background image

 

HOW TO INSTALL AND REPLACE THE BATTERIES INTO THE 
WEATHER CENTER 

The Weather Center works with 3 x AA, IEC LR6, 1.5V 
Alkaline batteries. When the batteries need to be replaced, 
the low battery symbol will appear on the LCD. To install 
and replace the batteries, please follow the steps below: 
1. 

Remove the battery compartment cover. 

2. 

Insert the batteries observing the correct polarity 
(see the marking in the battery compartment). 

3. Replace 

the 

battery 

cover. 

 

 

 
BATTERY CHANGE: 

It is recommended to replace the batteries in all units every 24 months to ensure 
optimum accuracy of these units. 

 

 

Please participate in the preservation of the environment. Return 
used batteries to an authorized depot. 

 

Note: 

The stored History record will not be kept after the battery change is done on the 
Weather Center.

 

 
 
 
 
 

 

10

FUNCTION KEYS: 

 

Weather Center: 

The Weather Center has 5 easy-to-use function keys.

 

 
 
 
 
 
 
 
 
 
 
 

 

SET key 

 

Press and hold to enter manual setting modes: LCD contrast, Manual time 
setting, 12/24 hour time display, Calendar setting, ºF/ ºC temperature unit, Wind 

SET 
key 

+ key 

HISTORY key 

ALARM key 

MIN/MAX key 

 

11

speed unit, Rainfall unit, Pressure unit, Relative pressure reference setting, 
Weather tendency threshold setting, Storm warning threshold setting and Storm 
Alarm On/ Off setting 

 

Press to toggle between the display of Mode 1 or Mode 2:

 

Mode 1:

 "Wind speed + outdoor temp + rel. pressure" 

Mode 2:

 "Gust + Dew Point temp + rainfall" If pressure is showing with wind 

gust, press the plus button to view 24 hour and total rain. 
(Mode 2 displayed will be shown for 30 seconds. Then it will return to normal 
display automatically.) 

 

In normal display mode, press and hold to switch on/ off the Buzzer 

 

In the weather alarm setting mode, press and hold to adjust different alarm 
value and switch the alarm On/ Off 

 

Press to activate the reset mode when max or min record is shown 

 

Stop the alarm during the time alarm or weather alarm ringing

 

 

+ key

 

 

In display Mode 1, press to toggle between the display of Preset alarm time, 
date, w date, Indoor temp, or second in the time display 

 

In display mode 2, press to toggle between the display of Rel. Pressure, 24 hour 
rainfall and Total rainfall 

 

Press to adjust (increase) the level of different settings 

 

Stop the alarm during the time alarm or weather alarm ringing 

 

Press to confirm to reset the max/min record

 

 

Press to reset the total rainfall amount to 0

 

 

HISTORY key

 

 

Press to display the weather data history records 

 

Stop the alarm during the time alarm or weather alarm ringing 

 

12

 

Press to exit manual setting mode and alarm setting mode

 

 

ALARM key 

 

Press to enter the time alarm and weather alarm setting mode 

 

Confirm particular alarm setting 

 

Press to exit the manual setting mode 

 

Stop the alarm during the time alarm or weather alarm ringing 

 

Press to exit max/ min record display mode

 

 

MIN/MAX key 

 

Press to display minimum and maximum records of various weather data 

 

Press to adjust (decrease) the level of different settings 

 

Stop the alarm during the time alarm or weather alarm ringing 

 

LCD SCREEN 

The LCD screen is split into 5 sections displaying the following information: 
1. 

Time and date/ indoor temp/ second 

2. Wind 

data 

3. 

Outdoor temperature, Dew point and humidity, 

4. 

Air pressure, Rainfall data,  

5. 

Air pressure history and Weather forecast icon. 

 
 
 
 
 
 
 

Содержание TX31U-IT

Страница 1: ...ermo hygro sensor Wireless transmission at 915 MHz thermo hygro and rain sensor to the Weather Center Weather Center Wind sensor Rain sensor Rain Sensor TX32U IT 1 Base and funnel 1 2 x Screws and Pla...

Страница 2: ...weather center will never receive signal successfully from the transmitters In this case user will need to reinstall the batteries from all the transmitters to redo set up procedure After batteries ar...

Страница 3: ...30 seconds Then it will return to normal display automatically In normal display mode press and hold to switch on off the Buzzer In the weather alarm setting mode press and hold to adjust different al...

Страница 4: ...reception icon is showing the condition of the reception of the signal from Thermo hygro transmitter 15 Mode 2 Wind Gust Dew Point temperature and Rainfall reading are shown MANUAL SETTING The follow...

Страница 5: ...set as inch or mm The default unit is mm 1 Use the or MIN MAX key to toggle between the unit inch or mm 2 Confirm the unit with the SET key and enter the RELATIVE AIR PRESSURE UNIT SETTING RELATIVE A...

Страница 6: ...in Then press shortly the SET key to switch on or off the time alarm The showing of the icon means that the time alarm is switched on 6 Press the HISTORY key or wait for about 30 seconds and the displ...

Страница 7: ...he lack of reasonable and necessary maintenance 2 damage occurring during shipment claims must be presented to the carrier 3 damage to or deterioration of any accessory or decorative surface 4 damage...