background image

 

9

3.

 

Press and release the 

SET

 button ten times. 

4.

 

“Sn” will appear in the DATE LCD and a number will be flashing next to it. 

5.

 

Press and release the 

ALM/+

 button to select the duration of the snooze. 

 
 
 
 
 
 
 

Note:

  The snooze can be set for 0 to 30 minutes in 5-minute increments. If 0 minutes is selected 

pressing the 

WIND/SNZ

 button will deactivate the alarm and it will not come back on. 

6.

 

Press and release the 

SET

 button to confirm and advance to the forecast sensitivity setting. 

 

X.

 

SETTING THE FORECAST SENSITIVITY

 

Note:

  The forecast sensitivity can be adjusted to allow for areas that have a higher or lower 

sensitivity to changing air pressure (for example coastal areas have more pressure change than 
areas such as southern Arizona).   
 
The numbers correspond to the amount of air pressure change necessary to trigger a change in 
the forecast icon.  Areas that tend to have more air pressure change would set the sensitivity to 3, 
while areas that experience lower than normal air pressure change would set the sensitivity to 1. 

 
 
 
 
 
 
 
 

1.

 

Press and hold the 

SET

 button for 3 seconds. 

2.

 

“LCD” will show in the TIME LCD and the number setting will flash. 

3.

 

Press and release the 

SET

 button eleven times. 

4.

 

Either “1”, “2” or “3” will flash in the TIME LCD and the forecast icon and tendency arrows 
will flash in the FORECAST LCD. 

5.

 

Press and release the 

ALM/+

 button to select the forecast sensitivity. 

6.

 

Press and release the 

SET

 button to confirm the forecast sensitivity and complete the 

programming. 

 
 
 
 
 
 
 
FEATURES OF THE 

WS-9043U

 

 
 
 
 
 
 

WWVB Tower 
Icon (indicates 
time reception) 

Radio-controlled 
time icon 
(indicates radio-
controlled time 
turned on) 

Содержание WS-9043U

Страница 1: ...WS 9043U Wireless 433 MHz Radio controlled Weather Station Instruction Manual...

Страница 2: ...ing Radio controlled Time Setting 12 24 hour Time Setting Setting the Time Setting the Year Day and Month Setting the Snooze Setting the Forecast Sensitivity Features Weather Forecast Icons and Tenden...

Страница 3: ...be received up to 2 000 miles away through the internal antenna in the Weather Station However due to the nature of the Earth s Ionosphere reception is very limited during daylight hours The weather...

Страница 4: ...ave to pass through will reduce distance An outdoor wall or window can have up to 30 feet of resistance and an interior wall can have up to 20 feet of resistance Your distance plus resistance should n...

Страница 5: ...l usually at night it will display the correct time default time zone is Eastern You will need to adjust the time zone to match your local time PROGRAM MODE Programming Note If 15 seconds are allowed...

Страница 6: ...again 4 The time zone will flash in the DATE LCD 5 Press and release the ALM button to select your time zone Note It is possible to select any time zone from 12 GMT to 12 GMT for example to see the t...

Страница 7: ...flash in the TIME LCD 5 Press and release the ALM button to select radio controlled time on or off 6 Press and release the SET button to confirm and advance to the 12 24 hour time setting VI 12 OR 24...

Страница 8: ...ET button five times 4 The hours digits will flash in the TIME LCD 5 Press and release the ALM button to advance the hours 6 Press and release the SET button to confirm the hours setting and advance t...

Страница 9: ...uch as southern Arizona The numbers correspond to the amount of air pressure change necessary to trigger a change in the forecast icon Areas that tend to have more air pressure change would set the se...

Страница 10: ...ons that will be displayed in the FORECAST LCD Sunny indicates that the weather is expected to improve not that the weather will be sunny Sun with Clouds indicates that the weather is expected to be f...

Страница 11: ...erature Sensors The Heat Index and Dew Point will then be calculated from the received temperature humidity readings IV MINIMUM AND MAXIMUM TEMPERATURE HEAT INDEX AND DEW POINT RECORDS The WS 9043U ke...

Страница 12: ...display for 30 seconds before returning to the normal display mode 6 Press and release the OUT MIN button again once while MAX heat index is still displayed 6 times otherwise MIN appears with the hea...

Страница 13: ...in the DATE LCD 4 Press and release the OUT MIN button to adjust the minutes 5 Press and release the SNOOZE CH button to confirm the setting or wait for 15 seconds and the display will automatically...

Страница 14: ...ensor unit press and release the SNOOZE CH button A shift from one boxed number to the next should be observed in the OUTDOOR LCD 2 To view the Minimum Maximum temperature humidity heat index and dew...

Страница 15: ...ve the protective strip from the other side of the tape 5 Position the remote temperature humidity sensor in the desired location ensuring that the indoor weather station can receive the signal II THE...

Страница 16: ...s different However the difference can be exaggerated further because the sensors are designed for different working environments The indoor temperature sensor is less responsive to ambient air curren...

Страница 17: ...et 100 meters in open space Power Supply Indoor weather station 3 x AA IEC LR6 1 5V Remote temperature humidity sensor 2 x AA IEC LR6 1 5V Battery life cycle Approximately 12 months Recommended batter...

Страница 18: ...OMPLIES WITH PART 15 OF THE FCC RULES OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS 1 THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE AND 2 THIS DEVICE MUST ACCEPT INTERFERENCE RECEIVED INCLUDIN...

Страница 19: ...19...

Отзывы: