manualshive.com logo in svg
background image

2

WARNING

Fire and Explosion Hazard

n

Not for home or recreational vehicle use.

n

Installation of this heater in a home or
recreational vehicle may result in a fire or
explosion.

n

Fire or explosions can cause property
damage or loss of life.

FOR YOUR SAFETY

If you smell gas:
1. Open windows.
2. Don't touch electrical switches.
3. Extinguish any open flame.
4. Immediately call your gas supplier.

FOR YOUR SAFETY

Do not store or use gasoline or other
flammable vapors and liquids in the vicinity of
this or any other appliance.

WARNING

Fire and Explosion Hazard

n

Keep solid combustibles a safe distance
away from the heater.

n

Solid combustibles include wood or paper
products, straw, and dust.

n

Do not use the heater in spaces which
contain or may contain volatile or airborne
combustibles.

n

Volatile or airborne combustibles include
gasoline, solvents, paint thinner, dust
particles or unknown chemicals.

n

Failure to follow these instructions may
result in a fire or explosion.

n

Fire or explosions can lead to property
damage, personal injury or loss of life.

GENERAL  HAZARD  WARNING

n

Failure to comply with the precautions and instructions provided with this heater, can result in:

Death

Serious bodily injury or burns

Property damage or loss from fire or explosion

Asphyxiation due to lack of adequate air supply or carbon monoxide poisoning 

Electrical shock

n

Read this Owner’s Manual before installing or using this heater.

n

Only properly-trained service people should repair or install this heater.

n

Save this Owner’s Manual for future use and reference.

n

Owner’s Manuals and replacement labels are available at no charge.  For assistance, contact
L.B. White at 800-345-7200.

WARNING

n

Proper gas supply pressure must be provided to the inlet of the heater.

n

Refer to dataplate for proper gas supply pressure.

n

Gas pressure in excess of the maximum inlet pressure specified at the heater inlet can cause
fires or explosions.

n

Fires or explosions can lead to serious injury, death, building damage, or loss of plant life.

n

Gas pressure below the minimum inlet pressure specified at the heater inlet may cause
improper combustion.

n

Improper combustion can lead to asphyxiation or carbon monoxide poisoning and therefore
serious injury or death to humans and plant life.

WARNING

CALIFORNIA RESIDENTS

When operating, this heater produces

chemicals, including Carbon Monoxide, known

to the State of California to cause birth defects

and other reproductive harm. For further

information, go to www.P65Warnings.ca.gov.

Содержание Therma Grow 120NG

Страница 1: ...s Manual and Instructions Therma Grow Greenhouse Heaters View this manual online at www lbwhite com 150 27595 REV B ATTENTION ALL USERS This heater has been tested and evaluated by C S A Internationa...

Страница 2: ......

Страница 3: ...s heater can result in Death Serious bodily injury or burns Property damage or loss from fire or explosion Asphyxiation due to lack of adequate air supply or carbon monoxide poisoning Electrical shock...

Страница 4: ...stributor dealer or the L B White Company Contact your local L B White distributor or the L B White Co Inc for assistance or if you have any questions about the use of the equipment or its application...

Страница 5: ...d electrically interlocked with the heater to prevent heater operation if air inlet and exhaust outlet do not open when heating is required Model Indoor Mounting Air Exchange Requirements 1 Burner Man...

Страница 6: ...lding and area before you return Properly trained service people must repair the leak check for further leakages and then relight the appliance for you WARNING n Do not use this heater for heating hum...

Страница 7: ...ipped with a manual reset high limit switch and an air proving switch Never operate this heater with any safety device that has been bypassed Do not operate this heater unless all of these features ar...

Страница 8: ...ground or to a height that would prevent snow blockage of heater s air inlet Refer to instructions provided in the optional L B White outdoor mounting and ducting kit part number 23579 4 The heater mu...

Страница 9: ...appropriate alarms 16 Take time to understand how to operate and maintain the heater by using this Owner s Manual Make sure you know how to shut off the gas supply to the building and also to the indi...

Страница 10: ...MI HD220 HD220 5B ENG BYNAME JIMI HD220 HD220 5B ENG BYNAME JIMI HD220 HD220 5B ENG BYNAME JIMI HD220 HD220 5B ENG BYNAME JIMI HD220 HD220 5B ENG BYNAME JIMI HD220 HD220 5B ENG BYNAME JIMI HD220 HD220...

Страница 11: ...consideration must be given to making sure the heater is located away from the people entering or exiting the greenhouse so they cannot accidentally knock the heater or tamper with the heater and its...

Страница 12: ...NTROL VALVE INLET REGULATORVENT GAS FLOW 1 Always use approved pipe thread compound suitable for use with L P gas or natural gas on the threaded connections 2 Assemble the components together accordin...

Страница 13: ...roximately 17 seconds After igniter warm up time has been achieved the motor will start again and shortly thereafter ignition will occur NOTE It is normal for air to be trapped in the gas hose on new...

Страница 14: ...Periodic cleaning and inspection as well as proper maintenance are essential to avoid serious injury or property damage 1 The area surrounding the heater shall be kept clear and free from combustible...

Страница 15: ...ent jumpered Replace the part immediately An alternate method for checking the components is to perform a continuity check 5 Do not jumper the air proving switch If jumpered the ignition control will...

Страница 16: ...m the switch which indicates the contacts of the switch have opened 4 Allow the switch cool down for about a minute before firmly pressing the red reset button on the switch 5 Check for electrical con...

Страница 17: ...further checking or adjustment is required Proceed to section D 3 If the inlet pressures do not agree with that specified on the dataplate then the regulator controlling gas pressure to the heater req...

Страница 18: ...ocated at the end of the igniter leads See Fig 16 2 Loosen the screw securing the igniter shield and the igniter to the mounting bracket Remove the igniter and shield 3 Ensure the igniter is located s...

Страница 19: ...ition control Red light on ignition control is illuminated Ignition control sends flame sense current to flame sensor Ignition control module performs self safety check Internal components are tested...

Страница 20: ...ace thermostat Is heater connected to power supply No No No Yes Ensure heater is connected to power supply Check breakers Is transformer receiving proper voltage Check wiring for continuity between tr...

Страница 21: ...r proving switch been jumpered Yes No Remove jumper from switch Rapid Flash Reverse polarity Have electrician check neutral and hot wire connections that outlet heater is connected to Long Flash Two s...

Страница 22: ...sary No Is fan wheel plugged with dirt Is there an obstruction in blower outlet preventing air proving switch closure No Are 115 volts sent from ignition control terminal IND to motor relay No If impr...

Страница 23: ...e and component Repair or replace as necessary or replace ignition control Provide proper pressure to heater and check with a gauge Check for voltage to switch Check wiring and repair if defective If...

Страница 24: ...l Flame sense is low and that flame failure or improper operation can occur at any time See flame sensor related problems in three time flash pattern Four Times If HSI board does not reset then replac...

Страница 25: ...24 Electrical Connection and Ladder Diagram 115 Volt Supply 120 VOLT...

Страница 26: ...25 230 Volt Supply 120 VOLT...

Страница 27: ...ation Hot Surface Igniter Ignition device used on automatic ignition control systems Ignites gas by surface temperature rather than spark or flame Ignition Control Module Electronic printed circuit bo...

Страница 28: ...27 28 30 37 38 39 21 20 19 16 17 6 5 7 8 9 10 11 12 4 3 2 1 14 31 32 33 34 35 26 27 29 36 22 25 13 18 15 24 23 Parts Identification PARTS SCHEMATIC...

Страница 29: ...r Igniter Shield 572512 18 Bracket w Screws 570089 19 Flame Sensor 520139 20 High Limit Switch LP Gas 572501 Natural Gas 505566 21 Heat Chamber LP Gas 572499 Natural Gas 572500 22 Control Box w Cover...

Страница 30: ...of the equipment and in any event L B White s liability in connection with the equipment including for claims based on negligence or strict liability is limited to the purchase price Some states do no...