l-com L-EL9000 Скачать руководство пользователя страница 15

Hardened Media Converter 

15

 

Specifications

 

Applicable Standards 

IEEE 802.3ab 1000Base-T 

IEEE 802.3z 1000Base-SX/LX 

Fixed Ports 

1 copper port, 1 fiber port  

2000Mbps for full-duplex 

Speed 1000Base-T 

 1000Base-SX/LX 

 

2000Mbps for full-duplex  

Forwarding rate 

1,488,000pps for 1000Mbps 

4-pair UTP/STP Cat. 5 up to 100m 

Cable 1000Base-T 

   1000Base-SX/LX  MMF (50 or 62.5µm), SMF (9 or 10µm) 

Per Unit- (3 LEDs): PWR1, PWR2, FAULT 

LED Indicators 

Per Port- Copper (3 LEDs): LNKC, TX, RX 

Fiber (3 LEDs): LNKF, TX, RX 

Dimensions 

50mm (W) × 110mm (D) x 135mm (H) 

(1.97” (W) x 4.33” (D) x 5.31” (H)) 

Weight 0.8Kg 

(1.76lbs.) 

Power 

DC Jack: 12VDC, External AC/DC required 
Terminal Block: 10-48VDC 

Operating Voltage & Max. 
Current Consumption 

0.76A @ 12VDC, 0.38A @ 24VDC, 0.19A @ 
48VDC 

Power Consumption 

9.12W Max. 

Operating Temperature 

-40°C ~ 75°C (-40

 ~ 167

Tested for functional operation @ 
-40°C ~ 85°C (-40

 ~ 185

UL1604 Industrial Control Equipment certified 
Maximum Surrounding Air Temperature @ 74

 

(165

Storage Temperature 

-40°C ~ 85°C (-40

 ~ 185

Humidity 

5 ~ 95%, non-condensing 

Safety 

Hazardous locations: Class I, Division 2 
group A, B, C & D 

UL60950-1, EN60950-1, IEC60950-1 

EMI 

FCC Part 15, Class A 
EN61000-6-3: EN55022, EN61000-3-2, 
EN61000-3-3 

EMS 

EN61000-6-2: 
EN61000-4-2 (ESD Standard) 
EN61000-4-3 (Radiated RFI Standards) 
EN61000-4-4 (Burst Standards) 
EN61000-4-5 (Surge Standards) 
EN61000-4-6 (Induced RFI Standards) 
EN61000-4-8 (Magnetic Field Standards) 
EN61000-4-11 (Voltage Dips Standards) 

Environmental Test  

Compliance 

IEC60068-2-6 Fc (Vibration Resistance) 
IEC60068-2-27 Ea (Shock) 
IEC60068-2-32 Ed (Free Fall) 

Содержание L-EL9000

Страница 1: ...wo pairs of power inputs can be used to power up this media converter Redundant power supplies function is supported You need to have two power inputs connected to run the media converter but the FAUL...

Страница 2: ...sts the pinouts of 1000Base T port The 1000BaseSX LX Connections The fiber port pinouts The Tx transmit port of device I is connected to the Rx receive port of device II and the Rx receive port of dev...

Страница 3: ...ff Steady A valid network connection established for copper port LNK stands for LINK LNKC Off No valid network connection established for copper port Steady A valid network connection established for...

Страница 4: ...o 75 40 to 167 operating temperature range Tested for functional operation 40 to 85 40 to 185 UL1604 Industrial Control Equipment certified Maximum Surrounding Air Temperature 74 165 y Supports DIN Ra...

Страница 5: ...Hardened Media Converter 5...

Страница 6: ...y Solution The hardened media converter is a plug and play compact media converter which doesn t have any complicated software to set up This manual describes the installation and use of the hardened...

Страница 7: ...TUP AND DISMANTLING 4 Preface 6 Table of Contents 7 Introduction 8 PRODUCT OVERVIEW 8 PRODUCT FEATURES 8 PACKING LIST 9 One Channel Media Converter 10 PORTS 10 PORT SETTINGS 10 DIP SWITCH 10 FRONT PAN...

Страница 8: ...ets IEC61000 6 2 EMC Generic Standard Immunity for industrial environment y Support 802 3ab 802 3z 802 3x Auto negotiation and Auto MDI MDIX y 1000Base SX LX Multi mode Single mode or WDM Single mode...

Страница 9: ...2 Groups A B C and D OR non hazardous locations only y WARNING EXPLOSION HAZARD Do not disconnect equipment unless power has been removed or the area is known to be non hazardous y WARNING EXPLOSION H...

Страница 10: ...ns of a DIP Dual Inline Package switch on the front panel of the hardened media converter Default DIP switch settings 1 2 3 4 1 0 DIP Switch There are four pins on the DIP switch for port settings Ref...

Страница 11: ...stands for POWER PWR1 PWR2 Off Power off Steady A valid network connection established for copper port LNK stands for LINK LNKC Off No valid network connection established for copper port Steady A va...

Страница 12: ...should be less than 95 percent non condensing y Surrounding electrical devices should not exceed the electromagnetic field RFC standards y Make sure that the equipment receives adequate ventilation Do...

Страница 13: ...k Power Inputs There are two pairs of power inputs can be used to power up this device You need to have two power inputs connected to run the media converter but the FAULT LED indicator will light up...

Страница 14: ...that are used for power failure detection It provides a normal closed output when the power source is active Use this as a dry contact application to send a signal for power failure detection Special...

Страница 15: ...Max Current Consumption 0 76A 12VDC 0 38A 24VDC 0 19A 48VDC Power Consumption 9 12W Max Operating Temperature 40 C 75 C 40 167 Tested for functional operation 40 C 85 C 40 185 UL1604 Industrial Contro...

Страница 16: ...Hardened Media Converter 16 NEMA TS1 2 Environmental requirements for traffic control equipment...