COMPONENT MAINTENANCE MANUAL
AVIATION RECORDERS
FA2100CVR
Rev. 15 Page 154
Apr. 14/16
Testing & Fault Isolation
23–70–04
Use or disclosure of information on this sheet is subject
to the restrictions on the cover page of this document.
Observe
Figure 160. CATS, Connecting Pop-Up
(g)
From the menu bar, select Power ==> Recorder Interface Reset.
NOTE:
This will load the Altera chip in the RIU unit. Observe the “con-
necting to the recorder” status window appears.
(h)
On the tool bar, select Power.
Figure 161. CATS, Power Toggle
NOTE:
When AC power is applied verify the appropriate LED is lit up on
the RIU.
(i)
Click on the Information tab in the test section of the menu.
The document reference is online, please check the correspondence between the online documentation and the printed version.