La Crosse Technology K2-100 Скачать руководство пользователя страница 9

GB

GB

GB

GB

29

30

6.1 Barometer Mode

 - Barometric Pressure Graph Display

Barometric Pressure 

Graph Display

Temperature
in degree Celsius

Barometric 
Pressure

Barometric Pressure 
History Graph

Real time

C (Celsius) 

hPa/mb

C (Celsius) 

inHg

F(Fahrenheit)

inHg

F (Fahrenheit)

hPa/mb

hold 

lap/reset

hold 

lap/reset

hold 

lap/reset

hold 

lap/reset

Unit  Selection  Sequence

Barometric Pressure Graph Display

-

In the Barometric Pressure Graph Display, the 1st row of 
the display  shows the pressure history graph of the last 
48 hours.

T h e   2 n d   r o w   o f   t h e  d i s p l a y   s h o w s   t h e   B a r o m e t r i c 
Pressure and the current temperature. 

-

The 3rd row of the display shows the current time: 

 hour 

minute and second.

The Barometric Pressure History Graph

-  T h e  

K 2 - 1 0 0

  s t o r e s   t h e   B a r o m e t r i c   p r e s s u r e   v a l u e s  

a u t o m a t i c a l l y   a s   t h e   t i m e   g o   b y .  

The Barometric Pressure history graph of the Barometric 
Graph Display is plotted on these pressure values.

-

-

The X-axis of the history graph is time variable; the Y-
axis of the history graph is barometric pressure  variable. 
The Barometric Pressure History  Graph 

is 

ma

de

 up  

of 

11 rows and  40 columns.

-

T h e   m e m o r y   c o l u m n s   o n   t h e  l e f t   h a n d   s i d e   o f   t h e 
history graph are recorded earl

ier

  than those on the right.

-

The scale of the history graph is changeable, the scale 
will be changed in order to fit in the Barometric Pressure 
values. Check the 'Barometric Pressure History Graph 
Scale' section for more detail on the scale of  the history 
graph.

To Switch among Units

- The 

K2-100

 can display pressure in millibar (mb) hecto

-

Press and hold the [lap/reset] button to change the units
as in the units select sequence.

p a s c a l   ( h P a )   o r   i n c h   m e r c u r y   ( i n H g ) ;   t h e  

K 2 - 1 0 0

can display temperature in Celsius ( C) or Fahrenheit ( F).

C (Celsius) 

hPa(mb)

C (Celsius) 

inHg

F(Fahrenheit)

inHg

F (Fahrenheit)

hPa(mb)

hold 

lap/reset

hold 

lap/reset

hold 

lap/reset

hold 

lap/reset

Unit  Selection  Sequence

hold 

lap/reset

lap/reset

button

Graph Scale Display

6.0 Barometer and its sub-displays ... 

continue

 

Barometric Graph Display

31

32

6.2 Barometer Mode 

- Pressure History Graph Scale 

 

Pressure History Graph Scale

-

T h e   s c a l e   o f   t h e   Y - a x i s  o f   t h e   H i s t o r y   G r a p h   i s 
changeable for fitting all t he pressure memory into the 
graph. 

-

Press the [lap/reset] button once to view t he pressure 
s c a l e   i n f o r m a t i o n ,   i n   t h e   B ar o m e t r i c   P r e s s u r e   G r a p h  
Display,

-

The '

GRAPH SCALE

' message will slide out and display 

for 3 seconds, then the X-axis and Y-axis resolutions 
will be shown. 

-

For example, '

X=1:00'00"

'  implies that the resolution of 

X-axis is 1 hour per column; at the same time, '

Y=0.5mb

implies that the resolution of Y-axis is 0.5  millibar per 
row.

-

T h e   h i g h e s t   a n d   t h e   l o w e s t  a l t i t u d e s   o f   t h e   H i s t o r y  
Graph will be shown on the display a while later .

-

F o r   e x a m p l e ,   '

H I G H E S T   1 1 0 0 . 0 m b

'   i m p l i e s   t h a t   t h e  

current maximum pressure of the Pressure History Graph 
is 1100.0 millibar. '

LOWEST 1000.0m

' implies that the 

m i n i m u m   p r e s s u r e   o f   t h e   P r e s su r e   H i s t o r y   G r a p h   i s  

1000.0

 millibar.

