background image

La Crosse Technology, Ltd.            www.lacrossetechnology.com/support 

Page 13 

 

 

Batteries

 may be overpowered or underpowered. Remove batteries from alarm clock.  

 

Press any button 20 times. Leave the alarm clock unpowered for 1-2 hours.  

 

Power clock with AC adapter only to determine if batteries were an issue.  

 

 Weather station has missing segments 

 

Explanation: When parts of numbers, letters, or pictures are missing on the display, it is 

often power related.  

 

Check that the AC adapter. Is it correctly installed and connects to an active outlet. 

 

Batteries

 may be overpowered or underpowered. Remove batteries from alarm clock.  

 

Press any button 20 times. Leave the alarm clock unpowered for 1-2 hours.  

 

Power clock with AC adapter only to determine if batteries were an issue.  

 

Содержание C87214

Страница 1: ...ding 4 Intermittent Outdoor Temperature 4 Outdoor Temperature is stuck or HH H LL L 4 Outdoor sensor drains batteries quickly 5 Outdoor Humidity goes to dashes when temperature is cold 5 Outdoor senso...

Страница 2: ...t least six years in advance of the current year Batteries dated earlier than six years from now may still work but may be unstable in performance Good name brand batteries make less noise which reduc...

Страница 3: ...2 minutes for the outdoor temperature to appear on the weather station Factory Restart If the above procedure does not work please try the factory reset Outdoor Temperature Signal Strength Explanatio...

Страница 4: ...come and go occasionally This can be normal in some environments e g moister climates If outdoor sensor signal is lost please wait 2 4 hours for the signal to reconnect on its own Move the outdoor sen...

Страница 5: ...l damage to the outdoor sensor the fall may not have caused internal damage A fall can shock the outdoor sensor or the batteries in the outdoor sensor Batteries that have fallen on a hard surface may...

Страница 6: ...the button for five seconds to reset HI temperature and humidity values for indoor and outdoor data View LO data Press the button once to view LO temperature and humidity values for indoor or outdoor...

Страница 7: ...ast station to stay 5 10 feet apart for 15 minutes to establish a solid connection Install the battery covers on each sensor After 15 minutes place the remote transmitters in appropriate locations wit...

Страница 8: ...hin a wall This will interfere with RF radio frequency signal reception Distance Resistance Interference Distance The transmitting range in open air is over 300 feet 91 meters between the outdoor sens...

Страница 9: ...and release the buttons to select ON If disarmed OFF skip the alert value and move to next alert 4 Press and release ALERTS button and alarm value will flash 2 Press and release the buttons to adjust...

Страница 10: ...ain to turn the backlight off Press and release the HI LOW OFF button to return to full strength Note When the backlight is off press any button to activate the backlight for 10 seconds Battery power...

Страница 11: ...nooze the alarm for 10 minutes The snooze option can repeat three times The alarm icon will flash while the snooze feature is active Note while the alarm sounds press any button except the ALARM butto...

Страница 12: ...inform you when the humidity is at a comfortable or uncomfortable level The bar over the chart will move and change colors to indicate the humidity level Forecast Icons Inaccurate THIS WEATHER STATION...

Страница 13: ...eries were an issue Weather station has missing segments Explanation When parts of numbers letters or pictures are missing on the display it is often power related Check that the AC adapter Is it corr...

Отзывы: