background image

La Crosse Technology, Ltd.  

Page 11 

 

 

 

ACTIVATE ALARM: Press and release the ALM/DATE button to toggle between 

the alarm and day/date. When the alarm time and alarm icon ((.)) are showing 

to the right of the moon phase the alarm is activated. 

 

DEACTIVATE ALARM: When the alarm time and alarm icon ((.)) are showing to 

the right of the moon phase, the alarm is active. To deactivate the alarm press 

and release the ALM/DATE button and alarm icon ((.)) will disappear. When the 

day and date are showing, the alarm is off. 

 

Snooze Alarm 

 

 

ACTIVATE THE SNOOZE: while the alarm is sounding, press and release the 

SNOOZE/CH button. The snooze function is active for 10 minutes. The alarm will 

come back on after 10 minutes.   

 

DEACTIVATE THE SNOOZE: To deactivate the snooze function press and release 

any button other than either of the SNOOZE/CH buttons. 

 

Forecast Icons Inaccurate 

 

 

These icons forecast the weather in the next 48-60 hours. The forecast icons 

displayed, predict the weather in terms of getting better or worse and not 

necessarily sunny or rainy as each icon indicates.  

 

 

NOTE: After set up, disregard readings for weather forecasts for the next 48-60 

hours. This will allow sufficient time for the forecast station to collect air 

pressure data at a constant altitude and therefore result in a more accurate 

forecast.  

 

Forecast Arrows 

 

 

Working together with the weather icons is the Weather Tendency Indicators. 

When the Indicator Points Upwards, it means that the Air-pressure is increasing 

and the weather is expected to improve, but when Indicator Points Downwards, 

the Air-pressure is falling and the weather is expected to become worse.  

 

Barometric Pressure 

 

 

A sensor in the forecast station, not the outdoor sensor, reads the Barometric 

Pressure. A significant difference in pressure inside and pressure outside would 

create a vacuum. 

 

The numeric pressure value adjusts automatically as the forecast station reads 

changes in air pressure.  

 

In the 

program menu

 the unit can select the pressure unit of measure (inHg is 

common in the  

 

USA) and set the actual numbers on many displays. 

 

La Crosse Technology products will not read pressure correctly above 6200 ft. in 

elevation. 

 

Loss of Pressure is often a power-related problem, and it can be resolved by 

following these  

 

steps:  

Содержание WS-9057U-IT

Страница 1: ...rature Humidity Reading 4 Intermittent Outdoor Temperature Humidity 4 Outdoor Transmitter Fell and No Longer Works 4 Outdoor Transmitter Drains Batteries Quickly 5 Outdoor Temperature Humidity Is Stuc...

Страница 2: ...stable in performance Alkaline batteries manufactured this year will have an expiration date 10 years in the future Battery technology has improved and batteries will maintain voltage longer in storag...

Страница 3: ...ance resistance interference for details on mounting the outdoor transmitter Outdoor Temperature Humidity Transmitter Compatible Outdoor Transmitters The TX29UDTH IT TX21U IT TX44UDTH IT TX29UTH IT an...

Страница 4: ...vironments e g moister climates If transmitter signal is lost please wait 2 4 hours for the signal to reconnect on its own Move the outdoor transmitter to a closer location Check Channels The forecast...

Страница 5: ...y brands for both Alkaline and Lithium batteries Outdoor Temperature Humidity Is Stuck or OFL Check Batteries Overpowered or underpowered batteries can cause this reading Replace outdoor transmitter F...

Страница 6: ...e humidity and pressure When the reading appears in the outdoor temperature area move to the second transmitter Insert 2 AA batteries in the second outdoor transmitter The outdoor temperature area sho...

Страница 7: ...crews are flush with the bracket Insert the outdoor temperature sensor into the bracket Note Mounting with adhesive tape is not recommended as a permanent mounting solution Only use the adhesive tape...

Страница 8: ...issue Windows can reflect the radio signal Metal will absorb the RF radio frequency signal Stucco is held to the wall by a metal mesh Transmitting antennas ham radio emergency dispatch center airports...

Страница 9: ...for AM PM 24h for military time Press and release the SET button once to select hour HOUR The Hour will flash Use the OUT button to set the Hour If using 12 hour Time Mode be sure to check the hour f...

Страница 10: ...next to the forecast station for 2 hours Compare indoor and outdoor temperature humidity The temperature should be within 4 degrees to be within tolerance The humidity should be within 10 to be within...

Страница 11: ...as each icon indicates NOTE After set up disregard readings for weather forecasts for the next 48 60 hours This will allow sufficient time for the forecast station to collect air pressure data at a c...

Страница 12: ...he earth and sun so the illuminated portion of the moon is on the backside facing the sun and we cannot see it After a new moon the illuminated visible portion will increase or wax until the full moon...

Страница 13: ...r underpowered Remove batteries from Forecast Station Press any button 20 times Leave the batteries out of the display for 2 hours Forecast Station Display is Frozen On a brand new forecast station ch...

Страница 14: ...fe is over 12 months when using reputable battery brands Comfort Level Indicator The comfort level indicator appears in between the indoor temperature and humidity The indicator will display a happy f...

Отзывы: