background image

DETAILED SET-UP GUIDE 
 
BATTERY INSTALLATION 
 

A.  Remote Thermo/hygro Sensor

 

1.  Pull the cylindrical rain cover off the remote 

thermo/hygro sensor. 

2.  Remove the battery cover (located on the backside 

of the remote thermo/hygro sensor, above the 
mounting post and bracket). 

3.  Press the arrow and slide the battery cover off. 
4.  Observing the correct polarity install 2 AA 

batteries. 

5.  Replace battery cover, and place rain cover snugly onto the remote 

thermo/hygro sensor. 

 

B.  Indoor Weather Station 

1.  Remove the battery cover.  To do this, insert a 

solid object in the space provided at the lower-
central position of the battery cover, then push 
up and pull out on the battery cover. 

Battery 
Cover 

2.  Observe the correct polarity, and install 2 AA 

batteries. 

3. 

Replace the battery cover.

 

 

Note:

  Immediately after the batteries have been installed, each LCD 

(Liquid Crystal Display) will flash, and a tone will sound.  Within a few 
seconds the indoor temperature, indoor relative humidity, and the 
weather icons (sun and clouds) will be displayed.  If these items are not 
displayed remove the batteries for 10 seconds and reinstall. If the 
outdoor temperature is not displayed within four minutes, remove the 
batteries from both units, wait 10 seconds, and reinstall.  The time will 
show -:-- and start searching for the signal. If it successfully receives 
the time signal (reception is achieved easiest at night), it will display the 
correct time (factory setting is Eastern time zone). 

 

 
 
 

 

6

Содержание WS-7078TWC

Страница 1: ...WS 7078TWC Wireless 433 MHz Radio controlled Weather Station Instruction Manual...

Страница 2: ...11 Setting Day Date and Year 11 12 Selecting F or C 12 Setting the LCD Contrast 12 Features Weather Forecast Icons 13 14 Indoor Temperature Humidity Comfort Level Indicator 15 Outdoor Temperature Humi...

Страница 3: ...gure 2 3 3 Three each Philips screws 4 One strip double sided adhesive tape 5 Instruction manual and warranty card Figure 1 Time LCD Date LCD Forecast LCD Indoor LCD Outdoor LCD Figure 2 ADDITIONAL EQ...

Страница 4: ...sphere reception is very limited during daylight hours The weather station will search for a signal every night when reception is best The WWVB radio station derives its signal from the NIST Atomic cl...

Страница 5: ...can place your remote thermo hygro sensor outdoors and set your time The remote thermo hygro sensor should be placed in a dry shaded area The remote thermo hygro sensor has a range of 80 feet Any wal...

Страница 6: ...hen push up and pull out on the battery cover Battery Cover 2 Observe the correct polarity and install 2 AA batteries 3 Replace the battery cover Note Immediately after the batteries have been install...

Страница 7: ...o leave the program sequence or want to program a specific setting follow each instructional step to program that setting The programming sequence is as follows 12 or 24 Hour Time Setting Time Zone Se...

Страница 8: ...the SET button for 3 seconds or until 12h or 24h flashes in the DATE LCD 2 Press and release the SET button 1 time to enter the Time Zone setting mode 3 The default Time Zone 5 will flash in the DATE...

Страница 9: ...on 2 times to reach the DST selection mode 3 DST 1 is the default factory setting and will be flashing in the DATE LCD 4 Press and release the CH button to select DST 0 or DST 1 DST 0 indicates that t...

Страница 10: ...search is in progress will remain steady when the signal has been received and nothing will be displayed in all other situations If the WWVB time has not been received 10 minutes after battery instal...

Страница 11: ...signal is received However the day date and year can be manually set and will flash respectively in the DATE LCD during manual programming 1 Press and hold the SET button for 3 seconds or until 12h or...

Страница 12: ...lease the SET button to confirm your selection and to advance to the LCD contrast setting G Setting the LCD Contrast Note There are 8 LCD contrast levels to choose from Lcd 0 is the lightest and Lcd 7...

Страница 13: ...The weather forecast is based solely upon the change of air pressure over time The WS 7078UF averages past air pressure readings to provide an accurate forecast creating a necessity to disregard all...

Страница 14: ...t will not change from sunny directly to rainy although it is possible for the change to occur quickly If the symbols do not change then the weather has not changed or the change has been slow and gra...

Страница 15: ...of the temperature This indicates which remote thermo hygro sensor unit 1 2 or 3 is currently displaying its data in the OUTDOOR LCD This feature is explained in further detail in section VI Adding R...

Страница 16: ...Press and release the OUT button once 2 MIN appears in the upper center location of the flashing OUTDOOR LCD indicating that the minimum temperature and the time and date of occurrence are displayed T...

Страница 17: ...the DATE LCD as normal 5 The 1 icon appearing in the DATE LCD indicates that the alarm is set to sound at the programmed time Note Programming the alarm time automatically activates the alarm to soun...

Страница 18: ...ensors can be purchased through the same dealer as this indoor weather station or by contacting La Crosse Technology directly A TX4U will monitor temperature and humidity a TX3U will monitor temperatu...

Страница 19: ...ect which remote thermo hygro sensor to read data from indicated by the boxed number then press and release the OUT button 3 Pressing and releasing the OUT button once will display the minimum tempera...

Страница 20: ...The transmitting range of the remote thermo hygro sensor is 80ft Obstacles such as walls concrete and large metal objects can reduce the range Place both units in their desired location and wait appro...

Страница 21: ...acket onto the mounting surface 4 Fit the mounting post into the receptor of the mounting bracket The Indoor Weather Station A The indoor weather station can be mounted in two ways with the table stan...

Страница 22: ...problems contact La Crosse Technology Problem Hour is incorrect minute and date are correct Solution Be sure correct time zone and daylight saving time are selected Problem The LCD is faint Solution...

Страница 23: ...displays and units with a soft damp cloth Do not use solvents or scouring agents they may mark the displays and casings Do not submerge in water Immediately remove all low powered batteries to avoid l...

Страница 24: ...ry 10 seconds Indoor Humidity checking interval Every 1 minute Outdoor Temperature and Humidity checking interval Remote Thermo hygro Sensor Every 1 minute Outdoor Temperature and humidity reception I...

Страница 25: ...irs faulty batteries or the indoor weather stations inability to receive a signal due to any source of interference LA CROSSE TECHNOLOGY WILL NOT ASSUME LIABILITY FOR INCIDENTAL CONSEQUENTIAL PUNITIVE...

Страница 26: ...TIONS 1 THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE AND 2 THIS DEVICE MUST ACCEPT INTERFERENCE RECEIVED INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION All rights reserved This handbook m...

Отзывы: