background image

 

 

TO INSTALL AND REPLACE BATTERIES IN THE WEATHER 
PROJECTION STATION 

The Weather Projection Station uses 3 x AA, 
IEC LR6, 1.5V batteries. To install and 
replace the batteries, please follow the steps 
below: 
1. 

Insert finger or other solid object in 
the space at the bottom center of the 
battery compartment and lift up to 
remove the cover. 

2. 

Insert batteries observing the correct 
polarity (see marking). 

3. Replace 

compartment 

cover. 

 
 

TO INSTALL AND REPLACE BATTERIES IN THE THERMO-
HYGRO  SENSOR

 

The Thermo-hygro sensor uses 2 x AA, IEC LR6, 1.5V batteries. To install and 
replace the batteries, please follow the steps below: 
1. 

Remove the battery cover. 

 
 

2. 

Insert the batteries, observing the correct 
polarity (see marking). 

3. 

Replace the battery cover on the unit.

 

 

Note: 

In the event of changing batteries in any of the units, 
all units need to be reset by following the setting up 
procedures. This is due to a random security code 
assigned by the sensor at start-up. This code must be 
received and stored by the Weather Projection Station 
in the first 3 minutes of power being supplied to the 
sensor.

 

 

BATTERY CHANGE: 

It is recommended to replace the batteries in all units on an annual basis to 
ensure optimum accuracy of these units. 

 

Please participate in the preservation of the environment. 
Return used batteries to an authorized depot. 

 

SETTING UP 

The Weather Projection Station can be either batteries-operated or 
powered by the provided AC-DC adapter. 

 

Содержание WS-9025U

Страница 1: ...y for technical mistakes or printing errors or their consequences All trademarks and patents are acknowledged FCC ID OMO 01RX receiver OMO 01TX sensor THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULE...

Страница 2: ...d time date calendar moon phase indoor and outdoor temperature indoor and outdoor relative humidity this unit will never keep you guessing on current and future weather conditions Operation of this pr...

Страница 3: ...MAX records and time of reception Indoor and outdoor temperature display in C F Humidity data with MIN MAX records Indoor and outdoor humidity display as RH Can receive up to 3 sensors Time projection...

Страница 4: ...move the battery cover 2 Insert the batteries observing the correct polarity see marking 3 Replace the battery cover on the unit Note In the event of changing batteries in any of the units all units n...

Страница 5: ...o sensors If you have purchased additional sensors repeat from step 3 for all extra sensors However ensure that you leave 10 seconds in between the reception of the last sensor and the set up of the f...

Страница 6: ...the moon icon the weather icons sun and clouds will be displayed If the indoor temperature and indoor humidity are not displayed after 15 seconds remove the batteries and wait for at least 3 minutes b...

Страница 7: ...ception attempt will occur on the following day Please refer to notes on About WWVB Radio controlled Time and Manual Time Setting Your Weather Projection Station is now operational Note If the Weather...

Страница 8: ...ure for every 5 seconds 3 Adjust the projection image in an upright position with the key Note If more than one Thermo hygro Sensor is used only the temperature from sensor 1 will be projected Note Th...

Страница 9: ...ime which is also known as Greenwich Mean Time GMT This time does not follow Daylight Saving Time changes After the top of the minute a tone will sound for every second It is possible that your Weathe...

Страница 10: ...age direction can display 4 different orientations Back light on DISPL key Toggle between the time and outdoor temperature or automatic alternates time outdoor temperature every 5 seconds display mode...

Страница 11: ...ss and hold for 4 seconds to reset the MIN MAX records for selected channel Press to set the alarm minute inside alarm setting mode Stop the alarm during alarm ringing Stop snooze mode Back light on A...

Страница 12: ...digit starts flashing 2 Use the CH key to view all levels of contrast 3 Select the desired LCD contrast Confirm with the SET key and enter in the Time Zone setting TIME ZONE SETTING The time zone defa...

Страница 13: ...n can be turn OFF The clock will then work as a normal Quartz clock Default setting is ON 1 The digit ON will start flashing on the LCD 2 Use the CH key to turn OFF the time reception function 3 Confi...

Страница 14: ...on attempts the WWVB tower icon will flash If reception has been unsuccessful then the WWVB tower icon will not appear but reception will still be attempted the following hour CALENDAR SETTING The dat...

Страница 15: ...how temperature data in F or C Default F 1 Use the CH key to toggle between F or C 2 Confirm with the SET key and enter the Weather forecasting icon sensitivity setting WEATHER FORECASTING ICON SENSIT...

Страница 16: ...m is ringing by pressing the SNOOZE key However the snooze will only be activated when the snooze time is set other than OFF in snooze setting Otherwise the snooze function will not be activated When...

Страница 17: ...AST AND WEATHER TENDENCY WEATHER FORECASTING ICONS Weather icons in the third section of LCD that can be displayed in any of the following combinations Sunny Cloudy with sunny intervals Rainy For ever...

Страница 18: ...stly sunny If the Weather Projection Station is moved to another location significantly higher or lower than its initial standing point for example from the ground floor to the upper floors of a house...

Страница 19: ...d data will also be displayed in the time and calendar sections for temperature data only 2 To reset the MIN MAX data press and hold the HOUR IN key for about 4 seconds This will reset all recorded in...

Страница 20: ...r sensor TO EXIT THE MANUAL SETTING MODE To exit the manual setting mode anytime during the manual setting modes press the SNOOZE key anytime or wait for automatic timeout The mode will return to norm...

Страница 21: ...ers from the sensor to the Weather Projection Station in open space However this depends on the surrounding environment and interference levels If no reception is possible despite the observation of t...

Страница 22: ...esolution OFL displayed if outside this range Relative humidity measuring range Indoor and outdoor 1 to 99 with 1 resolution displayed if outside this range Indoor temperature checking interval every...

Страница 23: ...o charge as stipulated herein with new or reconditioned parts or products if found to be defective during the limited warranty period specified above All replaced parts and products become the propert...

Страница 24: ...ILL NOT ASSUME LIABILITY FOR INCIDENTAL CONSEQUENTIAL PUNITIVE OR OTHER SIMILAR DAMAGES ASSOCIATED WITH THE OPERATION OR MALFUNCTION OF THIS PRODUCT THIS PRODUCT IS NOT TO BE USED FOR MEDICAL PURPOSES...

Отзывы: