La Crosse Technology K2-100 Скачать руководство пользователя страница 7

GB

GB

GB

GB

adjust
button

flashing

column

ascending or 

descending rate

flashing

column

24 Hour Memory Display
( the newest memory)

24 Hour Memory Display
(the oldest memory)

hold

adjust

adjust
button

lap/reset

button

lap/reset

button

adjust
button

adjust
button

adjust
button

hold

adjust

Relative Altitude Setting Sequence

Relative Altitude Display

Normal Altitude Display

mode

button twice

To view  the memory

by forward scrolling

(from -24 hour to -15 min.

To view the memory 

by backward scrolling

(from -15 min. to -24 hour)

24

Altitude Graph Display

adjust
button

Ascending / Descending 

Rate Display

5.7 Altimeter Mode 

- Ascending and Descending Rate of the 24 Hour Memory

 

lap/reset

To view  the memory

by forward scrolling

(from -24 hour to -15 min.)

To view the memory 

by backward scrolling

(from -15 min. to -24 hour)

mode

button

adjust
button

adjust
button

start/stop

22

23

5.6 Altimeter Mode 

- 24 Hour Memory (the History Graph)

 

21

Normal and Relative Altitude

-  T h e  

K 2 - 1 0 0  

m e a s u r e s   N o r m a l   a n d   R e l a t i v e  

Altitudes.

-

Normal altitude is the difference between your current 
altitude and  SEA LEVEL. (Assuming that air pressure at 
sea level is 1013.21mbar).

-

R e l a t i v e   a l t i t u d e   i s   t h e   d i f f e r e n c e   b e t w e e n  

  y o u r  

current altitude and the altitude of a specific altitude level 
at which you set the  altimeter to 'Zero'. 

-

T o   u s e   r e l a t i v e  a l t i t u d e ,   f o r   e x a m p l e ,   m e a s u r e  t h e  
altitude difference between the starting point and the 
finish

 points of a trek. 

- To measure the altitude difference, set the 

K2-100

 to 

Relative Altitude display at the starting point of the trek, 
the 

K2-100

 will automatically set the altitude to 'Zero'.  

-

Check the altitude at the finish point of the trek, the 

K 2 - 1 0 0  

w i l l   s h o w   t h e   a l t i t u d e   d i f f e r e n c e   o n   t h e

display.

To Switch between the Normal and Relative Altitude

-

Press and hold the [adjust] button for 2 seconds to enter 
Altitude Setting Display. Press the [adjust] button four 
times to select the Normal / Relative Altitude Display.

-

Press and hold the [adjust] button to enter the setting 
display of the Normal / Relative Altitude Display. Press 
the [lap/reset] button to switch between the Normal  and 
Relative Altitude. 

-

After you set the altitude, press the [mode] button to 
exit the setting sequence. Press the [mode] button once 
again to return to the Altitude Graph Display.

24 Hour Memory

- The 

K2-100

 has two altitude memory functions: the 24  

Hour Memory and the User Log Memory.

-

24 Hour Memory automatically records the altitude  values 
for every 15 minutes of  the last 24 hours. 

-  T h e s e   f i g u r e s   c a n   b e   r e v i e w e d   i n     t h e   2 4   H o u r  

Memory Display.

Review the 24 Hour Memory

-

Press the [adjust] button to select the 24 Hour Memory 
Display, in the Altitude Graph Display.

-

The '

ALTIMETER 24 HR MEM

' will slide out and display 

for 3 seconds, the '

MEM

' indicator will be 

shown as

well

.

-

The Altitude 24 hour's hist ory graph shows on the 1st row 
of the display.

-

The altitude memory and temperature shows on the 2nd 
row of the display.

- The time 

that the

 memory was recorded 

will 

show on 

the 3rd row of the display.

-

Press the [lap/reset] button to view the memory through 
backward scrolling (from -15min  to -24hour), press the 
[start/stop] button to view the  memory through forward 
scrolling (from -24 hour to -15 min).

Note: 

-

T h e   m e m o r y   c o l u m n s   o n   t h e  l e f t   h a n d   s i d e   o f   t h e 
history graph are recorded early than those on the right.

-

The flashing column of the history graph indicates which 
m e m o r y   i s   d i s p l a y i n g   d u r i n g   t h e  2 4   h o u r   m e m o r y  
reviewing.

5.5 Altimeter Mode 

- Normal Altitude and Relative Altitude

 

Altitude Graph Display

Altitude Graph Display

start/stop

lap/reset

lap/reset

button

mode

button

5.8 Altimeter Mode 

- The User Log Memory (ULM)

 

User Log Memory

- The 

K2-100

 

has a 

built-in altitude memory function - User

Log Memory (ULM). 

-

The user can set the starting/finishing time and the 
sampling interval of the ULM. For  example,  start the 
recording of the ULM at  the starting point of a  trek, stop 
the recording of the ULM at the finish point of that trek, 
and set the sampling rate as 30 minutes.

-

Check the 

'To Set Sampling Rate'

 section for setting the 

sampling rate of the ULM.

T h e   A l t i t u d e   L o g b o o k ,   A l t i t u d e   M e m o r y   R e c o r d   a n d  
Altitude Memory Segments

-

T h e   a l t i t u d e   m e m o r y   r e c o r d s  i s   t h e   a l t i t u d e   d a t a   o f 
each sampling during the ULM recording.

-

T h e   a l t i t u d e   m e m o r y   s e g m e n t  i s   a   g r o u p   o f   a l t i t u d e 
memory records of one ULM recording  

.
-

The altimeter logbook stores all altitude memory segments.

The Feature of the User Log Memory

 

- During the review of the ULM segments or records, 

the 

K2-100

 shows the following:

1. The date which the memory segment was recorded,
2. The time span of the memory segment,
3. The time which the altitude record was stored,
4. 

The temperature at which the altitude record was 
stored,

5. The scale of the history graph,
6. The max and min altitudes of the history graph,
7. The ascend/descend rate (the difference bet ween  two  

memory records) of the altitude record,

8. The accumulative ascend (the total ascending) and,
9. The accumulative descend (the total descending) of the 

altitude record.

ULM
Altimeter 
Logbook

starting point
of a trek 
(start recording)

8 March 2001
AM 8:00 00 

The date which the memory segment was recorded: 8 March 2001
The time span of the memory segment: 5:00 00 

8 March 2001
PM 1:00 00 

altitude memory 
record

altitude memory 
segment

0

300

200

100

400

500

600

m

700

30

60

90

120

150

180

210

the sampling rate = 30 minutes

240

270

300 minute

Finish point 
of a trek
(stop recording)

The Relationship between Altimeter Logbook, 

Altitude Memory, Segment and Altitude Memory Record

ULM
Altitude Memory 
Segment

ULM
Altitude Memory 
Record

Ascending and Descending Rate

- The 

K2-100

 

has

 a 

built-in 

function for calculating the ascending 

and descending rate of the Altitude of the last 24 hours. 

-

T h e   a s c e n d i n g   a n d   d e s c e n d i n g   r a te   i s   t h e   a l t i t u d e  
difference between two memory records.

-

A (+) value implies ascending rate; a (-) value implies a 
descending rate.

-

T h e s e   r a t e s   c a n   b e   r e v i e w e d  i n   t h e   A s c e n d i n g /  
Descending Rate Display.

Review the Ascending and Descending Rate

-

P r e s s   t h e   [ a d j u s t ]   b u t t o n  t h r e e   t i m e s   t o   s e l e c t  t h e  
Ascending / Descending Rate Display, in the Altitude 
Graph Display.

-

While the Ascending / Descending Rate Display is shown, 
the Altitude Ascending or Descending Rate shows on the 
1st row of the display.

-

The altitude memory and temperature show on the 2nd 
row of the display.

- The  time 

that the

 memory 

was 

recorded show

s

 on 

the 3rd row of the display.

-

P r e s s   t h e   [ l a p / r e s e t ]   b u t t o n  t o   v i e w   t h e   m e m o r y   b y 
backward scrolling ( from -15 min. to 24 hour), press the 
[start/stop] button to view the  memory through forward 
scrolling (from -24 hour to -15 min.).

While

 these displays are shown,  press the [mode] button 

t o   e x i t   t h e   r e v i e w i n g   a n d  t h e   d i s p l a y  

w i l l  

r e t u r n  

to the 

Altitude Graph Display.

20

21

22

23

Содержание K2-100

Страница 1: ...ale 5 3 Altimeter Mode Calibrate the Altimeter 5 4 Altimeter Mode Set the Altitude Alarm 5 5 Altimeter Mode Normal Altitude and Relative Altitude 1 2 3 4 5 6 7 8 9 10 11 12 13 14 16 17 18 19 20 5 6 Al...

Страница 2: ...r K2 100 in a dry place when it is not in use 1 0 Introduction 1 3 2 4 2 0 The K2 100 Parts and Its Functions 3 0 Major Function Modes Time Keeping Altimeter and Barometer Mode Time Keeping Mode mode...

Страница 3: ...art stop button to increase the number Press the lap reset button to decrease the number 15 gives a darker display 0 gives a lighter display After you set the time date display format and display cont...

Страница 4: ...e lap number will be displayed at the right hand side of the display for 5 seconds as well as the lap time display on the bottom row of the display Then the chronograph starts running again automatica...

Страница 5: ...ress the mode button to exit the setting sequence If no bu tton is pressed in the setting display for about 3 minutes the K2 100 will return to the Timer Mode automatically hour second minute Timer Co...

Страница 6: ...meter Graph Display In the Altimeter Graph Display the 1st row of the display shows the altitude history graph of the last 24 hours T h e 2 n d r o w o f t h e d i s p l a y s h o w s t h e a l t i t...

Страница 7: ...istory graph are recorded early than those on the right The flashing column of the history graph indicates which memory is displaying during the 24 hour memory reviewing 5 5 Altimeter Mode Normal Alti...

Страница 8: ...M indicator starts flashing which indicates that the User Log Memory recording in progress Press the start stop button once again to stop the recording of the User Log Memory Free Record Display While...

Страница 9: ...ld lap reset lap reset button Graph Scale Display 6 0 Barometer and its sub displays continue Barometric Graph Display 31 32 6 2 Barometer Mode Pressure History Graph Scale Pressure History Graph Scal...

Страница 10: ...ory graph shows on the 1st row of the display T h e p r e s s u r e m e m o r y a n d te m p e r a t u r e s h o w o n the 2nd row of the display The time which recorded the memory shows on the 3rd ro...

Страница 11: ...econds Measuring Mode 10 lap memories Recall lap memories and total time 7 0 Specifications Altitude Reference Setting 9164m to 9164m or 30065ft to 30065ft Influence Minimum influence of temperature c...

Отзывы: