background image

 

20

5.

 

Remove screws from the mounting surface. 

6.

 

Align the mounting bracket with the started screw holes. 

7.

 

Screw mounting bracket onto the mounting surface. The 

screws should be flush with the bracket. 

8.

 

Fit the mounting post (on the back of the remote 

thermo/hygro sensor) into the receptor of the mounting 
bracket. 
 

B.

 

Mounting With Adhesive Tape 

 

1.

 

With a nonabrasive solution, clean and dry the back of 

the mounting bracket and the mounting surface to ensure 
a secure hold.  The mounting surface should be smooth 
and flat. 

2.

 

Remove the protective strip from one side of the tape.  

Press firmly onto the designated area on the back of the 
mounting bracket. 

3.

 

Remove the protective strip from the other side of the 

tape, and situate the mounting bracket.  Firmly press the 
mounting bracket onto the mounting surface. 

4.

 

Fit the mounting post into the receptor of the mounting 

bracket. 

 

Содержание WS-7390U

Страница 1: ...WS 7390U Wireless 433 MHz Radio controlled Weather Station Instruction Manual...

Страница 2: ...11 Daylight Saving Time DST Setting 11 12 Setting Day Date and Year 12 13 Selecting F or C 13 Setting the LCD Contrast 13 Features Weather Forecast Icons 14 15 Indoor Temperature Humidity Comfort Lev...

Страница 3: ...NTS 1 The indoor weather station 2 Remote temperature sensor model TX4U 3 Instruction manual and warranty card ADDITIONAL EQUIPMENT not included 1 Four fresh AA 1 5V alkaline batteries 2 Phillips scre...

Страница 4: ...eception is very limited during daylight hours The indoor weather station will search for a signal every night when reception is best The WWVB radio station derives its signal from the NIST Atomic clo...

Страница 5: ...the indoor temperature and humidity and the outdoor temperature and humidity If the indoor weather station does not display all values after the 10 minutes please retry the set up as stated above Afte...

Страница 6: ...remote thermo hygro sensor transmits a signal every 3 minutes after the batteries have been installed the indoor weather station will search for the signal for a duration of 5 minutes If there is no...

Страница 7: ...at the lower central position of the battery cover then push up and pull out on the battery cover 2 Observe the correct polarity and install 2 AA batteries 3 Replace the battery cover Note Immediatel...

Страница 8: ...one default is Eastern Time Zone Reception usually takes approximately 6 8 minutes during optimal conditions The best conditions for reception is at night between midnight and 6 00 am when there is le...

Страница 9: ...temperature sensors if added and the RESET button for resetting the minimum and maximum temperatures The two back buttons are the SET button to enter the programming mode and confirming selections and...

Страница 10: ...urs If the time is not within the PM hours nothing will be displayed Be sure to set the time to the correct AM PM time to ensure automatic reception 4 Press and release the SET button the digits that...

Страница 11: ...n 7 PST Pacific 8 ALA Alaska 9 HAW Hawaii 10 4 Press and release the SET button to confirm and advance to the Daylight Saving Time setting skip step 1and 2 in section IV if continuing IV Daylight Savi...

Страница 12: ...24h flashes 2 Press the SET button 5 more times to reach the day of the week setting mode 3 The two digit day of the week is flashing SU is the default or factory setting 4 Press and release the butto...

Страница 13: ...ess and release the button to select F to C 5 Press the SET button to confirm and to advance to the LCD setting skip step 1 and 2 of section VII if continuing VII Setting the LCD Contrast 1 Press and...

Страница 14: ...icons that will be displayed in the TENDENCY LCD Sunny indicates that the weather is expected to improve not that the weather will be sunny Sun with Clouds indicates that the weather is expected to be...

Страница 15: ...e worse or remain poor No arrow means the pressure is stable A storm can be expected if there is a drop of 4 hPa or more in less than 6 hours the rain icon is displayed and the downward pointing arrow...

Страница 16: ...mum and Maximum Temperature Records Indoor Outdoor and Resetting The WS 7390U keeps a record of the minimum and maximum temperatures for both the indoor and outdoor sections These temperatures can be...

Страница 17: ...the remote sensors and in numeric sequence Second install batteries into the indoor weather station Transmission problems will arise if this is not done correctly and if the total time for set up exce...

Страница 18: ...ved in the OUTDOOR LCD 2 The minimum and maximum temperature of the additional remote sensor will be displayed below the current temperature of the remote sensor in the OUTDOOR LCD 3 To reset the mini...

Страница 19: ...t the remote thermo hygro sensor on a North facing wall The transmitting range of the remote thermo hygro sensor is 80ft Obstacles such as walls concrete and large metal objects can reduce the range P...

Страница 20: ...ve Tape 1 With a nonabrasive solution clean and dry the back of the mounting bracket and the mounting surface to ensure a secure hold The mounting surface should be smooth and flat 2 Remove the protec...

Страница 21: ...he display on your wall 2 Fix a screw not included into the desired wall leaving approximately 3 16 of an inch 5mm extended from the wall 3 Place the indoor weather station onto the screw using the ha...

Страница 22: ...and date are correct Solution Be sure correct time zone and daylight saving time are selected Problem The LCD is faint Solution 1 Set the LCD contrast to a higher number 2 Replace batteries Problem No...

Страница 23: ...rosse Technology for repairs Specifications Temperature measuring range Indoor 32 F to 139 8 F with 0 2 F resolution 0 C to 59 9 C with 0 1 C resolution OFL displayed if outside this range Outdoor 21...

Страница 24: ...nly to the original purchaser of this product To receive warranty service the purchaser must contact La Crosse Technology Ltd for problem determination and service procedures Warranty service can only...

Страница 25: ...r 3 damage to or deterioration of any accessory or decorative surface 4 damage resulting from failure to follow instructions contained in your owner s manual 5 damage resulting from the performance of...

Страница 26: ...osse Technology 2809 Losey Blvd S La Crosse WI 54601 Phone 608 782 1610 Fax 608 796 1020 e mail support lacrossetechnology com warranty work sales lacrossetechnology com information on other products...

Отзывы: