manualshive.com logo in svg
background image

1-K

Kerosene

Congratulations!

You have purchased the finest kerosene portable forced air construction heater available. 

Your new L.B. White heater incorporates the benefits from the most experienced

manufacturer of heating products using state-of-the-art technology.

We, at L.B. White, 

thank you

for your confidence in our products and welcome any

suggestions or comments you may have...call us, toll-free, at (800) 345-7200.

Owner's Manual and Instructions

Tradesman Kerosene Heaters

ATTENTION ALL USERS

This heater has been tested and evaluated by C.S.A. International in accordance with

the requirements of Standard ANSI A10.10-1990, CAN/CSA B140.87 and CSA

B140.8 - 1967 and is listed and approved as a Kerosene forced-air construction

heater with application for the temporary heating of buildings under construction,

alteration, or repair.  If you are considering using this product for any application

other than its intended use, then please contact the L.B. White Co., Inc.

MODELS

OUTPUT 

(BTUH)

FUEL

CP400AK                

400,000

CP650AK                

650,000

Certification by:

150-26904

Содержание CP400AK

Страница 1: ...Manual and Instructions Tradesman Kerosene Heaters ATTENTION ALL USERS This heater has been tested and evaluated by C S A International in accordance with the requirements of Standard ANSI A10 10 199...

Страница 2: ...rborne combustibles include gasoline solvents paint thinner dust particles or unknown chemicals Failure to follow these instructions may result in a fire or explosion Fire or explosions can lead to pr...

Страница 3: ...s all options and accessories commonly used on this heater When calling for technical service assistance or for other specific information always have model number configuration number and serial numb...

Страница 4: ...trical Supply Voltz Hz Phase 120 60 1 4 4 7 1 Dimensions Inches Length x width x height 52 5 x 32 x 34 69 2 x 30 7 x 48 7 TOP 4 ft SIDES 4 ft BACK 4 ft BLOWER OUTLET 8 ft BULK FUEL STORAGE CONTAINER 2...

Страница 5: ...result in minor or moderate injury WARNING Before using this heater please read this USER S MANUAL very carefully This USER S MANUAL has been designed to instruct you as to the proper manner in which...

Страница 6: ...e heater is equipped with a thermostat the heater may start at any time ALWAYS locate heater on a stable and level surface Use 1 K kerosene in this heater 1 fuel oil is a suitable substitute Bulk fuel...

Страница 7: ...all packing items applied to heater for shipment 2 Remove all items from carton 3 Check all items for shipping damage If heater is damaged promptly inform dealer where you purchased heater DIMENSIONS...

Страница 8: ...eater on wheel support frame Make sure air inlet end rear of heater is over wheels Align the holes on fuel tank flange Insert screws through handles front and rear fuel tank flange and wheel support f...

Страница 9: ...Figure 5 Heater Dimensions 48 7 69 2 30 7 Figure 6 Model CP650AK Features Handle Supporter Hot Air Outlet Lower Shell Fuel Gauge Fuel Cap Lamp Thermostat Knob Power Reset Switch Power Cord Drain Plug...

Страница 10: ...t washers and cotter pins on axle ends and bend cotter pins with long nose pliers to secure 3 Place wheel cap on flat washers and put wheel cap in flat washers end 4 Loosen 4 screws on the front handl...

Страница 11: ...Control designed to turn the heater off should the internal temperature rise to an unsafe level If this device activates and turns your heater off it may require service Electrical System Protection T...

Страница 12: ...ratures Whenroomtemp ismorethan99 F HI NOTE The major electrical components of this heater are protected by a circuit breaker mounted to the power switch If your heater fails to start check this first...

Страница 13: ...ou remove it all IMPORTANT Do not store kerosene over summer for use during next heating season Using old fuel may damage heater 3 Reinstall drain plug as follows Insert plug s seal head fully into dr...

Страница 14: ...fan blades and air deflectors using soft cloth moistened with kerosene or solvent Dry fan blades and air deflectors thoroughly Reinstall upper shell 4 14 MAINTENANCE USE ORIGINAL EQUIPMENT REPLACEMEN...

Страница 15: ...into burner head and tighten firmly 175 200 inch pounds Reinstall spark plug into burner head Attach burner head to combustion chamber Attach spark plug wire to spark plug Attach fuel line to solenoid...

Страница 16: ...CLEAN TWICE PER HEATING SEASON OR AS NEEDED Tank Fuel Filter Remove fan guard See Figure 21 22 Disconnect fuel line B from pump and pump fuel filter assembly with 3 8 wrench See Figure 23 Carefully p...

Страница 17: ...2 Allow motor to reach full speed Adjust pressure Using small flat blade screwdriver Turn pressure adjustment screw clockwise to increase pressure Turn screw counterclockwise to decrease pressure Set...

Страница 18: ...4 18 WIRING DIAGRAM ORANGE BLACK Figure 27 Wiring Diagram Model CP650AK Figure 26 Wiring Diagram Model CP400AK...

Страница 19: ...rical connection between motor and MAIN PCB assembly 1 Room Temp sensor disconnected 2 Sensor failure Thermostat switch failure 1 Temperature limit safety device is overheated 2 No electrical power 3...

Страница 20: ...er Serial number if any Part description and number as shown in parts list Figure 28 Repair Parts Illustration for Portable Oil Fired Heaters Models CP400AK PARTS SCHEMATIC CP400AK Parts Identificatio...

Страница 21: ...Ignition Transformer 572299 12 Ignition Transformer Cover 572247 13 Burner Harness 572291 14 Combustion Chamber 572182 15 Temperature Limit Control 572297 16 Air Deflectors Qty 5 572295 17 Photocell...

Страница 22: ...ber Serial number if any Part description and number as shown in parts list Figure 29 Repair Parts Illustration for Portable Oil Fired Heaters Models CP650AK PARTS SCHEMATIC CP650AK Parts Identificati...

Страница 23: ...572300 11 Ignition Transformer Cover 572247 12 Burner Harness 572292 13 Combustion Chamber 572183 14 Temperature Limit Control 572298 15 Air Deflectors Qty 5 572296 16 Photocell Bracket 572185 17 Pho...

Страница 24: ...er as shown in parts list Figure 30 Burner head for CP400AK CP650AK PARTS SCHEMATIC BURNER HEAD CP400AK 650AK Parts Identification 4 24 2 1 3 5 4 1 Burner Head 572305 2 Nozzle Assembly 572197 572198 3...

Страница 25: ...K CP650AK PARTS SCHEMATIC MOTOR ASSEMBLY CP400AK 650AK Parts Identification 4 25 5 2 1 3 4 6 8 9 7 1 Motor 572212 572213 2 Motor Support 572221 572222 3 Motor Hardware Kit 572310 4 Fuel Pump 572306 57...

Страница 26: ...and number as shown in parts list Figure 32 Handle wheels assembly CP400AK PARTS SCHEMATIC HANDLE WHEELS ASSEMBLY CP400AK Parts Identification 4 26 3 2 1 4 5 1 Wheel Support Axle Kit 572316 2 Upper Ha...

Страница 27: ...description and number as shown in parts list Figure 33 Handle wheels assembly CP650AK PARTS SCHEMATIC HANDLE WHEELS ASSEMBLY CP650AK Parts Identification 2 1 3 4 1 Wheel Support Axle Kit 572321 2 Whe...

Страница 28: ...the end user Warranty is automatic if a component is found defective within 12 months of the date code marked on the part If the defect occurs more than 12 months later than the date code but within 1...

Страница 29: ...Appareil de chauffage portatif pulsion d air Tradesman Certifi par ATTENTION TOUS LES UTILISATEURS Cet appareil a t test et valu par le C S A International selon les normes en vigueur ANSI A10 10 199...

Страница 30: ...substances chimiques d origine inconnue sont autant de substances volatiles ou de combustibles en suspension Le non respect de ces consignes peut entrainer un incendie ou une explosion Un incendie ou...

Страница 31: ...assistance technique assurez vous d avoir en votre possession le num ro de mod le et de configuration de l appareil ainsi que son num ro de s rie Vous trouverez cette information sur la fiche signal...

Страница 32: ...M Sp cifications lectriques Volts Hz Phase 120 60 1 4 4 7 1 Dimensions Centimeters L x W x H 133 4 x 81 3 x 86 4 175 8 x 78 0 x 123 7 DESSUS 125 cm COTES 125 cm ARRIERE 125 cm ORIFICE DE SORTIE DU VEN...

Страница 33: ...Ne jamais laisser le radiateur sans surveillance s il fonctionne DANGER L utilisation inappropri e de ce radiateur peut causer des blessures graves ou mortelles suite des br lures un incendie une exp...

Страница 34: ...d autres par le monoxyde de carbone Elles comprennent les femmes enceintes les personnes souffrant des probl mes de c ur ou de poumons d an mie sous l influence de l alcool ou des altitudes lev es S...

Страница 35: ...r est endommag informer imm diatement le d taillant qui vous l a vendu Figure 1 Dimensions du radiateur 86 4 cm 133 4 cm 81 3 cm Figure 2 Caract ristiques du mod le CP400AK Poign e avant Sortie d air...

Страница 36: ...uis ce capuchon sur l extr mit des rondelles plates 4 Placer le radiateur sur le cadre de support de roue S assurer que l entr e d air arri re du radiateur est par dessus les roues Aligner les trous s...

Страница 37: ...re Jauge combustible Bouchon de combustible Voyant Bouton du thermostat Interrupteur d alimentation r enclenchement Cordon d alimentation Bouchon de vidange Protection de ventilateur Enveloppe sup rie...

Страница 38: ...tre vis de la poign e avant pour la d poser 5 D placer l avant de la poign e d pos e vers la poign e du c t avant comme l indique la Figure 8 et serrer les quatre vis apr s avoir appari la poign e ave...

Страница 39: ...no 1 ou no 2 diesel si du k ros ne 1 K n est pas disponible Prendre note que ces combustibles ne br lent pas aussi proprement que le k ros ne 1 K et qu il faut s assurer d accro tre la ventilation d...

Страница 40: ...ur de commande lectrique Si le radiateur ne d marre pas v rifier d abord cet l ment et le remplacer le cas ch ant Il faut galement v rifier la source d alimentation pour s assurer que la bonne tension...

Страница 41: ...t de niveau avec la collerette de la t te Voir la Figure 13 IMPORTANT R installer le bouchon compl tement dans le r servoir sinon il ne permettra pas une tanch it compl te S assurer que le lieu d entr...

Страница 42: ...de combustible de l lectro valve en utilisant une cl de 1 4 po D brancher le fil de bougie de la bougie Enlever la bougie d allumage de la t te de br leur en utilisant un tournevis Phillips de taille...

Страница 43: ...ible A au niveau de l lectro valve et de la pompe voir la Figure 20 D poser la protection du ventilateur voir la Figure 21 22 Utiliser une cl de 3 8 po et serrer la canalisation de combustible B au ni...

Страница 44: ...r Filtre combustible de la pompe D poser la protection du ventilateur voir la Figure 21 22 D visser la partie inf rieure du filtre en tournant le sens horaire partir de la partie sup rieure du filtre...

Страница 45: ...ler la pression de la pompe 861 9 kPa 125 lb po2 CP400AK R gler la pression de la pompe 758 5 kPa 110 lb po2 CP650AK Arr ter le radiateur voir Fonctionnement page 12 D poser le manom tre Remettre le b...

Страница 46: ...ur 45 F 450 V c a lectro valve Allumeur Moteur de pompe Bougie d allumage CN7 CN4 CN3 CN2 AC2 Blanc CN1 AC1 Noir Noir Blanc CN5 CN6 Figure 27 Sch ma de c blage du mod le CP650AK Thermostat Commande de...

Страница 47: ...Panne de capteur D faillance de l interrupteur du thermostat 1 Le dispositif de s curit de temp rature limite a surchauff 2 Pas d alimentation lectrique 3 Mauvaise connexion lectrique entre le disposi...

Страница 48: ...6 8 7 5 4 3 2 1 13 12 24 26 15 17 28 10 29 Sch ma de Parties CP400AK Identification de Parties Commandez les pi ces d tach es en appelant gratuitement 1 800 345 7200 S il vous pla t fournir l informat...

Страница 49: ...11 Allumeur 572299 12 Couvercle d allumeur 572247 13 Faisceau du bruleur 572291 14 Chambre 572182 15 Commande de limite de temperature 572297 16 deflecteur d air Quantit 5 572295 17 Support de cellul...

Страница 50: ...pla t fournir l information suivante Num ro de mod le Num ro de s rie s il y en a un Description de la pi ce et son num ro comme montr sur la liste de pi ces 5 6 7 23 8 4 2 3 1 10 11 12 24 27 14 16 1...

Страница 51: ...2300 11 Couvercle d allumeur 572247 12 Faisceau du bruleur 572292 13 Chambre 572183 14 Commande de limite de temperature 572298 15 deflecteur d air Quantit 5 572296 16 Support de cellule photoelectriq...

Страница 52: ...t son num ro comme montr sur la liste de pi ces Figure 30 Tete du Bruler CP400AK CP650AK 2 1 3 5 4 1 Tete de Bruleur 572305 2 Assemblage d ajutage 572197 572198 3 Bougie d allumage 572201 572203 4 Ele...

Страница 53: ...72216 572217 8 Filtrez pompez des essayages 572313 9 Support de condensateur 572250 Ref Part No for Models No Description CP400AK CP650AK Commandez les pi ces d tach es en appelant gratuitement 1 800...

Страница 54: ...oulement du cordon 572318 Ref Part No for Models No Description CP400AK Commandez les pi ces d tach es en appelant gratuitement 1 800 345 7200 S il vous pla t fournir l information suivante Num ro de...

Страница 55: ...un Description de la pi ce et son num ro comme montr sur la liste de pi ces Sch ma de Parties Poignee Roues CP400AK CP650AK Identification de Parties Figure 33 Poignee Roues CP650AK 2 1 3 4 1 Kit de...

Страница 56: ...ode de douze 12 mois calcul e partir de l achat de la pi ce par l utilisateur final La garantie s applique automatiquement si une pi ce s av rait d fectueuse l int rieur d une p riode de 12 mois d but...

Отзывы: