Manually Set Time/Date:  Program Menu

 .................................................................................10 

Temperature station is dim

 .....................................................................................................11 

Temperature station has distorted or frozen display

 ................................................................11 

Temperature station is blank: No letters, numbers or dashed lines

 ...........................................12 

Temperature station drains batteries quickly

 ...........................................................................12 

Temperature station has missing segments

 .............................................................................12 

 

Batteries 

 

Explanation: Many problems are resolved with fresh batteries of the appropriate voltage. 

Many items sent in under warranty work when tested with fresh batteries. Batteries 

manufactured this year will have an expiration date 10 years (or more) in the future. Battery 

technology has improved and batteries will maintain voltage longer in storage. However, 

the environment the batteries reside in for the 10 years can deplete the power. 

 

 

We suggest name brand Alkaline batteries for indoor displays.  

 

Use Alkaline or Lithium batteries in the outdoor sensors. 

 

A minimum voltage of 1.48V for each battery is necessary for proper performance.   

 

Use batteries dated at least six years in advance of the current year. Batteries dated 

earlier than six years from now may still work, but may be unstable in performance.   

 

Good name brand batteries make less noise, which reduces the chance of RF (radio 

frequency) interference from the battery compartment.  

 

  Temperature Station Factory Restart 

 

Explanation: The factory restart returns the temperature station and outdoor sensor to an 

“out-of-the-box” state and often resolves an issue.  

  

Factory Restart: 

1.

 

Remove all power from outdoor sensor and temperature station.  

2.

 

Press one of the buttons on the temperature station at least 20 times to clear all 

memory.  

3.

 

Verify that the temperature station is blank before proceeding (there are some painted 

lines that will not disappear). 

4.

 

Leave batteries out of both units for 15 minutes (very important). 

5.

 

Insert fresh Alkaline batteries into the temperature station.  

6.

 

Insert fresh batteries into the outdoor sensor. 

7.

 

Press the TX button on the outdoor sensor to transmit RF signal.   

8.

 

Keep the outdoor sensor 5-10 feet from the temperature station. 

9.

 

When RF connection is established, the temperature will appear on the station. Allow 

the outdoor sensor and temperature station to sit together for 15 minutes to establish a 

strong connection.  

10.

 

Do not press buttons for 15 minutes. 

 

 

For optimum 433MHz transmission, place the outdoor sensor no more than 300 

feet (91 meters, open air) from the temperature station. 

Содержание 308-179ORV2

Страница 1: ...ments 4 Inaccurate Outdoor Temperature Reading 4 Intermittent Outdoor Temperature 4 Outdoor Temperature is stuck or HH H LL L 5 Outdoor sensor drains batteries quickly 5 Outdoor sensor fell The sensor...

Страница 2: ...till work but may be unstable in performance Good name brand batteries make less noise which reduces the chance of RF radio frequency interference from the battery compartment Temperature Station Fact...

Страница 3: ...perature station Factory Restart If the above procedure does not work please try the factory reset Outdoor Temperature Signal Strength If sensor loses connection to the weather station for any reason...

Страница 4: ...tly when next to the temperature station try a different location outside Intermittent Outdoor Temperature Explanation Intermittent problems are the hardest to resolve RF radio frequency communication...

Страница 5: ...rk while batteries are fresh but not after they drain a bit Check for leaking batteries which may damage the outdoor sensor Battery life is over 24 months when using reputable battery brands for both...

Страница 6: ...y HI Indoor humidity LO Mounting Positioning Outdoor sensor First Place the outdoor sensor in the desired shaded location and the temperature station in the home Wait approximately 1 hour before perma...

Страница 7: ...large metal objects can reduce the range Choose a location 6 feet or more from electronics such as cordless phones wireless gaming systems televisions microwaves routers baby monitors etc which can p...

Страница 8: ...Select Temperature Alert Values 1 Hold the ALERTS button 2s to enter alert set mode LO or HI alert icon and ALERT OFF will show for selected area 2 Press and release the or button to turn alert ON 3...

Страница 9: ...the temperature station unpowered for 1 2 hours Install fresh Alkaline batteries with correct polarity If the indoor temperature is still shows dashes HH H or LL L the temperature station may need re...

Страница 10: ...inactive Snooze Alarm When alarm sounds press the ALARM SNOOZE button to silence alarm for 10 minutes The alarm icon will flash SNZ will show and the remaining Snooze Time will count down Press any bu...

Страница 11: ...s 10 Press SET to confirm and exit Temperature station is dim Explanation Most temperature stations have a gray background Place the temperature station at eye level to determine if it is dim Temperat...

Страница 12: ...e down the date of installation and the voltage of the batteries When the batteries fail please note the date and voltage again This is helpful in determining the problem Check for leaking batteries w...

Отзывы: