15 Technical 

Data 

   

15.1   Outdoor Data: 

Transmission Range in Open Field: .... up to. 330 ft max. 
Measuring Interval Outdoor Data: ....... every 20 s 
Temperature Range: ........................... -40 °F to 139.8 °F (Display “OFL” outside this range) 
Resolution:........................................... approx. 0.5 °F 
Measuring Range Rel. Humidity:......... 1% to 99%

 

Resolution:........................................... 1% 
Rain Volume Display: .......................... 0 to 39.4 in (1 hr, 24 hrs.) 
 

0 to 98.4 in (last week, last month) 

 

0 to 393.7 in (total volume) 

Resolution:........................................... approx. 0.02 in 
Wind Speed ......................................... 0 to 111.8 mph or 1 to 50 m/s 
Resolution:........................................... 0.1 m/s 
Wind Direction: .................................... Graphic Resolution 22.5 Degrees, 
 

Numeric Resolution Character Format 

 

15.2   Data Transmission by 433 MHz Signal: 

Measuring Interval Thermo-Hygro Sensor: ......................  
128 s (at Wind speed 

 6.2 mph) or 32 s (at Wind speed > 6.2 mph, or on Wind Gust display); 10 

Min.

 

(if the Base Station does not receive any data after 5 successive attempts all outdoor 

displays except the rain amount revert to “---“) 

 

15.3   Data Transmission by Cable: 

Measuring Interval Thermo-Hygro Sensor: ......... 32 s 

 

15.4   Indoor Data: 

Measuring Interval Indoor Data: .......... every 20 s 
Temperature Range: ........................... 14.2 °F to 139.8 °F (Display “OFL” outside this range) 
Resolution:........................................... approx. 0.5 °F 
Measuring Range Rel. Humidity:......... 1% to 99%  

 

Resolution:........................................... 1% 
Measuring Range Air Pressure: .......... 8.86 inHg to 32.45 inHg 
Resolution:........................................... 0.003 inHg 

 

Alarm Duration:.................................... about 2 minutes 

 
 

15.5     Power Supply: 

Base Station: 
Batteries:.............................................. 3 ea. 1.5 V Batteries Type AA, IEC LR6 (Alkaline Batteries 

recommended, Life Cycle without EL backlight approx. 1 
year)  

or AC power:........................................ AC Adapter INPUT 120VAC / 60HZ (use only the included 

AC Adapter. 

Recommended for PC Connection and 

frequent use of EL Backlight

)   

 

Thermo-Hygro-Sensor: 
Batteries:.............................................. 2 ea. 1.5 V Batteries Type C (Alkaline Batteries 

recommended, Life Cycle approx. 2.5 years)   

or.......................................................... Power provided via Cable from the Base Station by using 

the AC Adapter   

 

15.6 PC 

Connection: 

Wiring:.................................................. COM Port Cable (included) 
Data Processing: ................................. by PC only 
Software:.............................................. “Heavy Weather Pro 3600“ (included) 
Storage Intervals: ................................ 1 min through 12 h, settable 
Data Volume: 
Base Station: ....................................... 1750 Data Sets max. in Ring Buffer EEPROM 
PC:....................................................... Volume of Main Memory max. 

Содержание WS-3610

Страница 1: ...perating and Setting of various Functions 9 1 Air Pressure 10 Operating and Setting of the Rain Function 11 Additional Information Outdoor Temperature Display 12 Additional Information Wind Display 12...

Страница 2: ...otes generally applicable All actions and functions of the Weather Station are started on the Touch Screen by slightly touching not pressing the switching areas appearing in star symbols only in the t...

Страница 3: ...er to the Base Station and then plug it into an AC outlet When the AC adapter is used batteries may also be placed in the Base Station to serve as a backup in case of power outage Note In both cases i...

Страница 4: ...properly together at their chosen mounting or standing locations If there appear to be problems with the 433 MHz radio transmission they can typically be overcome by moving the Thermo Hygro Sensor No...

Страница 5: ...Relative Air Pressure Rel Pressure To be set to locally valid reference air pressure with regard to the local height above sea level Default 29 91 inHg Weather Tendency Tendency Weather Tendency sensi...

Страница 6: ...values can also be recalled individually by touching the respective area of the display Example Touching the indoor display will display the menu shown below Min Max and Alarm values can then be disp...

Страница 7: ...e NIST website at http www boulder nist gov timefreq stations wwvb htm The Radio Controlled WWVB Clock is normally controlled by the radio signal of the WWVB time code transmitter and will thus set ti...

Страница 8: ...by touching the PRESSURE HISTORY section once 9 Operating and Setting of the following Functions Air Pressure Pressure Relative and Absolute Indoor Temperature Indoor Temp Indoor Humidity Indoor Humi...

Страница 9: ...rtains to the presently displayed value End of Example Note Touching the PRESSURE section twice toggles the displays of the Relative rel and Absolute abs air pressure All setting and display facilitie...

Страница 10: ...Note Touch the OUTDOOR field twice to toggle the display between the following Outdoor Temperature Outdoor Temp Wind Chill Dew Point All setting and display facilities only pertain to the presently d...

Страница 11: ...nd displayed time and weather data to be transferred to a PC via a Com port connection The supplied software provides complete history data sets data graphing and web update capability 14 1 Data Stora...

Страница 12: ...g Interval Thermo Hygro Sensor 32 s 15 4 Indoor Data Measuring Interval Indoor Data every 20 s Temperature Range 14 2 F to 139 8 F Display OFL outside this range Resolution approx 0 5 F Measuring Rang...

Страница 13: ...rges incurred in getting your La Crosse Technology Ltd product to a La Crosse Technology Ltd authorized service center La Crosse Technology Ltd will pay reasonable return shipping charges to the owner...

Страница 14: ...on video at www lacrossetechnology info 3610 All rights reserved This handbook must not be reproduced in any form even in excerpts or duplicated or processed using electronic mechanical or chemical pr...

Отзывы: