Parts Identification

PARTS LIST

Item

Description

Part N

Number

1

Regulator, LP Gas, 2nd Stage, Vent Over Outlet

06553

Regulator, LP Gas, 2nd Stage, Vent Over Side

06665

Regulator, Natural Gas (5 PSIG Inlet, 13.5 Outlet)

23360

2

Nipple, 3 1/2 in.

07148

3

Valve, Manual Shut Off

05548

4

Hose, 1/2 in. ID x 10 ft. with Adapter

20714

5

Adapter, Hose, 1/2 NPT x 1/2 NPS

02894

6

Kit, Sediment Trap

00815

7

Base

23523

8A

Bracket, Gas Control Valve

21768

8B

Screw, 8-32 x 1/4

09425

9

Valve, Gas Control:  LP Gas

23835

Valve, Gas Control:  Natural Gas

23836

10

Nipple, 1/2 in. x 3 in.

02972

11

Elbow

01426

12

Manifold

09291

13

Orifice, Burner:  LP Gas

23530

Orifice, Burner:  Natural Gas

23531

14

Burner

21724

15

Spacer

02687

16

Igniter and Sensor Assembly

22473

17

Switch, High Limit

05566

18

Chamber, Heat

23566

19

Case, Assembly with Doors and Latches (2)

20465

20

Latch Assembly

20959

21

Harness, Wiring

23534

22

Control, Ignition

22461

23

Transformer, 120/24 v.

81218

24

Cover, Control Box, w/ Hinge & Window Plug

23550

25

Boot, Selector Switch

09916

26

Selector Switch

09915

27

Terminal Strip

22905

28

Cord, Power, 10 ft.

23574

29

O-Ring

08347

30

Plug, Window

08255

31

Motor, 1/3 HP, Ball Bearing

20169

32

Mount, Motor

08647

33

Wheel, Fan

09050

34

Switch, Air Proving

02680

35

Flapper

21035

36

Complete Fan Housing Assembly,

20148

w/ Motor, Fan Wheel, Air Proving Switch, Flapper, and Motor Mount

37

Screw, Burner

02688

38

Washer

01589

39

Bolt

02692

40

Grommet, w/ Hole

21851

(1) Complete control box assembly with all control components is part number 23539.

(2) Specify model number and fuel type when ordering.

(3) Screw part number 07288 (#8 x 3/8) is the standard fastener used for assembly of all sheet metal components.

Содержание FUEL HD120

Страница 1: ...idence in our products and welcome any suggestions or comments you may have call us toll free at 1 800 345 7200 Owner s Manual and Instructions GreenGro Plus Greenhouse Heaters ATTENTION ALL USERS Thi...

Страница 2: ......

Страница 3: ...nal injury or loss of life GENERAL HAZARD WARNING Failure to comply with the precautions and instructions provided with this heater can result in Death Serious bodily injury or burns Property damage o...

Страница 4: ...nce or if you have any questions about the use of the equipment or its application The L B White Co Inc has a policy of continuous product improvement It reserves the right to change specifications an...

Страница 5: ...et and exhaust outlet do not open when heating is required HD120 Propane Natural Gas Gas M Mo od de el l Indoor Mounting Air Exchange Requirements 1 Burner Manifold Pressure In W C Net Weight lbs Ship...

Страница 6: ...ans leading to serious injury or death Symptoms of carbon monoxide poisoning can include headaches dizziness and difficulty in breathing Asphyxiation H Hazard Some p people c cannot s smell w well S S...

Страница 7: ...high limit switch and an air proving switch Never operate this heater with any safety device that has been bypassed Do not operate this heater unless all of these features are fully functioning 6 Do n...

Страница 8: ...mber 23578 4 The heater must have the proper gas regulator installed for the application A regulator must be connected to the gas supply so that gas pressure at the inlet to the gas valve is regulated...

Страница 9: ...Manual Make sure you know how to shut off the gas supply to the building and also to the individual heater Contact your fuel gas supplier if you have any questions 17 Any defects found in performing...

Страница 10: ...chain hanging kit part number 08748 Refer to the following instructions and illustrations 1 Assemble eyebolts and chain according to the illustration and tighten all eyebolts securely See Fig 2 FIG 2...

Страница 11: ...THERMOSTAT GROUND BROWN RED RED YELLOW YELLOW WHITE BLACK WHITE BLACK GREEN 8 9 10 HI LO YELLOW BLUE RED NIPPLE HOSE ADAPTER TEE NIPPLE CAP TO GAS CONTROL...

Страница 12: ...ctrical connection jumper between relays in building control to allow staging transition of gas control valve D Heat V Vent B Building C Control C Connections Using N Non P Powered C Contacts Remove j...

Страница 13: ...er at terminals 1 and 2 Remove black leads at terminals 3 and 4 to selector switch Remove white leads at terminal 6 to selector switch Add neutral s of control contacts at terminal 5 HEAT MODE Add con...

Страница 14: ...4 The direct spark ignition DSI control board within this heater is self diagnostic The board works in conjunction with a light emitting diode L E D built into the selector switch The L E D will flash...

Страница 15: ...Periodic cleaning and inspection as well as proper maintenance are essential to avoid serious injury or property damage 1 The area surrounding the heater shall be kept clear and free from combustible...

Страница 16: ...on FIG 9 AIR PROVING SWITCH Service Instructions 1 Close the fuel supply valve to the heater and disconnect the heater s electrical supply before servicing unless it is necessary to have the valve ope...

Страница 17: ...R AND FLAME SENSOR BLOWER OUTLET OF HEATER AIR PROVING SWITCH ARM OF FLAPPER AIR PROVING SWITCH ARM FANWHEEL PIVOT POINT OF FLAPPER EDGE OF FLAPPER PIVOT POINT OF FLAPPER FLAPPER 31 7 MMTO 34 9 MM 1 E...

Страница 18: ...om the switch which indicates the contacts of the switch have opened Check for lack of electrical continuity across the switch terminals to verify contacts have opened 5 Allow the switch cool down for...

Страница 19: ...let pressure gauges agree with that specified on the dataplate If so then no further checking or adjustment is required Proceed to section D 3 If the inlet pressures do not agree with that specified o...

Страница 20: ...s Page A Motor Does Not Run 24 B Motor Hums Does Not Run 24 Components should be replaced only after each step has been completed and replacement is suggested in the flow chart Refer to the Servicing...

Страница 21: ...Are 24 Volts Supplied from Transformer No No No No No Yes Is Proper Voltage Supplied to Transformer No Yes Yes No See One Time Flash L E D Light is Defective Replace Ignition Control Check Dataplate...

Страница 22: ...ns Yes Repair Air Proving Switch One T T ime Flash P P attern Begins Immediately After C C ondition Occurs Is Air Proving Switch Stuck Closed Check Continuity Is Airflow Switch Binding Repair Yes Yes...

Страница 23: ...Proving Switch No Is Fan Loose On Motor Shaft Yes Tighten Fan Blade Set Screw Is Proper Voltage Supplied to Fan Motor No Yes Defective Motor or Capacitor Replace Motor or Capacitor Is Ignition Module...

Страница 24: ...curs T T he Module H H as Gone i i nto S S afety Lockout Is Proper Fuel Supplied to Heater Inlet Connect Proper Fuel Supply to Heater Open All Gas Shutoff Valves Yes No Is Proper Gas Pressure Supplied...

Страница 25: ...onnections Verify Proper Voltage with a Voltage Tester Contact a Qualified electrician if Proper voltage is not Present No No Yes Is Proper Voltage Supplied to Selector Switch from Power Cord No VENTI...

Страница 26: ...TER MALFUNCTION CHECK FOR PROPER OPERATION AFTER SERVICING WARNING THIS HEATER MAY START AT ANY TIME FAN MOTOR TRANSFORMER AIR PROVING SWITCH BLUE BLUE HIGH VOLTAGE IGNITION LEAD IGNITER FLAME SENSOR...

Страница 27: ...lexible connector used to convey gas from supply line in building to heater Heat Chamber Metal fire box within the heater that provides an area where burner flame mixes with combustion air thereby pro...

Страница 28: ......

Страница 29: ...Switch High Limit 05566 18 Chamber Heat 23566 19 Case Assembly with Doors and Latches 2 20465 20 Latch Assembly 20959 21 Harness Wiring 23534 22 Control Ignition 22461 23 Transformer 120 24 v 81218 2...

Страница 30: ...date o of p purchase by t the e end u user Warranty is automatic if a component is found defective within 12 months of the date code marked on the part If the defect occurs more than 12 months later t...

Отзывы: