SB18_UM_ML_1-0
w w w . l - a c o u s t i c s . c o m
21
21
21
21 en
EN
8.3.5
Transducer
Replacement kit and tools
KR HPBC182, electric screwdriver with torque selector (N.m or in.lb
f
), T30 Torx
®
bit, 5 mm hex bit, KR LOCKBLUE.
Transducer removal procedure
1.
Remove the front face [8.3.2,
Front face removal procedure
].
2.
Remove the front bass-reflex panel by removing the 10 Torx
®
screws (T30 bit) and then remove the joint
surrounding the panel location on the enclosure.
3.
Remove the transducer by removing the 8 hex screws with split and flat washers (5 mm hex bit).
Pay attention
no to bend the terminals
.
4.
Disconnect both red and black cables from the transducer’s electrical sockets (press the spring-loaded tab, slide
the cable out, and release the tab).
5.
Remove the joint surrounding the transducer location on the enclosure.
Transducer mounting procedure
1.
Put joint around the transducer location on the enclosure.
2.
Connect the red cable to the transducer’s red terminal and the black cable to the black terminal
(press
the spring-loaded tab, slide the cable in, and release the tab).
3.
Install the transducer in the enclosure (
pay attention no to bend the terminals
) and screw in eight 30 mm hex
screws with split and flat washers (5 mm hex bit, 5 N.m/45 in.lb
f
): into each hex screw insert a split washer and
then a flat washer (
follow this sequence
) and screw in the assembly.
4.
Put joint around the bass-reflex panel location on the enclosure.
5.
Install the front bass-reflex panel in the enclosure and screw in ten 35 mm flat head Torx
®
screws (thread-locker,
T30 bit, 7 N.m/63 in.lb
f
).
6.
Install the front face on the enclosure [8.3.2,
Front face mounting procedure
].
8.3.6
Connector plate
Replacement kit and tools
KR CNTXTI, electric screwdriver with torque selector (N.m or in.lb
f
), T30 Torx
®
bit, 5 mm hex bit, KR LOCKBLUE.
Connector plate removal procedure
1.
Remove the transducer [8.3.5,
Transducer removal procedure
].
2.
Remove the 4 Torx
®
screws (T30 bit) from the connector plate and remove the connector plate.
Connector plate mounting procedure
1.
Install the connector plate on the enclosure and screw in four 35 mm flat head Torx
®
screws (thread-locker, T30
bit, 3 N.m/27 in.lb
f
).
2.
Mount the transducer [8.3.5,
Transducer mounting procedure
].