COMPONENT MAINTENANCE MANUAL
AVIATION PRODUCTS
Model FA5000
Fits and Clearances
23–70–30
Use or disclosure of information on this sheet is subject to
the restrictions on the cover page of this document.
Rev. 02 Page 804
July 21/17
Table 801. Model FA5000 Environmental Characteristics
The Model FA5000 recorders will be tested to DO
−
160F categories listed below.
DO-160F Section
DO-160F
Section
Number
DO-160F
Category Compliance
(Not
including RIPS battery)
Temperature and Altitude
4
D2/F3
Temperature Variation
5
A
Humidity
6
B
Shock
7
B
Vibration
8
R Curve E & E1/H Curve P
Explosion Atmosphere
9
E, H Env II
Water Proofness
10
Y/W
Fluid Susceptibility
11
F
Sand and Dust
12
D
Fungus Resistance
13
F
Salt Fog
14
S
Magnetic Effect
15
A
Power Input
16
DC: ZXX;
Voltage Spike
17
A
Conducted Susceptibility
18
DC: Z
Induced Signal Susceptibility
19
ZC
RF Radiated and Conducted
Susceptibility
20
RR
RF Radiated and Conducted
Emissions
21
H , L
Lightning Induced Transient
Susceptibility
22
A3J44
Lightning Direct Effects
23
X
Icing
24
A
Electro Static Discharge
(ESD)
25
A
Fire, Flammability
26
B
The document reference is online, please check the correspondence between the online documentation and the printed version.