NOTE:

-

T h e   r e s o l u t i o n   o f   X - a x i s   o f  t h e   h i s t o r y   g r a p h   ( t i m e  
variable) is fixed as 1 hour.

-

The resolution of Y-axis of the history graph ( barometric 
pressure variable) is ranging from 0.1, 0.2, 0.5, 1, 2, 5, 
10, 20, 50, 100, 200 and 300 millibar.

Pressure 
Graph Display

lap/reset

button

History Graph Scale Display

Barometric Pressure 

History Graph

the pressure 
variable
(Y-axis)

the time variable
(X-axis)

pressure

total display time 
(1 hour X 40 column=40 hour)

total display pressure
(Y axis resolution X 11 row)

Y-axis

resolution

0.1, 0.2, 0.5

1, 2, 5 

10, 20, 50

100, 200, 300

millibar(s)

X-axis

resolution

1 hour

48 Hour Memory Display

Barometric Calibration Sequence

Barometric Graph Display

adjust
button

mode

button

hold 

adjust

mode

button

To view  the memory

by forward scrolling
(from -48 to -1 

)

hour

To view the memory 

by backward scrolling

(from -1 to -48 hour)

start/stop

start/stop

lap/reset

lap/reset

Increment the 
Barometric Pressure

Decrement the 
Barometric Pressure

flashing

digits

6.0 Barometer Mode and its sub-displays

28

29

30

31

60

15

30

45

60

15

30

45

Содержание K2-100

Страница 1: ...ale 5 3 Altimeter Mode Calibrate the Altimeter 5 4 Altimeter Mode Set the Altitude Alarm 5 5 Altimeter Mode Normal Altitude and Relative Altitude 1 2 3 4 5 6 7 8 9 10 11 12 13 14 16 17 18 19 20 5 6 Al...

Страница 2: ...r K2 100 in a dry place when it is not in use 1 0 Introduction 1 3 2 4 2 0 The K2 100 Parts and Its Functions 3 0 Major Function Modes Time Keeping Altimeter and Barometer Mode Time Keeping Mode mode...

Страница 3: ...art stop button to increase the number Press the lap reset button to decrease the number 15 gives a darker display 0 gives a lighter display After you set the time date display format and display cont...

Страница 4: ...e lap number will be displayed at the right hand side of the display for 5 seconds as well as the lap time display on the bottom row of the display Then the chronograph starts running again automatica...

Страница 5: ...ress the mode button to exit the setting sequence If no bu tton is pressed in the setting display for about 3 minutes the K2 100 will return to the Timer Mode automatically hour second minute Timer Co...

Страница 6: ...meter Graph Display In the Altimeter Graph Display the 1st row of the display shows the altitude history graph of the last 24 hours T h e 2 n d r o w o f t h e d i s p l a y s h o w s t h e a l t i t...

Страница 7: ...istory graph are recorded early than those on the right The flashing column of the history graph indicates which memory is displaying during the 24 hour memory reviewing 5 5 Altimeter Mode Normal Alti...

Страница 8: ...M indicator starts flashing which indicates that the User Log Memory recording in progress Press the start stop button once again to stop the recording of the User Log Memory Free Record Display While...

Страница 9: ...ld lap reset lap reset button Graph Scale Display 6 0 Barometer and its sub displays continue Barometric Graph Display 31 32 6 2 Barometer Mode Pressure History Graph Scale Pressure History Graph Scal...

Страница 10: ...ory graph shows on the 1st row of the display T h e p r e s s u r e m e m o r y a n d te m p e r a t u r e s h o w o n the 2nd row of the display The time which recorded the memory shows on the 3rd ro...

Страница 11: ...econds Measuring Mode 10 lap memories Recall lap memories and total time 7 0 Specifications Altitude Reference Setting 9164m to 9164m or 30065ft to 30065ft Influence Minimum influence of temperature c...

Отзывы: