24
INSTALLATION
Check the appliance is electrically safe when you have finished.
Electrical Connection
The cooker must be installed by a qualified electrician, in
accordance with all relevant British Standards/Codes of
Practice (in particular BS 7671), or with the relevant national
and local regulations.
Current Operated Earth Leakage Breakers
The combined use of your cooker and other domestic
appliances may cause nuisance tripping, so we
recommend that the cooker is protected on an individual
RCD (Residual Current Device) or RCBO (Residual Current
Breaker with Overload).
IF IN DOUBT, PLEASE CONSULT A SUITABLY
QUALIFIED ELECTRICIAN.
n
n
WARNING: THE APPLIANCE MUST BE EARTHED.
Note:
The cooker must be connected to the correct electrical
supply as stated on the voltage label on the cooker, through
a suitable cooker control unit incorporating a double-pole
switch, having a contact separation of at least 3 mm in all
poles.
n
n
The cooker MUST NOT be connected to an ordinary
domestic power point.
Access to the mains terminal is gained by removing the
electrical terminal cover box on the back panel. Connect the
mains cable to the correct terminals for your electrical supply
type (
Fig.7.13
and
Fig.7.14
). Check that the connections are
correctly fitted and that the terminal screws are tight. Secure
the mains cable using the cable clamp.
Final Fitting
Fitting the Handrail
The hand rail is supplied as 2 end pieces with grub screws, 2
plastic friction cups and the rail tube
(Fig.7.15)
.
Hold a friction cup by the tabs on one end of the tube. Fit one
of the end pieces to the tube and push it on the tube over the
friction cup
(Fig.7.16)
.
Turn the tube over and fit the other end piece using the
second friction cup, making sure that you do not scratch or
damage the first end piece and the that the two end pieces
are lined up correctly. Fit the assembled hand rail to the
projecting mounting studs on the control panel and fix it in
place by tightening the grub screws. The grub screws should
be on the underside
(Fig.7.17)
.
ArtNo.130-0010 Electrical connections single-phase
L
N
230 V ac 50 Hz
10 mm² max
6 mm² max
L1
N
L3
L2
3N ac
230/400 V 50 Hz
6 mm² max
10 mm² max
6 mm² max
Viewed from above
Fig.7.13
Fig.7.14
Fig.7.15
Fig.7.16
Fig.7.17