страница 9: ...nstallation you may manually set the time or leave the time function alone reception will occur regardless B MANUAL TIME SETTING Note When in the 12 hour format P M will appear to the left of the hour...

Страница 10: ...the time LCD and the number setting will flash 3 Press and release the SET button nine times 4 Either F or C will flash in the time LCD 5 Press and release the IN button to select the temperature form...

Страница 11: ...tion Forecast icon Comfort Level Indicator The weather forecasting feature is estimated to be 75 accurate and is for the next 12 to 24 hours The weather forecast is based solely upon the change of air...

Страница 12: ...t changed or the change has been slow and gradual B WEATHER TENDENCY ARROWS Other possible displays in the FORECAST LCD are 2 weather tendency arrows one that points up on the left side of the LCD and...

Страница 13: ...with the humidity measured at that time and the time and date of occurrence are displayed The minimum records will display for 30 seconds before returning to the normal display mode 2 Press the IN but...

Страница 14: ...ir own set of instructions follow these instructions for a complete guide to setting up Following are some brief instructions for the basic set up of remote temperature sensor units with the WS 9065U...

Страница 15: ...you wish to reset Press and hold the OUT button for 5 seconds the records for the selected remote temperature sensor unit will be reset MOUNTING Note Before permanently mounting ensure that the indoo...

Страница 16: ...hat the screws are flush with the bracket 5 Insert the remote temperature sensor into the bracket B MOUNTING WITH ADHESIVE TAPE 1 With a nonabrasive solution clean and dry the back of the mounting bra...

Страница 17: ...indoor temperature station onto the screw using the hanging hole on the backside Gently pull the station down to lock the screw into place TROUBLESHOOTING NOTE For problems not solved please contact...

Страница 18: ...ffect of the display s case In addition the case can act as a heat sink to absorb and store heat from external sources i e handling of the case or radiant heat Also the much greater range of the outdo...

Страница 19: ...ndoor Temperature checking interval Every 10 seconds Indoor Humidity checking interval Every 1 minute Outdoor Temperature checking interval Remote Control Sender Every 1 minute Outdoor Temperature rec...

Страница 20: ...nter La Crosse Technology Ltd will pay reasonable return shipping charges to the owner of the product Your La Crosse Technology Ltd warranty covers all defects in material and workmanship with the fol...

Страница 21: ...ce must accept any interference received including interference that may cause undesired operation FCC ID OMO 01RX Receiver OMO 01TX transmitter Freq 433 92 MHz La Crosse Technology Made in China WS 9...

Отзывы: