7 Weather 

Tendency 

 
Call up the tendency display by touching the weather symbol in the TENDENCY section.    

 
 
 
 
 
 

The text section (last two lines on the LCD) will show since when (with time and date) the weather 
condition corresponds to the presently displayed weather symbol Sunny, Fair (Cloudy with sunny 
intervals) or Rainy.   

 
 
 
 

 

Air Pressure History 

(Pressure History)

 

 
 
 
 
 

The air pressure history shows the progress of the air pressure over a time period of 24 or 72 
hours in form of a 7-step bar graph, where the length of the utmost right bar represents the 
present air pressure and the remaining bars show the progress of the air pressure with regard to 
the present air pressure.   

 

Note:

 The time resolution of the bar graph can be changed from fine (0 to -24 h) to coarse (0 to -

72 h) and back by touching the PRESSURE HISTORY section once.    

 

Operating and Setting of the following Functions: 

 

 

Air Pressure 

(Pressure), Relative and Absolute 

 

Indoor Temperature

 (Indoor Temp) 

 

Indoor Humidity

 (Indoor Humidity) 

 

Outdoor Temperature

 (Outdoor Temp), 

Wind Chill

Dew Point

 

 

Outdoor Humidity 

(Outdoor Humidity) 

 

Wind Speed

,

 Wind Gust 

 

Important Note! 
Since operating procedures and settings are identical for all of the functions above, all 
steps to be carried out on the Touch Screen Weather Station for above functions shall be 
explained only once by means of the following example “Air Pressure”.    

 

9.1  

Air Pressure 

(Pressure) 

 

Example for Activating the Displays of Stored Maximum Values 

Call up the menu on the text section by touching the PRESSURE field.   
 
 

 

Start with 

٭

MAX

٭

 in the menu section. 

Note:

 Display of the stored minimum values is possible from here in the same fashion by touching 

the 

٭

MIN

٭

 field.  

 

   
 

After touching *MAX*, the stored value is displayed.  Proceed by touching the 

٭

MAX 

PRESSURE

٭

 field. 

 
 
 

Содержание WS-3610

Страница 1: ...perating and Setting of various Functions 9 1 Air Pressure 10 Operating and Setting of the Rain Function 11 Additional Information Outdoor Temperature Display 12 Additional Information Wind Display 12...

Страница 2: ...otes generally applicable All actions and functions of the Weather Station are started on the Touch Screen by slightly touching not pressing the switching areas appearing in star symbols only in the t...

Страница 3: ...er to the Base Station and then plug it into an AC outlet When the AC adapter is used batteries may also be placed in the Base Station to serve as a backup in case of power outage Note In both cases i...

Страница 4: ...properly together at their chosen mounting or standing locations If there appear to be problems with the 433 MHz radio transmission they can typically be overcome by moving the Thermo Hygro Sensor No...

Страница 5: ...Relative Air Pressure Rel Pressure To be set to locally valid reference air pressure with regard to the local height above sea level Default 29 91 inHg Weather Tendency Tendency Weather Tendency sensi...

Страница 6: ...values can also be recalled individually by touching the respective area of the display Example Touching the indoor display will display the menu shown below Min Max and Alarm values can then be disp...

Страница 7: ...e NIST website at http www boulder nist gov timefreq stations wwvb htm The Radio Controlled WWVB Clock is normally controlled by the radio signal of the WWVB time code transmitter and will thus set ti...

Страница 8: ...by touching the PRESSURE HISTORY section once 9 Operating and Setting of the following Functions Air Pressure Pressure Relative and Absolute Indoor Temperature Indoor Temp Indoor Humidity Indoor Humi...

Страница 9: ...rtains to the presently displayed value End of Example Note Touching the PRESSURE section twice toggles the displays of the Relative rel and Absolute abs air pressure All setting and display facilitie...

Страница 10: ...Note Touch the OUTDOOR field twice to toggle the display between the following Outdoor Temperature Outdoor Temp Wind Chill Dew Point All setting and display facilities only pertain to the presently d...

Страница 11: ...nd displayed time and weather data to be transferred to a PC via a Com port connection The supplied software provides complete history data sets data graphing and web update capability 14 1 Data Stora...

Страница 12: ...g Interval Thermo Hygro Sensor 32 s 15 4 Indoor Data Measuring Interval Indoor Data every 20 s Temperature Range 14 2 F to 139 8 F Display OFL outside this range Resolution approx 0 5 F Measuring Rang...

Страница 13: ...rges incurred in getting your La Crosse Technology Ltd product to a La Crosse Technology Ltd authorized service center La Crosse Technology Ltd will pay reasonable return shipping charges to the owner...

Страница 14: ...on video at www lacrossetechnology info 3610 All rights reserved This handbook must not be reproduced in any form even in excerpts or duplicated or processed using electronic mechanical or chemical pr...

Отзывы: