La Crosse Technology D013.105.M3 Скачать руководство пользователя страница 2

PREPARE FORSETUP 

 

1. Begin set up near your existing network router and a 

computer with high-speed Internet access. 

2. Unpack package contents and insert the H2O sensor cord 

into the TX71U-IT water detector (see diagram 1). 

 

SETUP AND ACTIVATION 

 

1.  Locate the 

Activation Key Card

 in the package for setup 

instructions and the 

Activation Key

. The Activation Key is 

necessary to activate your sensor with Internet Gateway 
(sold separately). Keep your Activation Card for reference.  

2.  Visit 

www.lacrossealerts.com

 with your Activation Key 

Card to create your account and activate the product. 

 
 
 

ACTIVATION INFORMATION:  

THE INCLUDED

 

ACTIVATION KEY

 is good for  

3 Months of

 

ENHANCED SERVICE

 with early warning 

text & e-mail alerts, 

plus 4 more years of

 

BASIC 

SERVICE

 for standard remote monitoring. 

 

Lost your Activation Key Card? 

 
Contact Customer Support: 
www.lacrossetechnology.com/support/alerts 
Phone: (608) 785-7920 

 
 
 

MEASUREMENT LOG DOWNLOAD 

 
Once the sensor is activated and building a measurement log, 
you can download the data as a comma separated values 
(CSV) file. You must use an application such as Microsoft 
Excel® or Google Docs® that supports comma separated 
values (CSV) formatted files to view the table data. 
 

SELECT A LOCATION TO MOUNT WATER DETECTOR 

 

  Select a location protected from water and other 

precipitation. The case is water resistant, not water proof. 

  Place the sensor in a dry, shaded area. Avoid locations with 

direct sun, to prevent inaccurate readings. 

  Fog and mist will not harm the sensor but direct precipitation 

must be avoided.  

 

Note:

 Exposing the sensor case to extreme humidity may 

temporarily disrupt data. The water detector with LCD should 
not be submerged in water.  

  Attach the H20 cable sensor to the Remote Water Detector 

case and place it on the floor for water monitoring. Secure 
the Remote Water Detector case in an area that is protected 
from water. Once activated, the H2O/Dry readings will 
display on the LCD. 

  The H20 sensor on 6 ft. cable is not for use in a pool or hot 

tub where chemicals may cause malfunction. 

  Select a location within range of the Internet Gateway  

(see 

IMPORTANT SETUP & OPERATION NOTES”). 

 
 
 

CONFIRM CONNECTION BEFORE MOUNTING 

 

 

IMPORTANT:

 Before permanently mounting…

Test sensor 

in the desired mounting location for at least 1 hour

 to 

confirm good reception. Confirm consistent readings on your 
account at 

www.lacrossealerts.com

 before permanently 

mounting. 

Move the sensor closer to the Internet 

Gateway if the signal is lost or not received.

 

 

Mount the sensor after the activation process  

(see “SETUP AND ACTIVATION”). 

 

MOUNT TO WALL WITH SCREWS 

 
1.  Remove the mounting bracket  
2.  Place bracket over the desired 

location.  

3.  Mark mounting surface with a pencil 

through the 2 holes of the bracket. 

4.  Screw bracket onto surface and  

tighten screws to bracket. 

5.  Insert the sensor back into the bracket. 

 

FREE STANDING 

 
Attach the mounting bracket to the bottom or  
top of the sensor and place it on any flat surface.

 

 
 

PLACEMENT OF THE H2O SENSOR 

 
The H2O sensor should be placed on the dry floor or against 
the wall near your foundation, water heater, sump, plumbing, 
washer aquarium, or dish washer etc. to monitor for leaks. 
 

FLOOR:  

Place the H2O sensor (circuit board down) on 
the dry floor within range of the remote water 
detector case that is mounted on the wall or 
standing on a table. 

Note

: The water detector 

will sit 1/8 inch from the floor in this position. 
 

WALL:  

Place the H2O sensor against the wall with the 
edge touching the floor within range of the 
remote water detector case that is mounted on 
the wall or standing on a table. 
 

  The H2O sensor can be secured to the floor or wall with the 

included screws & anchors or with two-sided tape (not 
included). 

  Secure the 6 ft. H2O sensor cable to avoid tripping hazards: 

Loosely coil and secure the extra cable with a twist tie. 
 

CLEANING THE H2O SENSOR 

 
Routine cleaning of the H2O sensor 
is recommended to ensure proper 
operation. 
 

 

Use clean water and a soft cloth to clean dirt and debris from 
the circuit board of the H2O sensor. 

Note

: When using two-

sided tape, replace the tape after cleaning the H2O sensor to 
maintain adhesiveness.  

Содержание D013.105.M3

Страница 1: ...ects WET H20 or DRY DRY conditions 3 Screws and drywall anchors PRINTED MATERIALS CONTENTS 4 Printed Product Overview Guide this document IMPORTANT Product set up and activation instructions are online www lacrossealerts com 5 IMPORTANT Activation Key Card required for set up and activation Do not throw away ADDITIONAL EQUIPMENT NOT INCLUDED Two fresh AAA IEC LR03 1 5V Alkaline batteries Two sided...

Страница 2: ...t cable is not for use in a pool or hot tub where chemicals may cause malfunction Select a location within range of the Internet Gateway see IMPORTANT SETUP OPERATION NOTES CONFIRM CONNECTION BEFORE MOUNTING IMPORTANT Before permanently mounting Test sensor in the desired mounting location for at least 1 hour to confirm good reception Confirm consistent readings on your account at www lacrossealer...

Страница 3: ...La Crosse Technology Ltd provides a 1 year limited warranty on this product against manufacturing defects in materials and workmanship This limited warranty begins on the original date of purchase is valid only on products purchased and used in North America and only to the original purchaser of this product To receive warranty service the purchaser must contact La Crosse Technology Ltd for proble...

Страница 4: ... may charge users for alert services Standard messaging and data rates apply and will be billed to the customer s wireless account Customers may be unable to receive text messaging or data service in some areas due to unavailability of service 2 La Crosse shall not be liable for accuracy usefulness or availability of data transmitted via the service Users are solely responsible for damages to pers...

Отзывы: