Foreman Ductable Dual Fuel Indirect-Fired Heater
Owner’s Manual • Foreman
13
This heater may be ducted using the approved L.B.
White distribution devices:
-- (2) 12 in./30.48 cm Dia. x 25 ft. / 7.62 m duct
kit, L.B. White Part # 30052, duct adapter not
required.
-- (1) 16 in. / 40.64cm Dia. x 25 ft. / 7.62 duct kit,
L.B. White Part #30076. Duct adapter part #30902
is required.
-- Substitute ductwork material is acceptable but
must conform to the following requirements:
1. Duct must have a minimum material temperature
of 300°F/149°C
2. Duct length not to exceed 25 ft. /7.62 m per duct.
-- Locate the duct under suitable wind barrier materi-
als for jobsite requirements.
3. Alternate 12” duct can be used from the following
manufacturer’s:
- Artic Helix - Norseman
- Artic Econorush - Norseman
- Hitex Series - NTI Global
-
Vent
fl
ex Series - NTI Global
NOTE:
■
When using the ducting, ensure that bends in
ducts are kept to a minimum. A maximum of two
90° bends is allowed.
■
Reducing the number of bends will ensure that the
warm air exiting the heater
fl
ows freely, thereby
preventing overheating. If there are excessive
bends, the high limit switches may open.
OPTIONAL:
Air Recirculating Duct Kit, 20 in. /
50.8 cm Dia. x 25 ft. / 7.62m, may be attached to
the heater supply air inlet.
Duct Installation
Содержание Foreman CI500
Страница 37: ...Foreman Ductable Dual Fuel Indirect Fired Heater Owner s Manual Foreman 37 Notes ...
Страница 78: ...Calefactor canalizado doble por combustible indirecto Foreman www lbwhite com Manual del usuario Foreman 36 ...
Страница 79: ...Calefactor canalizado doble por combustible indirecto Foreman Manual del usuario Foreman 37 Notas ...
Страница 84: ......
Страница 127: ......