background image

22

italiano

francese

inglese

Motore 1000m3/h - Alluminio EUROPA 230V

Débits de moteurs  1000m3/h - 230V

Motor 1000m3/h - Alluminium EUR 230V

Vel.

Portata oraria

Rumorosità Pressione Potenza

Vitesse

Débit

Niveau de Bruit

Pression Puissance

speed

Capacity

Noise level

Pressure

Absorption

1°  

330 m3/h

45 dba

275 Pa

W 90

1°  

330 m3/h

45 dba

275 Pa

W 90

1°  

330 m3/h

45 dba

275 Pa

W 90

2°  

490 m3/h

50 dba

410 Pa

W 145

2°  

490 m3/h

50 dba

410 Pa

W 145

2°  

490 m3/h

50 dba

410 Pa

W 145

3°  

730 m3/h

56 dba

440 Pa

W 250

3°  

730 m3/h

56 dba

440 Pa

W 250

3°  

730 m3/h

56 dba

440 Pa

W 250

4°  

1.000 m3/h

63 dba

480 Pa

W 265

4°  

1.000 m3/h

63 dba

480 Pa

W 265

4°  

1.000 m3/h

63 dba

480 Pa

W 265

3 X Lampada dicroica 20W

3 X  halogènes  20W

3 X lamp 20W

2 X filtro antigrasso 415mmX350mmX25mm

2 X filtres   415mmX350mmX25mm

2 X filter  415mmX350mmX25mm

Diametro tubo uscita aria 150mm

Diamètre de collerette de sortie mm 150

Air outlet 150mm

Motore 600cfm - Alluminio USA 120V

Débits de moteurs   600cfm  USA 120V

Motor 600cfm - Alluminium USA 120V

Vel.

Portata oraria

Rumorosità Pressione Potenza

Vitesse

Débit

Niveau de Bruit

Pression Puissance

speed

Capacity

Noise level

Pressure

Absorption

1°  

330 m3/h

41 dba

280 Pa

W 120

1°  

330 m3/h

41 dba

280 Pa

W 120

1°  

330 m3/h

41 dba

280 Pa

W 120

2°  

490 m3/h

50 dba

470 Pa

W 175

2°  

490 m3/h

50 dba

470 Pa

W 175

2°  

490 m3/h

50 dba

470 Pa

W 175

3°  

730 m3/h

56 dba

500 Pa

W 280

3°  

730 m3/h

56 dba

500 Pa

W 280

3°  

730 m3/h

56 dba

500 Pa

W 280

4°  

1000 m3/h

63 dba

620 Pa

W 320

4°  

1000 m3/h

63 dba

620 Pa

W 320

4°  

1000 m3/h

63 dba

620 Pa

W 320

3 X Lampada dicroica 20W

3 X  halogènes  20W

3 X lamp 20W

2 X filtro antigrasso 415mmX350mmX25mm

2 X filtres   415mmX350mmX25mm

2 X filter  415mmX350mmX25mm

Diametro tubo uscita aria 150mm

Diamètre de collerette de sortie mm 150

Air outlet 150mm

Содержание H1LP

Страница 1: ...NSTALLATION L EMPLOI ET L ENTRETIEN DE LA HOTTE CornuF EN INSTALLATION USE AND MAINTENANCE OF HOOD CornuF IT ISTRUZIONE PER L INSTALLAZIONE L USO E LA MANUTENZIONE DEL PRODOTTO CornuF DE BEDIENUNGSANL...

Страница 2: ...2 REFERENCES IN THE TECHNICAL DATA PLATE For CE MARKET Family FSEB ED Model S84 E Equipment BC84 E A B 7I3 For CSA MARKET Family FSUA Model SU84 Equipment I3 A B 7I3...

Страница 3: ...Uses Dimensions and technical sketch of the product Conformity to the European directives on the Recycling Of Electrical And Electronic Equipment Electrical diagram Installation Working Maintenance C...

Страница 4: ...ate ventilation of the room when the range hood is used at the same time as appliances burning gas or other fuels not applicable to appliances that only discharge the air back into the room Air captur...

Страница 5: ...gative pressure in the room which can t exceed the limit of 0 04 mbar in order to avoid the suck of exhausts deriving from the heat source Therefore the room should be provided with air intakes to all...

Страница 6: ...Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA and the American So ciety for Heating Refrigeration...

Страница 7: ...extinguisher and you already know how operate it 2 The fire is small and contained in the area where it started 3 The fire department is being called 4 You can fight the fire with your back to an exit...

Страница 8: ...21 DIMENSIONS AND TECHNICAL SKETCH OF THE HOOD...

Страница 9: ...Pa W 250 W 265 4 1 000 m3 h 63 dba 480 Pa W 265 3 X lamp 20W 2 X filter 415mmX350mmX25mm Air outlet 150mm Motor 600cfm Alluminium USA 120V Puissance speed Capacity Noise level Pressure Absorption W 12...

Страница 10: ...with directives and standards Range hoods manufactured for USA and Canada are cCSAus certified according to standard requirements CONFORMITY TO THE EUROPEANDIRECTIVES ON THE RE CYCLING OF ELECTRICAL...

Страница 11: ...c screws to complete the installation insert the two fixing screws in the rear of the cooker hoods in the 2 holes previously made Before fixing the chimneys connect the power supply behind the decorat...

Страница 12: ...th rate level switch F 10 minute timer remote control for the command to distance of cooker hoods TECHNICAL DATA Alkaline battery powered 12V Mod 23A Operating frequency433 92Mhz Combinations 4096 con...

Страница 13: ...cribed below press si multaneously buttons for 2 seconds When Leds light on press but tons RC001 RADIO CONTROL Radio control used for the remote operation of ducted cooker hoods TECHNICAL DATA Alkalin...

Страница 14: ...cifications set out in the Directive RED 2014 53 EU WARNING Any adjustments or modifications which have not been expressly approved by the holder of the legal conformity certificate may invalidate the...

Страница 15: ...buttons Press the timer button to reset The grease filter needs cleaning by regular hand washing or in dishwashers every two months at least or depending on its use To clean the appliance itself tepid...

Страница 16: ...owever a hand crafted enamel surface is never completely even and slight variations in shade may occur This is a guarantee of quality and is linked to the nature of our enamelling process This warrant...

Страница 17: ...82 Fig 1 Fig 2 Fig 3 Fig 4 Fig 5 Fig 6...

Страница 18: ...Fig 7 Fig 8 Fig 9 Fig 10 83...

Страница 19: ...nt Z I les B thunes 95310 Saint Ouen l Aum ne FRANCE Adresse postale La Cornue SAS B P 99006 95070 Cergy Pontoise Cedex FRANCE T l 33 0 1 34 48 36 36 Fax 33 0 1 34 64 32 65 E mail a table la cornue co...

Отзывы: